Installation instructions
3.3.3Venting configuration examples
Below are approved examples of horizontal venting installations.
4"
HORIZONTAL RUN |
1/4" PERFOOT |
DOWN TO |
TERMINATOR. |
CONDENSATE
DRAIN
Fig. 13 Horizontal side wall venting installation (single pipe penetration)*
* Warning: for
Fig. 15 Horizontal twin pipe penetration
Below are approved examples of vertical venting installations.
Important:
Note: Pitch horizontal runs down toward the heater, 1/4" per foot.
Note: Pitch horizontal runs down toward the heater, except horizontal run between last elbow and termina- tion which must slope down to termination 1/4" per foot.
Note: For horizontal terminations, venting must terminate once it penetrates to the outside of the structure. There must be no sections of vent pipe exposed to the outdoors.
12"
Min. 3 Feet
3” stainless steel pipe
10'MIN. |
2'MIN.
3'MIN.
FIRESTOP SUPPORT
FIRESTOP SUPPORT
HOSE
CLAMP
ELBOW
CONDENSATE
DRAIN
APPLIANCE
RAINCAP
STORMCOLLAR
FLASHING
4"MIN.
AIRSPACE
Fig. 14 Horizontal venting installation (concentric penetration)
Fig. 16 Vertical venting installation (single pipe pene- tration)*
* Warning: for
14 | 6 720 608 542 |