Bradford-White Corp U130T*FRN, Eco Defender Position Thermopile Wire Pilot Tube and Igniter Wire

Page 9

SERVICE PROCEDURE ED-I

Burner and Inner Door/Gasket Removal,

Inspection, Replacement and

Reinstallation

Position Thermopile Wire,

Pilot Tube and Igniter Wire

Step 10. Firmly place right side inner door flange against the burner door flange and secure with two ¼” drive screws from step 3e. DO NOT OVER TIGHTEN SCREWS.

Step 11. Align right side inner door to combustion chamber and verify the fastener holes of the combustion chamber are aligned with the right side inner door slotted opening. Verify seal integrity around combustion opening. Secure right side inner door using 1/4” hex drive screws from step 3b. DO NOT OVER TIGHTEN SCREWS. Verify both burner and right sides of the inner door are properly positioned and sealed against the combustion chamber.

Step 12. Reconnect lead wires from gas valve to resettable thermal switch (See photo in step 3). Note, the white wire needs to be connected to the thermal switch and the red wire needs to be connected to the red wire from the thermopile.

Step 13. Reconnect the wire harness from the chamber door temperature sensor to the gas valve (See photo in step 3). Step 14. Tighten the pilot nut to the gas valve.

Step 15. Replace outer jacket burner access door.

Step 16. To resume operation follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

Page 9

9

Image 9
Contents Bradford White Bradford White Introduction How to Use This Manual LED Status Probable Cause Service ProcedureDamage to Thermowell wire Inner Door Removal Procedure Place. do not Over Tighten Screws Inner Door Gasket Replacement ProcedurePosition Thermopile Wire Pilot Tube and Igniter Wire Open Circuit Thermopile Testing Closed Circuit Thermopile Testing Honeywell ControlThermopile Replacement PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement IGNITER, Electrode Testing and Replacement Thermal Well Testing Sensor Resistance at Various Temperatures Determine Water Temperature Inside TankGas Control & Thermal Well Removal From Water Heater Gas Control Assembly to Thermal Well Temperature Range oF Resistance Range kOhms Chamber Sensor TestingBurner Cleaning Main Burner Inspection Cleaning and ReplacementBurner Cleaning Resettable Thermal Switch Continuity Testing Do not Over Tighten Screws Resettable Thermal Switch ReplacementScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

U130T*FRN, Eco Defender specifications

Bradford-White Corp is a leading name in the water heating industry, known for its commitment to quality and innovation. One of its standout products is the U130T*FRN Eco Defender, a water heater that combines advanced technologies with user-focused design.

The U130T*FRN Eco Defender is a high-efficiency residential water heater that offers various features aimed at maximizing both performance and energy savings. One of its key characteristics is its environmentally friendly operation. This model meets stringent energy efficiency standards, making it an excellent choice for eco-conscious homeowners looking to minimize their carbon footprint. The Eco Defender serves not only to heat water but also to deliver an energy-efficient solution that can contribute to lowering utility bills.

Equipped with a durable design, the U130T*FRN features a robust tank constructed from high-grade steel, complemented by a glass lining that helps prevent corrosion and extend the lifespan of the unit. In addition, it utilizes an advanced electronic control system that optimally monitors and adjusts the heating process, ensuring that hot water is both readily available and efficiently produced.

Another remarkable feature of the Eco Defender is its innovative venting system. The unit supports various venting configurations, including conventional and power vent, providing flexibility for installation in different home environments. This capability not only simplifies the installation process but also enhances the overall efficiency of the unit under varying conditions.

Safety is also a top priority for Bradford-White, and the U130T*FRN encapsulates numerous safety features, including a temperature and pressure relief valve and a factory-installed high-temperature limit switch. These features are critical in preventing overheating and ensuring reliable operation over time.

In terms of capacity, the U130T*FRN is available in several sizes to meet differing household demands. Whether for a small apartment or a larger family home, this model can provide sufficient hot water to meet consumption needs without sacrificing efficiency or performance.

In summary, the Bradford-White Corp U130T*FRN Eco Defender represents a well-rounded solution for residential water heating, boasting innovative technologies, durable construction, and a focus on energy efficiency and safety. This model not only meets the demands of modern households but does so in a way that promotes sustainable living. With Bradford-White's reputation for reliability, homeowners can trust the Eco Defender to deliver comfort and peace of mind.