Bradford-White Corp PDV100S200, D80T725 Pressing Select button will change display to next mode

Page 9

ACCESSING SERVICE MODE ON THE WATER HEATER DISPLAY (FOR SERVICE PERSONNEL ONLY)

The display has a “service mode” for changing the maximum setpoint and accessing information in aiding servicing of the water heater. This procedure is for service and installation personnel only. To enter the Service Mode, follow the steps illustrated below:

Step 1: Press “Select” and “Temperature Up” buttons together and hold for 3 seconds until “Max Setpoint” is shown in the

display.

"Max Setpoint”

 

next to Temperature

 

Setpoint value.

Max

Setpoint

idle

Statu Operational s

SELECTSET

Step 2: Pressing “Select” button will change display to next mode

°F Water

Temp

idle

Status Operational

SELECTSET

The following is the sequence of modes available in “Service Mode” by pressing the “Select” button:

Error Code Number (Display/Reset). This is only shown if there is an operating error in the “User Mode”.

Error Code Shown

in Water Heater Display

Status Service Needed

SELECT Lockout RESET

9

Image 9
Contents Service Manual Table of Contents Features of PDV-T Model Series Features of PDV-S Model SeriesFeatures of Induced Draft Models Features of Honeywell Integrated Controls SystemTools Required for Service Specifications Sequence of Operation Verify Primary and Secondary voltage at the control board TroubleshootingError code #63 on display. See Main Burner short Pressing Select button will change display to next mode Max Setpoint Display/Change Setpoint Display/Change Software Version Display only SET Display of Water Temperature ExitingSELECTServiceSETModeTo Display Flame Sense Current of the Pilot Flame Sensor To Display and Change Temperature SetpointSetpoint Flashes Idle Status Operational Select SET Error Code History Error Codes and Error History DisplayTo view previous error codes ExitingSELECTServiceSETMode Error Code Definitions Resetting Error Codes in Hard Lockout Condition Unplug or disconnect electrical power to the water heater Service Procedure PDV24-IService Procedure PDV24-I Lower Sensor Upper SensorService Procedure PDV23-II Service Procedure PDV24-II Service Procedure PDV24-II Condition Service Procedure PDV24-IIICondition Error code 57 Flame Rod Shorted To Ground Probe To control board Service Procedure PDV24-IVCorrect improper venting condition Manifold Pressure Port PDV S&T Models Service Procedure PDV24-VPDV S&T Models PDV S&T Models Main Burner Removal Induced Draft ModelsPilot Burner Inspection Pilot Burner RemovalService Procedure PDV24-VI Control board replacementRemove lower sensor Service Procedure PDV24-VII Service Procedure PDV24-VIII PDV-S PDV S PDV-S PDV-T PDV T PDV-T Induced Draft Models Induced Draft Models Induced Draft Models CO2 BTU/HECO GFI