Bosch Appliances GWH 2700 ES LP, ESVVT manual Mineral scale build-up, Adjusting CO2 carbon dioxide

Page 33

Maintenance and service

space which is likely to experience freezing temperatures, all water must be drained from the heater. If precautions are not taken, resulting damage will not be covered under the warranty. NOTE: Use of agents such as anti-freeze is not permitted as they may cause damage to the water heater's internal components.

1.Press ON/OFF switch on the water heater to turn OFF the heater and unplug power supply cord. The display should be blank.

2.Shut off gas supply to heater.

3.Shut off the water supply to the water heater using installer supplied shutoff valve.

4.Open hot water taps to drain the plumbing system. If water continues to flow after 5 minutes, a plumbing crossover is present and must be corrected before proceeding.

5.Open service valves (if available) or disconnect inlet and outlet water pipes from the water heater. Place a small bucket underneath the water heater to catch residual water remaining inside the water heater.

6.Using an air compressor, blow short bursts of air (100psi max) through the outlet water connection until there is no water present coming through the inlet water connection of the heater.

7.Reconnect water fittings and return heater to service when danger of freezing has past.

6.3Mineral scale build-up

Periodic descaling may be necessary in areas with high mineral content in the water. Scale buildup in the heat exchanger may result in lower flow rates, error codes of A7 and E9 and boiling sounds (knocking and banging) in the heat exchanger.

Descaling using a pump

1.Disconnect electrical supply from the water heater.

2.Shut off the water supply to the water heater using (installer supplied) shutoff valve.

3.Open hot water taps to drain and relieve pressure from the plumbing system.

4.Drain water from the unit's heat exchanger by disconnecting inlet and outlet water connections from the heater.

5.Connect a line (A) from the outlet of the circulating pump (installer supplied) to the inlet water fitting on the water heater (see Fig. 54).

6.Using another line (B), connect to the water outlet fitting on the water heater. Route the other end of this line into a descaling reservoir.

7.Using a 3rd line (C) from the descaling reservoir, connect to the inlet side of circulating pump. Install a filter on the end of this line in the descaling reservoir.

8.Make sure all connections are "water tight.".

9.Fill tank with descaling solution so both lines inside are submersed. We recommend straight white vinegar. If using a commercial descalant, refer to manufacturer's instructions on dilution with water.

10.Operate the circulating pump.

11.Make sure there are no leaks and the solution is flowing from the descaling reservoir through the heater and returning to the reservoir.

12.Run solution through the heater until the solution returning to the descaling reservoir comes out clear. (Changing to a fresh solution may be necessary during this process).

13.Disconnect all lines and drain all solution from heat exchanger. Properly discard of solution.

14.Position a container below the hot water outlet and connect cold water supply. Open cold water supply isolation valve and flush heat exchanger with clean water.

15.Shut cold water shutoff valve and reconnect hot water supply to the water heater.

16.Reconnect electrical supply to unit, open water shutoff valves, and return the unit to service.

Fig. 54

6.4Adjusting CO2 (carbon dioxide)

The CO2 can only be adjusted by a certified gas technician with a calibrated CO2 analyzer.

Caution: One factor that may affect CO2 levels is improper gas pressure. Please see Chapter 3.12 for the procedure to measure gas pressure and record your findings below:

6 720 608 542

33

Image 33
Contents What to do if you smell gas Intended for variable flow applicationsIndex For your safety Appliance details FeaturesSpecifications Technical data To remove combustion cover service only Unpacking the heaterGWH 2700 ES is not approved or designed for Venting General rules to follow for safe operationDimensions Dimensions and Minimum installation clearancesTools required for installation Installation instructionsIntroduction VentingInstallation instructions Horizontal venting systems only Venting SpecificationsFittings or Piping Equivalent Feet Twin pipe termination clearances Installation instructions Condensate drain requirementsMinimum combustion air and exhaust pipe length Maximum combustion air and exhaust pipe lengthCanadian installations1 Installations2 Canadian installations1 Horizontal twin pipe penetration Vent connections Vertical venting installation twin pipe penetra- tionVenting Flex ProTech Heat Fab Installation instructions Condensate drain installationExhaust Total equivalent vent length calculationIntake ExampleAdjusting minimum power fan speed P2 Adjusting maximum power fan speed P1Level Vent length1 Speed P2 Installation instructions Twin pipe and Concentric pipe Combustion air requirementsProper location for installing your heater Heater placement and clearancesMounting installation Gas piping & connections GAS Line Sizing For Natural GAS Water quality Water connectionsGWH Domestic hot water recirculationMeasuring gas pressure Connecting manometerStatic Pressure Test Operating Pressure TestElectrical power supply Electrical connectionsPosition of the fuses in control unit LCD Display functions Operation instructionsFor your safety read before operating your water heater PowerTemperature selection Reset button Use of optional remote control Accessory part no. TSTAT2Operation Program buttonAnnual maintenance table Every year Maintenance and serviceAnnual maintenance Winterizing for seasonal useAdjusting CO2 carbon dioxide Descaling using a pumpMineral scale build-up Adjusting CO2 Measuring CO2 combustion cover must be installedReturning to Service Once Gas Pressure is adequate% 3.0 % 60 ppm Final ReadingsProgram Description Factory Default Program valuesComment Diagnostic menu Control board diagnosticsTroubleshooting TroubleshootingWater is too hot Water is not hot enoughHot water temperature fluctuates at tap Low water flow/pressureNoisy burner/heater during operation Lack of adequate gas pressure. Inadequate gas Error code diagnostics Problem solvingVenting may cause this failure Problem solving Display Cause SolutionOver-temperature detected by No flame ionization detected with Electrical diagram Electrical diagramSensor resistance charts Back Flow characteristics Functional scheme GWH 2700 ES Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Appliance overview Components diagram GroupDescription Reference Interior components diagram and parts list Group 1211 6720608158-73.1AL Interior components diagram and parts list Group 708 300 Protecting the environment Protecting the environmentPacking ComponentsLimited Warranty Limited Warranty 6720608542