SERVICE PROCEDURE ED-VII

Resettable Thermal Switch

Testing and Replacement

RESETTABLE THERMAL SWITCH REPLACEMENT

Step 1. Rotate gas control knob to the “OFF” position.

Gas Control Knob Shown In

“OFF” Position

Step 2. Remove outer jacket door.

Step 3. Disconnect wire leads from resettable thermal switch.

Step 4. Remove (2) ¼” hex drive screws from the manifold mount.

Step 5. Bend the flexible feed line so the resettable thermal switch is easily accessible.

Step 6. Remove resettable thermal switch from manifold mount (Phillips screw driver).

Manifold Mount

Step 7. Place new resettable thermal switch in place. Be sure contact surface of resettable thermal switch and manifold mount are free of any debris. Secure resettable thermal switch into place using screws from step 6.

DO NOT OVER TIGHTEN SCREWS.

Step 8. Bend flexible feed line back in place and secure the manifold mount using the screws from step 4. Step 9. Reconnect wire leads from gas valve and thermopile to resettable thermal switch.

Note: Wire termination are interchangeable with either resettable thermal switch connection. Step 10. Replace outer jacket door.

Step 11. To resume operation follow the instructions located on the lighting instruction label or the lighting instruction located in the installation and operation manual.

Page 22

22

Image 22
Contents Bradford White Bradford White Introduction How to Use This Manual Probable Cause Service Procedure LED StatusDamage to Thermowell wire Inner Door Removal Procedure Inner Door Gasket Replacement Procedure Place. do not Over Tighten ScrewsPosition Thermopile Wire Pilot Tube and Igniter Wire Closed Circuit Thermopile Testing Honeywell Control Open Circuit Thermopile TestingThermopile Replacement PILOT/ELECTRODE Assembly Inspection Cleaning and Replacement IGNITER, Electrode Testing and Replacement Thermal Well Testing Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Assembly to Thermal Well Chamber Sensor Testing Temperature Range oF Resistance Range kOhmsMain Burner Inspection Cleaning and Replacement Burner CleaningBurner Cleaning Resettable Thermal Switch Continuity Testing Resettable Thermal Switch Replacement Do not Over Tighten ScrewsScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

U130T*FRN, Eco Defender specifications

Bradford-White Corp is a leading name in the water heating industry, known for its commitment to quality and innovation. One of its standout products is the U130T*FRN Eco Defender, a water heater that combines advanced technologies with user-focused design.

The U130T*FRN Eco Defender is a high-efficiency residential water heater that offers various features aimed at maximizing both performance and energy savings. One of its key characteristics is its environmentally friendly operation. This model meets stringent energy efficiency standards, making it an excellent choice for eco-conscious homeowners looking to minimize their carbon footprint. The Eco Defender serves not only to heat water but also to deliver an energy-efficient solution that can contribute to lowering utility bills.

Equipped with a durable design, the U130T*FRN features a robust tank constructed from high-grade steel, complemented by a glass lining that helps prevent corrosion and extend the lifespan of the unit. In addition, it utilizes an advanced electronic control system that optimally monitors and adjusts the heating process, ensuring that hot water is both readily available and efficiently produced.

Another remarkable feature of the Eco Defender is its innovative venting system. The unit supports various venting configurations, including conventional and power vent, providing flexibility for installation in different home environments. This capability not only simplifies the installation process but also enhances the overall efficiency of the unit under varying conditions.

Safety is also a top priority for Bradford-White, and the U130T*FRN encapsulates numerous safety features, including a temperature and pressure relief valve and a factory-installed high-temperature limit switch. These features are critical in preventing overheating and ensuring reliable operation over time.

In terms of capacity, the U130T*FRN is available in several sizes to meet differing household demands. Whether for a small apartment or a larger family home, this model can provide sufficient hot water to meet consumption needs without sacrificing efficiency or performance.

In summary, the Bradford-White Corp U130T*FRN Eco Defender represents a well-rounded solution for residential water heating, boasting innovative technologies, durable construction, and a focus on energy efficiency and safety. This model not only meets the demands of modern households but does so in a way that promotes sustainable living. With Bradford-White's reputation for reliability, homeowners can trust the Eco Defender to deliver comfort and peace of mind.