Bradford-White Corp Eco Defender, U130T*FRN warranty Chamber Sensor Testing

Page 18

SERVICE PROCEDURE ED-V

Gas Control Replacement Thermal

Well and Chamber Door Sensor

Testing and Replacement

CHAMBER SENSOR TESTING

Step 1. Turn the gas control knob to the “OFF” position

Step 2. Disconnect the chamber sensor wire harness from the gas valve.

Step 3. Remove the chamber door temperature sensor from the right side inner door (Phillips screw driver).

Step 4. Make sure that the ring terminal of the chamber door temperature sensor is not touching any surface. Using a multi-meter set to the ohms setting, insert one meter probe (see caution) into each of the wire positions (see photo 5).

Step 5. Measure the ambient air temperature near the sensor. Compare the ambient temperature range to the expected resistance range on the chart below. Note that resistance increases as temperature decreases.

Gas Control Knob Shown In

“OFF” Position

Chamber Door

Temperature Sensor

Wire Harness

5

CAUTION

DO NOT use standard multimeter probes for this test. Doing so will damage connector. Use special pin type electronic probes or small diameter wire pins inserted into connector.

Sensor Resistance at Various Temperatures

Temperature Range (oF) Resistance Range (kOhms)

41-50

279-175

50-59

219-139

59-68

173-112

68-77

137-90

77-86

110-72

86-104

89-59

104-113

73-48

113-122

60-39

122-131

49-32

Step 6. Replace the chamber door temperature sensor if it it out of specification.

Step 7. Secure the chamber door temperature sensor to the right side inner door using the screw from step 3. Step 8. Connect the chamber door temperature sensor wire harness to the gas valve.

Step 9. To resume operation, follow the instruction located on the lighting instruction label or the lighting instruction located in the installation and operation manual.

Page 18

18

Image 18
Contents Bradford White Bradford White Introduction How to Use This Manual Probable Cause Service Procedure LED StatusDamage to Thermowell wire Inner Door Removal Procedure Inner Door Gasket Replacement Procedure Place. do not Over Tighten ScrewsPosition Thermopile Wire Pilot Tube and Igniter Wire Closed Circuit Thermopile Testing Honeywell Control Open Circuit Thermopile TestingThermopile Replacement PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement IGNITER, Electrode Testing and Replacement Thermal Well Testing Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Assembly to Thermal Well Chamber Sensor Testing Temperature Range oF Resistance Range kOhmsMain Burner Inspection Cleaning and Replacement Burner CleaningBurner Cleaning Resettable Thermal Switch Continuity Testing Resettable Thermal Switch Replacement Do not Over Tighten ScrewsScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

U130T*FRN, Eco Defender specifications

Bradford-White Corp is a leading name in the water heating industry, known for its commitment to quality and innovation. One of its standout products is the U130T*FRN Eco Defender, a water heater that combines advanced technologies with user-focused design.

The U130T*FRN Eco Defender is a high-efficiency residential water heater that offers various features aimed at maximizing both performance and energy savings. One of its key characteristics is its environmentally friendly operation. This model meets stringent energy efficiency standards, making it an excellent choice for eco-conscious homeowners looking to minimize their carbon footprint. The Eco Defender serves not only to heat water but also to deliver an energy-efficient solution that can contribute to lowering utility bills.

Equipped with a durable design, the U130T*FRN features a robust tank constructed from high-grade steel, complemented by a glass lining that helps prevent corrosion and extend the lifespan of the unit. In addition, it utilizes an advanced electronic control system that optimally monitors and adjusts the heating process, ensuring that hot water is both readily available and efficiently produced.

Another remarkable feature of the Eco Defender is its innovative venting system. The unit supports various venting configurations, including conventional and power vent, providing flexibility for installation in different home environments. This capability not only simplifies the installation process but also enhances the overall efficiency of the unit under varying conditions.

Safety is also a top priority for Bradford-White, and the U130T*FRN encapsulates numerous safety features, including a temperature and pressure relief valve and a factory-installed high-temperature limit switch. These features are critical in preventing overheating and ensuring reliable operation over time.

In terms of capacity, the U130T*FRN is available in several sizes to meet differing household demands. Whether for a small apartment or a larger family home, this model can provide sufficient hot water to meet consumption needs without sacrificing efficiency or performance.

In summary, the Bradford-White Corp U130T*FRN Eco Defender represents a well-rounded solution for residential water heating, boasting innovative technologies, durable construction, and a focus on energy efficiency and safety. This model not only meets the demands of modern households but does so in a way that promotes sustainable living. With Bradford-White's reputation for reliability, homeowners can trust the Eco Defender to deliver comfort and peace of mind.