6.Pressing the “Maintenance Button” followed by the “H” button will display a sequence of error codes, if any, stored in memory that has been experienced. Any current error codes will be displayed on the digital monitor in sequence starting with the most recent code.

7.To display the water flow through the water heater with hot water in use, depress the “H” button for 2 seconds and then simultaneously press the “M” button. (GPM = Display Readout X 0.1).

8.To display the outlet water temperature while in use, depress the “C” button for 2 seconds and then simultaneously press the “M” button.

CAUTION

Check local codes for the maximum water temperature setting allowed when used in nursing homes, schools, day care centers, and all other public use applications.

Main Control for Commercial Models (Fig. 10)

45

Image 45
Contents IGI-180R and IGI-180C Model Series Read Carefully Section I Important InformationPage Page Table of Contents Max. Flow Rate @ Degree Temperature Rise Section II SpecificationsMin IGI-180C-5X First Hour 462 306 228 186 156 132 SupplyEVERHOT→ IGI Model Series Dimensions Cm, Front Section III General Information FeaturesDo not Operate the Appliance Until the Leakage is Corrected Section IV Installation InstructionsWater Heater Location UnpackingMount Water Heater on the Wall Remove CartonSection V Water Connections Lime Condition Warning SignalWater Quality DescriptionPage Recommended Piping for a Basic Installation Fig Recommended Piping for a Circulation System Fig Drain Solenoid Piping Fig Recommended Piping for Power Failure Freeze ProtectionPage Pressure Relief Valve Section VI Venting Direct Vent Terminal Location VENT/AIR Intake Terminal LocationsExceptions for Installations Venting System Layout Horizontal Direct Vent Installations Venting System InstallationHorizontal Direct Vent using standard vent kit components Page Vertical Vent Installations Dip Switch Settings Fig Section VII GAS Connections Never USE a Match or Open Flame for TestingInitial Operation and Testing Installer only GAS Meter Size -NATURAL GAS onlyGAS Pressure Regulation Page Section Viii Electrical Connections Wiring Diagram Wiring Diagram Schematic Residential Models Temperature ControlsPage Main Control for Commercial Models Fig Commercial ModelsRemote Main Control Installation Optional Initial Operation and Testing of Controls Installer only Remote Control Wiring Connections Inside Water Heater FigSequence of Operation Section IX Operating InstructionsLighting Instructions For Your Safety Read Before Operating To Turn OFF GAS to the ApplianceManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Temperature Adjustment Commercial Models See figure Main or Bath Control for Residential Models FigMain Control for Commercial Models Fig Scalding Approximate TIME/TEMPERATURE Relationships in ScaldsFirst AID for Scalds Error Messages on Remote Temperature Control DisplaySection X Maintenance Burner Flame Appearance Fig Lime Scale Flushing Diagram Fig Page Schematic Diagram of Internal Parts Section XI Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Venting Components Number Description Quantity Number Description Quantity Description Quantity

IGI-180C, IGI-180R specifications

Bradford-White Corporation is a well-known name in the water heating industry, offering a range of reliable and efficient products. Among its noteworthy offerings are the IGI-180R and IGI-180C indirect water heaters. These models exemplify the company's commitment to quality and innovation, featuring robust designs and cutting-edge technologies.

The IGI-180R and IGI-180C units are designed to provide a consistent supply of hot water for residential and commercial applications. Both models have a storage capacity of 180 gallons, making them ideal for settings that require large volumes of hot water, such as restaurants, schools, and larger households. Their large tanks ensure minimal wait times and a reliable hot water supply, even during peak usage periods.

One of the key features of the IGI series is their indirect heating capability. Instead of relying on electric elements or gas burners, these heaters use a separate boiler or heating system to provide the necessary heat. This allows for more efficient operation, as the water is heated more evenly and effectively. The models integrate seamlessly with existing boiler systems, making them an excellent choice for those looking to upgrade or expand their hot water capabilities without extensive modifications.

Both the IGI-180R and IGI-180C incorporate advanced insulation technology, minimizing heat loss and improving energy efficiency. The high-density foam insulation encases the tank, keeping the water hot for longer periods and reducing energy costs associated with reheating. This insulation also contributes to a longer lifespan for the unit, as it reduces the wear and tear on the heating systems.

Another pivotal characteristic of these units is their durable construction. Bradford-White utilizes high-quality materials and rigorous manufacturing standards, ensuring that the IGI models withstand the test of time. The tanks are constructed from heavy-duty steel with a glass lining that protects against corrosion and sediment buildup, enhancing the longevity and performance of the water heater.

Lastly, both models come equipped with a range of safety features, including an integrated Pressure Relief Valve and a temperature control system. These elements safeguard against overheating and pressure issues, ensuring safe operation.

In conclusion, the IGI-180R and IGI-180C indirect water heaters by Bradford-White Corporation stand out for their efficient, reliable, and durable design. With advanced heating technology, excellent insulation, and robust safety features, they are a smart investment for any hot water demand scenario.