Bradford-White Corp Eco Defender, U130T*FRN warranty DIP Tube Inspection and Replacement

Page 24

SERVICE PROCEDURE ED-IX

Dip Tube and Anode

Inspection and Replacement

DIP TUBE INSPECTION AND REPLACEMENT

WARNING

Water Heater components and stored water may be HOT when performing the following

steps in this procedure. Take necessary precaution to prevent personal injury.

Step 1. Rotate gas control knob to the “OFF” position.

Gas Control Knob Shown In

“OFF” Position

Step 2. Turn off cold water supply to water heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining. Open drain spigot of water heater and allow water heater to drain to a point below the inlet connection nipple.

Step 3. Disconnect inlet nipple from plumbing system.

Step 4 With an appropriate wrench, remove inlet nipple/dip tube from the water heater. Use caution not to damage pipe threads.

Step 5. Visually Inspect inlet nipple/dip tube. Inlet nipple/dip tube should be free of cracks and any blockage. Hydro-jets located near the bottom of the dip tube should be open and free of any blockage. Anti-siphon hole located approximately 6" from the bottom of nipple, should be free of any blockage.

Any damage such as cracks, restriction due to deformation or unintentional holes are not field repairable and the inlet nipple/dip tube must be replaced.

Step 6. Upon completion of inspection or subsequent replacement, reinstall inlet nipple/dip tube into heater. Connect nipple to plumbing system, resume water supply and refill water heater with water.

Step 7. To resume operation follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

Page 24

24

Image 24
Contents Bradford White Bradford White Introduction How to Use This Manual Probable Cause Service Procedure LED StatusDamage to Thermowell wire Inner Door Removal Procedure Inner Door Gasket Replacement Procedure Place. do not Over Tighten ScrewsPosition Thermopile Wire Pilot Tube and Igniter Wire Closed Circuit Thermopile Testing Honeywell Control Open Circuit Thermopile TestingThermopile Replacement PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement IGNITER, Electrode Testing and Replacement Thermal Well Testing Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Assembly to Thermal Well Chamber Sensor Testing Temperature Range oF Resistance Range kOhmsMain Burner Inspection Cleaning and Replacement Burner CleaningBurner Cleaning Resettable Thermal Switch Continuity Testing Resettable Thermal Switch Replacement Do not Over Tighten ScrewsScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

U130T*FRN, Eco Defender specifications

Bradford-White Corp is a leading name in the water heating industry, known for its commitment to quality and innovation. One of its standout products is the U130T*FRN Eco Defender, a water heater that combines advanced technologies with user-focused design.

The U130T*FRN Eco Defender is a high-efficiency residential water heater that offers various features aimed at maximizing both performance and energy savings. One of its key characteristics is its environmentally friendly operation. This model meets stringent energy efficiency standards, making it an excellent choice for eco-conscious homeowners looking to minimize their carbon footprint. The Eco Defender serves not only to heat water but also to deliver an energy-efficient solution that can contribute to lowering utility bills.

Equipped with a durable design, the U130T*FRN features a robust tank constructed from high-grade steel, complemented by a glass lining that helps prevent corrosion and extend the lifespan of the unit. In addition, it utilizes an advanced electronic control system that optimally monitors and adjusts the heating process, ensuring that hot water is both readily available and efficiently produced.

Another remarkable feature of the Eco Defender is its innovative venting system. The unit supports various venting configurations, including conventional and power vent, providing flexibility for installation in different home environments. This capability not only simplifies the installation process but also enhances the overall efficiency of the unit under varying conditions.

Safety is also a top priority for Bradford-White, and the U130T*FRN encapsulates numerous safety features, including a temperature and pressure relief valve and a factory-installed high-temperature limit switch. These features are critical in preventing overheating and ensuring reliable operation over time.

In terms of capacity, the U130T*FRN is available in several sizes to meet differing household demands. Whether for a small apartment or a larger family home, this model can provide sufficient hot water to meet consumption needs without sacrificing efficiency or performance.

In summary, the Bradford-White Corp U130T*FRN Eco Defender represents a well-rounded solution for residential water heating, boasting innovative technologies, durable construction, and a focus on energy efficiency and safety. This model not only meets the demands of modern households but does so in a way that promotes sustainable living. With Bradford-White's reputation for reliability, homeowners can trust the Eco Defender to deliver comfort and peace of mind.