Bradford-White Corp IGI-180R, IGI-180C instruction manual

Page 36

Before installing the Bath Controls, determine the most convenient locations(s). When deciding on the best location for the remote controls, please consider the following items:

1.Place the controls out of reach of small children.

2.Avoid locations where the control(s) will become hot, such as over a radiator, register, or other heat sources.

3.Avoid direct sunlight. (The digital readout can be difficult to read in direct sunlight).

4.Avoid areas where the remote can be splashed with cooking water, oil, or sauce.

5.The remote control operates with low voltage, 12 volts DC.

Main or Bath Control for Residential Models (Fig. 9)

Temperature Control(s) Installation (Optional):

1.The Bath Control (239-44507-00) and Secondary Bath Control (239-44508-00) are intended to be installed in a bathroom close to a shower or tub. The controls may be wired in series or parallel depending on the distance from the water heater to the controls.

2.Mark the holes on the wall using the control mounting plate and drill two mounting holes using a 3/32” (2.4 mm) drill bit and a clearance hole for the cable using a ¼” (6.4 mm) drill bit.

3.Run the cable from the control to the water heater or another control, which ever is closer or more convenient.

4.Remove the face plate from the remote control by inserting a screwdriver in the slot and twisting open.

5.Connect the cable to the terminal screws of the remote control.

6.Mount the control to the wall using the holes drilled and with the screws supplied. Note: Plastic wall anchors may be required if the control is not located over a stud when mounting on wallboard.

36

Image 36
Contents IGI-180R and IGI-180C Model Series Section I Important Information Read CarefullyPage Page Table of Contents Section II Specifications Max. Flow Rate @ Degree Temperature RiseMin IGI-180C-5X First Hour 462 306 228 186 156 132 SupplyEVERHOT→ IGI Model Series Dimensions Cm, Front Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality DescriptionPage Recommended Piping for a Basic Installation Fig Recommended Piping for a Circulation System Fig Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigPage Pressure Relief Valve Section VI Venting VENT/AIR Intake Terminal Locations Direct Vent Terminal LocationExceptions for Installations Venting System Layout Venting System Installation Horizontal Direct Vent InstallationsHorizontal Direct Vent using standard vent kit components Page Vertical Vent Installations Dip Switch Settings Fig Never USE a Match or Open Flame for Testing Section VII GAS ConnectionsInitial Operation and Testing Installer only GAS Meter Size -NATURAL GAS onlyGAS Pressure Regulation Page Section Viii Electrical Connections Wiring Diagram Wiring Diagram Schematic Temperature Controls Residential ModelsPage Commercial Models Main Control for Commercial Models FigRemote Main Control Installation Optional Remote Control Wiring Connections Inside Water Heater Fig Initial Operation and Testing of Controls Installer onlySection IX Operating Instructions Sequence of OperationLighting Instructions For Your Safety Read Before Operating To Turn OFF GAS to the ApplianceManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Temperature Adjustment Main or Bath Control for Residential Models Fig Commercial Models See figureMain Control for Commercial Models Fig Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingError Messages on Remote Temperature Control Display First AID for ScaldsSection X Maintenance Burner Flame Appearance Fig Lime Scale Flushing Diagram Fig Page Schematic Diagram of Internal Parts Section XI Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Venting Components Number Description Quantity Number Description Quantity Description Quantity

IGI-180C, IGI-180R specifications

Bradford-White Corporation is a well-known name in the water heating industry, offering a range of reliable and efficient products. Among its noteworthy offerings are the IGI-180R and IGI-180C indirect water heaters. These models exemplify the company's commitment to quality and innovation, featuring robust designs and cutting-edge technologies.

The IGI-180R and IGI-180C units are designed to provide a consistent supply of hot water for residential and commercial applications. Both models have a storage capacity of 180 gallons, making them ideal for settings that require large volumes of hot water, such as restaurants, schools, and larger households. Their large tanks ensure minimal wait times and a reliable hot water supply, even during peak usage periods.

One of the key features of the IGI series is their indirect heating capability. Instead of relying on electric elements or gas burners, these heaters use a separate boiler or heating system to provide the necessary heat. This allows for more efficient operation, as the water is heated more evenly and effectively. The models integrate seamlessly with existing boiler systems, making them an excellent choice for those looking to upgrade or expand their hot water capabilities without extensive modifications.

Both the IGI-180R and IGI-180C incorporate advanced insulation technology, minimizing heat loss and improving energy efficiency. The high-density foam insulation encases the tank, keeping the water hot for longer periods and reducing energy costs associated with reheating. This insulation also contributes to a longer lifespan for the unit, as it reduces the wear and tear on the heating systems.

Another pivotal characteristic of these units is their durable construction. Bradford-White utilizes high-quality materials and rigorous manufacturing standards, ensuring that the IGI models withstand the test of time. The tanks are constructed from heavy-duty steel with a glass lining that protects against corrosion and sediment buildup, enhancing the longevity and performance of the water heater.

Lastly, both models come equipped with a range of safety features, including an integrated Pressure Relief Valve and a temperature control system. These elements safeguard against overheating and pressure issues, ensuring safe operation.

In conclusion, the IGI-180R and IGI-180C indirect water heaters by Bradford-White Corporation stand out for their efficient, reliable, and durable design. With advanced heating technology, excellent insulation, and robust safety features, they are a smart investment for any hot water demand scenario.