14 Limited Warranty

General

Aquastar water heaters are warranted by the

Manufacturer (BOSCH) through Bosch Thermotechnology Corp..

Bosch thermotechnology corporation will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicable periods specified below, in accordance with the terms of this warranty. The Bosch Thermotechnology Corp. replacement will be warranted for the unexpired portion of the original warranty. This warranty will be valid only for water heaters in possession of the original purchaser as recorded on the warranty card.

The Heat Exchanger

If the heat exchanger fails within twelve (12) years after the original installation and operation, Bosch Thermotechnology Corp. will furnish a replacement heat exchanger. However, if the water heater is used within an approved hot water recirculation and supplied with circulated water, this heat exchanger warranty is limited to three (3) years from date of original installation and operation. If the water heater is installed in other than a single family dwelling, this heat exchanger warranty is limited to two (2) years from date of original installation and operation.

Exceptions

This warranty will not apply:

1. to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided;

2. to damage or abuse, accident, neglect or freezing and other acts of nature;

3. to damage resulting from operation with either the flame sensor rod or overheat sensor removed;

4. to failure of the heat exchanger resulting from the operation of the water heater in a corrosive atmosphere or at water temperatures exceeding the maximum rating, or if the water heater is not supplied with potable water;

5. to defects or damage cause by any attachment or modification, including any energy-saving device.

6. to damage resulting from scale deposits and/or highly mineralized / unsoftened water supply.

All Other Parts

If any other part fails within five (5) years after original installation and operation, Bosch Thermotechnology Corp. will furnish a replacement part free of charge.

Service Labor Costs

This warranty does not cover any labor costs associated with service, removal or re-installation of part(s). All such costs must be borne by the Purchaser. Additionally, this warranty does not cover any labor costs associated with service, removal, installation or re-installation of the original water heater or a replaced water heater.

NOTE: the water heater must be free of

idamaging scale deposits and not subject to gas pressures greater than those shown on the rating plate, which must not be altered, defaced or removed.

How to Make a Claim

Any claim for warranty parts should be made to your local dealer or distributor:

BOSCH THERMOTECHNOLOGY CORP.

340 Mad River Park Waitsfield, VT 05673 TEL. 800-642-3111 www.boschhotwater.com

In most cases, the dealer or distributor will be able to promptly honor your claim and subsequently notify Bosch Thermotechnology Corp.. However, all replacements are made subject to validation by Bosch Thermotechnology Corp. of in-warranty coverage. The damaged or defective item must be made available in exchange for the replacement.

Miscellaneous

No one is authorized to make any other warranties on behalf of Bosch Thermotechnology Corp.. It is expressly understood that the replacement warranty of Bosch Thermotechnology Corp. shall be in lieu of any and all other warranties, express or implied, including warranties of merchantability or fitness for a particular use or purpose, and further that Bosch Thermotechnology Corp. shall not be liable for any loss or damage directly or indirectly arising from the use of the hot water heater, or for any consequential damages arising from such use (including damages from water leakage). Bosch Thermotechnology Corp. sole liability with respect to any defect shall be for the replacement of the defective part(s). Some states do not allow such limitations and exclusions, so the above may not apply to you.

This warranty gives specific legal rights. You may also have other rights which vary from state to state.

58

6 720 608 542

Image 58
Contents Intended for variable flow applications What to do if you smell gasIndex For your safety Features Appliance detailsSpecifications Technical data Unpacking the heater To remove combustion cover service onlyGWH 2700 ES is not approved or designed for General rules to follow for safe operation VentingDimensions and Minimum installation clearances DimensionsIntroduction Installation instructionsTools required for installation VentingVenting Specifications Installation instructions Horizontal venting systems onlyFittings or Piping Equivalent Feet Minimum combustion air and exhaust pipe length Installation instructions Condensate drain requirementsTwin pipe termination clearances Maximum combustion air and exhaust pipe lengthCanadian installations1 Installations2 Canadian installations1 Horizontal twin pipe penetration Vertical venting installation twin pipe penetra- tion Vent connectionsInstallation instructions Condensate drain installation Venting Flex ProTech Heat FabIntake Total equivalent vent length calculationExhaust ExampleAdjusting maximum power fan speed P1 Adjusting minimum power fan speed P2Level Vent length1 Speed P2 Installation instructions Combustion air requirements Twin pipe and Concentric pipeHeater placement and clearances Proper location for installing your heaterMounting installation Gas piping & connections GAS Line Sizing For Natural GAS Water connections Water qualityDomestic hot water recirculation GWHStatic Pressure Test Connecting manometerMeasuring gas pressure Operating Pressure TestElectrical connections Electrical power supplyPosition of the fuses in control unit Operation instructions LCD Display functionsPower For your safety read before operating your water heaterTemperature selection Operation Use of optional remote control Accessory part no. TSTAT2Reset button Program buttonAnnual maintenance Maintenance and serviceAnnual maintenance table Every year Winterizing for seasonal useDescaling using a pump Adjusting CO2 carbon dioxideMineral scale build-up Returning to Service Measuring CO2 combustion cover must be installedAdjusting CO2 Once Gas Pressure is adequateFinal Readings % 3.0 % 60 ppmProgram values Program Description Factory DefaultComment Control board diagnostics Diagnostic menuWater is too hot TroubleshootingTroubleshooting Water is not hot enoughLow water flow/pressure Hot water temperature fluctuates at tapNoisy burner/heater during operation Lack of adequate gas pressure. Inadequate gas Problem solving Error code diagnosticsProblem solving Display Cause Solution Venting may cause this failureOver-temperature detected by No flame ionization detected with Electrical diagram Electrical diagramSensor resistance charts Back Flow characteristics GWH 2700 ES Functional scheme Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Appliance overview Group Components diagramDescription Reference Interior components diagram and parts list Group 1211 6720608158-73.1AL Interior components diagram and parts list Group 708 300 Packing Protecting the environmentProtecting the environment ComponentsLimited Warranty Limited Warranty 6720608542