Bradford-White Corp IGI-180R, IGI-180C Remove Carton, Mount Water Heater on the Wall

Page 12

Connectors of this water heater. However, it is recommended that at least 12” (30.5 cm) from the top and 24” (61 cm) from the front be provided for servicing.

4.If the water heater is installed in a confined space, such as a closet, ventilation air must be provided to prevent increased room temperature. Excessive ambient temperatures surrounding the water heater may shorten the life of the controls.

REMOVE CARTON

Move water heater to a location near where it will be installed. Carefully slide water heater out from the carton and remove all the contents.

MOUNT WATER HEATER ON THE WALL

Determine the proper height and location for the water heater to be installed. Consider the venting system as well as the water and gas connections. Allow enough room for servicing the water heater and maintain the clearances from combustible materials previously stated. The water heater is supported on the wall by means of a top and bottom slotted angle bracket. For convenience, the center hole of the bracket is slotted so that a center screw may be first installed in the wall for hanging the water heater on the wall. Two more screws are then added on the ends of the bracket to secure the water heater. Wall anchors should be used for the bracket holes unless the bracket lines up with a stud. As an alternative, a suitable piece of plywood may be cut to span the wall studs and the brackets fastened to the plywood. Make sure the anchors are rated to support the 50 pound (23 kg) weight of the water heater.

12

Image 12
Contents IGI-180R and IGI-180C Model Series Section I Important Information Read CarefullyPage Page Table of Contents Section II Specifications Max. Flow Rate @ Degree Temperature RiseMin IGI-180C-5X First Hour 462 306 228 186 156 132 SupplyEVERHOT→ IGI Model Series Dimensions Cm, Front Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality DescriptionPage Recommended Piping for a Basic Installation Fig Recommended Piping for a Circulation System Fig Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigPage Pressure Relief Valve Section VI Venting VENT/AIR Intake Terminal Locations Direct Vent Terminal LocationExceptions for Installations Venting System Layout Venting System Installation Horizontal Direct Vent InstallationsHorizontal Direct Vent using standard vent kit components Page Vertical Vent Installations Dip Switch Settings Fig Never USE a Match or Open Flame for Testing Section VII GAS ConnectionsInitial Operation and Testing Installer only GAS Meter Size -NATURAL GAS onlyGAS Pressure Regulation Page Section Viii Electrical Connections Wiring Diagram Wiring Diagram Schematic Temperature Controls Residential ModelsPage Commercial Models Main Control for Commercial Models FigRemote Main Control Installation Optional Remote Control Wiring Connections Inside Water Heater Fig Initial Operation and Testing of Controls Installer onlySection IX Operating Instructions Sequence of OperationLighting Instructions For Your Safety Read Before Operating To Turn OFF GAS to the ApplianceManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Temperature Adjustment Main or Bath Control for Residential Models Fig Commercial Models See figureMain Control for Commercial Models Fig Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingError Messages on Remote Temperature Control Display First AID for ScaldsSection X Maintenance Burner Flame Appearance Fig Lime Scale Flushing Diagram Fig Page Schematic Diagram of Internal Parts Section XI Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Venting Components Number Description Quantity Number Description Quantity Description Quantity