WARNING

DO NOT tamper with or alter the water heater and/or controls.

DO NOT operate water heater with jumpered or absent controls or safety devices.

DO NOT operate water heater if any external part has been under water. Immediately call a qualified service agency to inspect the appliance and to replace any part of the control system including gas controls, which has been under water.

DO NOT attempt to use this water heater with any gas other than the type listed on the rating plate. Do not attempt to convert this water heater for use with a gas other than the type for which it is equipped. Failure to use the proper gas can create an unsafe condition resulting in property damage, bodily injury, or death. Consult your local gas supplier or gas company if there are any questions.

DO NOT operate this water heater if the input rate exceeds the rate shown on the water heater rating plate.

This water heater contains very hot water under high pressure. Do not unscrew any pipe fittings nor attempt to disconnect any components of this water heater without positively assuring the water is cool and is not under pressure. Always wear protective clothing and equipment when installing, starting up or servicing this water heater to prevent scald injuries. Do not rely on the temperature gauges to determine the temperature. Do not touch any components unless they are cool.

This water heater must be properly vented and connected to an approved vent system in good condition. DO NOT operate water heater with the absence of an approved vent system. A clean and unobstructed vent system is necessary to allow noxious fumes that could cause injury or loss of life to vent safely and will contribute toward maintaining the water heater’s efficiency.

This water heater is for indoor installation only. The supplied venting system must be used to supply outdoor air for combustion to the appliance.

This water heater requires its own separate venting system. DO NOT connect the exhaust vent into an existing vent pipe or chimney.

Water heater materials of construction, products of combustion and the fuel contain carbon monoxide, nitrogen oxides, aldehydes and/or other toxic or harmful substances which can cause death or serious injury and which are known to the state of California to cause cancer, birth defects and other reproductive harm. Always use proper safety clothing, respirators and equipment when servicing or working nearby this water heater.

4

Image 4
Contents IGI-180R and IGI-180C Model Series Section I Important Information Read CarefullyPage Page Table of Contents Section II Specifications Max. Flow Rate @ Degree Temperature RiseMin IGI-180C-5X First Hour 462 306 228 186 156 132 SupplyEVERHOT→ IGI Model Series Dimensions Cm, Front Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality DescriptionPage Recommended Piping for a Basic Installation Fig Recommended Piping for a Circulation System Fig Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigPage Pressure Relief Valve Section VI Venting VENT/AIR Intake Terminal Locations Direct Vent Terminal LocationExceptions for Installations Venting System Layout Venting System Installation Horizontal Direct Vent InstallationsHorizontal Direct Vent using standard vent kit components Page Vertical Vent Installations Dip Switch Settings Fig Never USE a Match or Open Flame for Testing Section VII GAS ConnectionsGAS Meter Size -NATURAL GAS only Initial Operation and Testing Installer onlyGAS Pressure Regulation Page Section Viii Electrical Connections Wiring Diagram Wiring Diagram Schematic Temperature Controls Residential ModelsPage Commercial Models Main Control for Commercial Models FigRemote Main Control Installation Optional Remote Control Wiring Connections Inside Water Heater Fig Initial Operation and Testing of Controls Installer onlySection IX Operating Instructions Sequence of OperationTo Turn OFF GAS to the Appliance Lighting Instructions For Your Safety Read Before OperatingManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Temperature Adjustment Main or Bath Control for Residential Models Fig Commercial Models See figureMain Control for Commercial Models Fig Approximate TIME/TEMPERATURE Relationships in Scalds ScaldingError Messages on Remote Temperature Control Display First AID for ScaldsSection X Maintenance Burner Flame Appearance Fig Lime Scale Flushing Diagram Fig Page Schematic Diagram of Internal Parts Section XI Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Venting Components Number Description Quantity Number Description Quantity Description Quantity

IGI-180C, IGI-180R specifications

Bradford-White Corporation is a well-known name in the water heating industry, offering a range of reliable and efficient products. Among its noteworthy offerings are the IGI-180R and IGI-180C indirect water heaters. These models exemplify the company's commitment to quality and innovation, featuring robust designs and cutting-edge technologies.

The IGI-180R and IGI-180C units are designed to provide a consistent supply of hot water for residential and commercial applications. Both models have a storage capacity of 180 gallons, making them ideal for settings that require large volumes of hot water, such as restaurants, schools, and larger households. Their large tanks ensure minimal wait times and a reliable hot water supply, even during peak usage periods.

One of the key features of the IGI series is their indirect heating capability. Instead of relying on electric elements or gas burners, these heaters use a separate boiler or heating system to provide the necessary heat. This allows for more efficient operation, as the water is heated more evenly and effectively. The models integrate seamlessly with existing boiler systems, making them an excellent choice for those looking to upgrade or expand their hot water capabilities without extensive modifications.

Both the IGI-180R and IGI-180C incorporate advanced insulation technology, minimizing heat loss and improving energy efficiency. The high-density foam insulation encases the tank, keeping the water hot for longer periods and reducing energy costs associated with reheating. This insulation also contributes to a longer lifespan for the unit, as it reduces the wear and tear on the heating systems.

Another pivotal characteristic of these units is their durable construction. Bradford-White utilizes high-quality materials and rigorous manufacturing standards, ensuring that the IGI models withstand the test of time. The tanks are constructed from heavy-duty steel with a glass lining that protects against corrosion and sediment buildup, enhancing the longevity and performance of the water heater.

Lastly, both models come equipped with a range of safety features, including an integrated Pressure Relief Valve and a temperature control system. These elements safeguard against overheating and pressure issues, ensuring safe operation.

In conclusion, the IGI-180R and IGI-180C indirect water heaters by Bradford-White Corporation stand out for their efficient, reliable, and durable design. With advanced heating technology, excellent insulation, and robust safety features, they are a smart investment for any hot water demand scenario.