Bosch Appliances GWH 2700 ES LP Unpacking the heater, GWH 2700 ES is not approved or designed for

Page 6

Appliance details

2.3Unpacking the heater

Before installing the unit, be certain you have the correct heater for your type of Gas: Propane or Natural Gas. Identification labels are found on the shipping box, and on the rating plate which is located on the right side panel of the cover.

To remove front cover

B Loosen the two Philips head screws located on bottom rear of cover (see Fig. 3).

Fig. 2 Rating plate

ASerial number

B Type of gas

The box includes:

GWH 2700 ES

Pressure relief valve (150 psi / 200,000 Btu rating)

Bracket for wall hanging the heater

Exhaust vent adaptor (with 4 screws and gasket provided)

Combustion air inlet adaptor (with 3 screws and gas- ket provided)

Installation manual (manual can be downloaded at www.boschhotwater.com)

Product registration card

Energy Guide label.

Please complete and return the enclosed product registration card.

The GWH 2700 ES is not approved or designed for:

Manufactured (mobile) homes, boats or any mobile installation (modular homes are acceptable for installation)

Use above 8000 ft A.S.L. altitude (see page 18)

Outdoor installation without installation of Outdoor kit (AQOK)

Space heating purposes

Preheated inlet water supply.

Fig. 3 Loosen the two screws

BLift front cover panel upward and remove.

Fig. 4 Removing the front cover

To remove combustion cover (service only)

B Open the four clips and remove the combustion cover see Fig. 5.

Fig. 5 Remove the combustion cover

6

6 720 608 542

Image 6
Contents Intended for variable flow applications What to do if you smell gasIndex For your safety Features Appliance detailsSpecifications Technical data To remove combustion cover service only Unpacking the heaterGWH 2700 ES is not approved or designed for General rules to follow for safe operation VentingDimensions and Minimum installation clearances DimensionsIntroduction Installation instructionsTools required for installation VentingInstallation instructions Horizontal venting systems only Venting SpecificationsFittings or Piping Equivalent Feet Minimum combustion air and exhaust pipe length Installation instructions Condensate drain requirementsTwin pipe termination clearances Maximum combustion air and exhaust pipe lengthCanadian installations1 Installations2 Canadian installations1 Horizontal twin pipe penetration Vertical venting installation twin pipe penetra- tion Vent connectionsInstallation instructions Condensate drain installation Venting Flex ProTech Heat FabIntake Total equivalent vent length calculationExhaust ExampleAdjusting minimum power fan speed P2 Adjusting maximum power fan speed P1Level Vent length1 Speed P2 Installation instructions Combustion air requirements Twin pipe and Concentric pipeProper location for installing your heater Heater placement and clearancesMounting installation Gas piping & connections GAS Line Sizing For Natural GAS Water connections Water qualityDomestic hot water recirculation GWHStatic Pressure Test Connecting manometerMeasuring gas pressure Operating Pressure TestElectrical power supply Electrical connectionsPosition of the fuses in control unit Operation instructions LCD Display functionsFor your safety read before operating your water heater PowerTemperature selection Operation Use of optional remote control Accessory part no. TSTAT2Reset button Program buttonAnnual maintenance Maintenance and serviceAnnual maintenance table Every year Winterizing for seasonal useAdjusting CO2 carbon dioxide Descaling using a pumpMineral scale build-up Returning to Service Measuring CO2 combustion cover must be installedAdjusting CO2 Once Gas Pressure is adequateFinal Readings % 3.0 % 60 ppmProgram Description Factory Default Program valuesComment Control board diagnostics Diagnostic menuWater is too hot TroubleshootingTroubleshooting Water is not hot enoughHot water temperature fluctuates at tap Low water flow/pressureNoisy burner/heater during operation Lack of adequate gas pressure. Inadequate gas Problem solving Error code diagnosticsProblem solving Display Cause Solution Venting may cause this failureOver-temperature detected by No flame ionization detected with Electrical diagram Electrical diagramSensor resistance charts Back Flow characteristics GWH 2700 ES Functional scheme Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Appliance overview Components diagram GroupDescription Reference Interior components diagram and parts list Group 1211 6720608158-73.1AL Interior components diagram and parts list Group 708 300 Packing Protecting the environmentProtecting the environment ComponentsLimited Warranty Limited Warranty 6720608542