Bradford-White Corp Eco Defender, U130T*FRN Closed Circuit Thermopile Testing Honeywell Control

Page 10

SERVICE PROCEDURE ED-II

Thermopile Testing and Replacement

CLOSED CIRCUIT THERMOPILE TESTING (Honeywell Control)

Step 1. Closed circuit testing is the preferred method for testing thermopile. Following the lighting instruction label on the heater, proceed to light the pilot and allow to operate for three minutes. If the pilot will not stay lit, hold the pilot button (rotate the gas control knob to the pilot position, push and hold in) during this test

Step 2. Using a multimeter capable of measuring millivolts, place one lead of the multi meter on the left side of the wire harness and place the second lead of the multi meter on the right side of the wire harness.

Step 3. If meter reads 300 millivolts or higher, the thermopile is OK. If reading is below 300 millivolts, replace the thermopile. For maximum thermopile life the thermopile should be replaced with a genuine Honeywell thermopile (BWC P/N 233-47063-00).

Left Side of Wire Harness

Right Side of Wire Harness

 

OPEN CIRCUIT THERMOPILE TESTING

Step 1. Disconnect red thermopile wire from wire harness leading to the gas valve. Disconnect the white thermopile wire from the resettable thermal switch

Step 2. Using a multimeter capable of measuring millivolts, connect one lead to the red thermopile wire and one lead to the white thermopile wire.

Step 3. Following the lighting instruction label on the heater, proceed to light the pilot and allow to operate for three minutes. It will be necessary to hold gas control knob down in the “PILOT” position continuously throughout this test. Any reading over 400 millivolts indicates good thermopile output.

Page 10

10

Image 10
Contents Bradford White Bradford White Introduction How to Use This Manual Probable Cause Service Procedure LED StatusDamage to Thermowell wire Inner Door Removal Procedure Inner Door Gasket Replacement Procedure Place. do not Over Tighten ScrewsPosition Thermopile Wire Pilot Tube and Igniter Wire Closed Circuit Thermopile Testing Honeywell Control Open Circuit Thermopile TestingThermopile Replacement PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement IGNITER, Electrode Testing and Replacement Thermal Well Testing Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Assembly to Thermal Well Chamber Sensor Testing Temperature Range oF Resistance Range kOhmsMain Burner Inspection Cleaning and Replacement Burner CleaningBurner Cleaning Resettable Thermal Switch Continuity Testing Resettable Thermal Switch Replacement Do not Over Tighten ScrewsScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

U130T*FRN, Eco Defender specifications

Bradford-White Corp is a leading name in the water heating industry, known for its commitment to quality and innovation. One of its standout products is the U130T*FRN Eco Defender, a water heater that combines advanced technologies with user-focused design.

The U130T*FRN Eco Defender is a high-efficiency residential water heater that offers various features aimed at maximizing both performance and energy savings. One of its key characteristics is its environmentally friendly operation. This model meets stringent energy efficiency standards, making it an excellent choice for eco-conscious homeowners looking to minimize their carbon footprint. The Eco Defender serves not only to heat water but also to deliver an energy-efficient solution that can contribute to lowering utility bills.

Equipped with a durable design, the U130T*FRN features a robust tank constructed from high-grade steel, complemented by a glass lining that helps prevent corrosion and extend the lifespan of the unit. In addition, it utilizes an advanced electronic control system that optimally monitors and adjusts the heating process, ensuring that hot water is both readily available and efficiently produced.

Another remarkable feature of the Eco Defender is its innovative venting system. The unit supports various venting configurations, including conventional and power vent, providing flexibility for installation in different home environments. This capability not only simplifies the installation process but also enhances the overall efficiency of the unit under varying conditions.

Safety is also a top priority for Bradford-White, and the U130T*FRN encapsulates numerous safety features, including a temperature and pressure relief valve and a factory-installed high-temperature limit switch. These features are critical in preventing overheating and ensuring reliable operation over time.

In terms of capacity, the U130T*FRN is available in several sizes to meet differing household demands. Whether for a small apartment or a larger family home, this model can provide sufficient hot water to meet consumption needs without sacrificing efficiency or performance.

In summary, the Bradford-White Corp U130T*FRN Eco Defender represents a well-rounded solution for residential water heating, boasting innovative technologies, durable construction, and a focus on energy efficiency and safety. This model not only meets the demands of modern households but does so in a way that promotes sustainable living. With Bradford-White's reputation for reliability, homeowners can trust the Eco Defender to deliver comfort and peace of mind.