SERVICE PROCEDURE ED-I

Burner and Inner Door/Gasket Removal,

Inspection, Replacement and

Reinstallation

Inner Door Gasket Replacement

Procedure.

WARNING

If the information in these instructions is not

followed exactly, a fire or explosion may result causing

property damage, personal injury or death.

Step 5. After inspection of inner door as noted in step 4, completely remove gasket and adhesive residue from burner and left side inner doors as needed.

Step 6. Use RTV sealant (recommended bead size 1/8") to secure the inner door gasket to the inner door sections (right & burner). The burner door gasket must be sliced in the location shown on the illustration below in order to slide the gasket over the burner venturi. Refer to illustration below for proper RTV sealant application. Note the overlap configuration in the flange area of the inner door. Set the flange section first, this will help to achieve the proper over lap position.

Installation of Inner Door With Gasket.

 

Step 7.

Clean any residual gasket residue or other debris

WARNING

 

from combustion chamber surface before

 

Stripped fastener connections may allow

 

installing the inner door/gasket assembly.

Step 8.

Place the burner door into position first. Tighten

for seal breach of inner door. A seal

breach may result in a fire or explosion

 

the feed line nut to the gas valve. Use the ¼” hex

causing property damage, personal injury

 

drive screw without the built-in washer to secure

 

or death. Do not over tighten screws in

 

the right side of the burner door to the chamber.

 

Use the ¼” hex drive screws with the built-in

steps 8, 10 and 11.

 

washer to secure the left side of the burner door in

 

 

place. DO NOT OVER TIGHTEN SCREWS.

If a fastener connection is stripped,

Step 9.

Position thermopile wires, pilot tube and igniter wire

contact the manufacturer listed on the

 

against burner door flange gasket.

water heater rating plate.

 

Page 8

 

8

Image 8
Contents Bradford White Bradford White Introduction How to Use This Manual Probable Cause Service Procedure LED StatusDamage to Thermowell wire Inner Door Removal Procedure Inner Door Gasket Replacement Procedure Place. do not Over Tighten ScrewsPosition Thermopile Wire Pilot Tube and Igniter Wire Closed Circuit Thermopile Testing Honeywell Control Open Circuit Thermopile TestingThermopile Replacement PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement IGNITER, Electrode Testing and Replacement Thermal Well Testing Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Assembly to Thermal Well Chamber Sensor Testing Temperature Range oF Resistance Range kOhmsMain Burner Inspection Cleaning and Replacement Burner CleaningBurner Cleaning Resettable Thermal Switch Continuity Testing Resettable Thermal Switch Replacement Do not Over Tighten ScrewsScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

U130T*FRN, Eco Defender specifications

Bradford-White Corp is a leading name in the water heating industry, known for its commitment to quality and innovation. One of its standout products is the U130T*FRN Eco Defender, a water heater that combines advanced technologies with user-focused design.

The U130T*FRN Eco Defender is a high-efficiency residential water heater that offers various features aimed at maximizing both performance and energy savings. One of its key characteristics is its environmentally friendly operation. This model meets stringent energy efficiency standards, making it an excellent choice for eco-conscious homeowners looking to minimize their carbon footprint. The Eco Defender serves not only to heat water but also to deliver an energy-efficient solution that can contribute to lowering utility bills.

Equipped with a durable design, the U130T*FRN features a robust tank constructed from high-grade steel, complemented by a glass lining that helps prevent corrosion and extend the lifespan of the unit. In addition, it utilizes an advanced electronic control system that optimally monitors and adjusts the heating process, ensuring that hot water is both readily available and efficiently produced.

Another remarkable feature of the Eco Defender is its innovative venting system. The unit supports various venting configurations, including conventional and power vent, providing flexibility for installation in different home environments. This capability not only simplifies the installation process but also enhances the overall efficiency of the unit under varying conditions.

Safety is also a top priority for Bradford-White, and the U130T*FRN encapsulates numerous safety features, including a temperature and pressure relief valve and a factory-installed high-temperature limit switch. These features are critical in preventing overheating and ensuring reliable operation over time.

In terms of capacity, the U130T*FRN is available in several sizes to meet differing household demands. Whether for a small apartment or a larger family home, this model can provide sufficient hot water to meet consumption needs without sacrificing efficiency or performance.

In summary, the Bradford-White Corp U130T*FRN Eco Defender represents a well-rounded solution for residential water heating, boasting innovative technologies, durable construction, and a focus on energy efficiency and safety. This model not only meets the demands of modern households but does so in a way that promotes sustainable living. With Bradford-White's reputation for reliability, homeowners can trust the Eco Defender to deliver comfort and peace of mind.