Bradford-White Corp IGI-180C Lighting Instructions For Your Safety Read Before Operating

Page 41
A. This appliance does not have a pilot. It is equipped with a direct ignition device, which automatically lights the burner. Do not try to light the burner by hand.
B. BEFORE OPERATING: Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

C. Use only your hand to operate the remote control keypad. Never use tools. If the remote keypad doesn’t work, do not try to repair it, call a qualified service technician. Forced or improper repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OPERATING INSTRUCTIONS

1.

STOP! Read the safety information

6.

Wait (5) minutes to clear out any gas. If you

 

above before proceeding.

 

then smell gas, STOP! Follow “B” in the safety

 

 

 

information above on this label. If you don’t smell

 

 

 

gas, go to next step.

 

2.

Set the thermostat to the lowest

7.

Turn the manual valve located at the gas inlet of

 

setting.

 

appliance counterclockwise

to “ON” (see

 

 

 

Figure 12).

 

3.

Turn off all power to the electrical

8.

Turn on all electric power to the appliance.

 

appliance.

 

 

 

4.

This appliance does not have a pilot.

9.

Set the thermostat to desired setting.

 

It is equipped with a direct ignition

 

 

 

 

device, which automatically lights

10.

If the appliance will not operate, Follow the

 

the burner. Do not try to light the

 

instructions “To Turn Off Gas To Appliance” and

 

burner by hand.

 

call your service technician or gas supplier.

5.Turn the manual valve located at the gas inlet of the appliance clockwise to “OFF” (see Figure 12).

TO TURN OFF GAS TO THE APPLIANCE

1. Set the thermostat to the lowest

3. Turn the manual valve at gas inlet of appliance

setting.

clockwise

to “OFF” (see Figure 9).

2.Turn off all electric power to the appliance if service is to be performed.

Manual Gas Valve (Fig. 12)

41

Image 41
Contents IGI-180R and IGI-180C Model Series Read Carefully Section I Important InformationPage Page Table of Contents Max. Flow Rate @ Degree Temperature Rise Section II SpecificationsMin IGI-180C-5X First Hour 462 306 228 186 156 132 SupplyEVERHOT→ IGI Model Series Dimensions Cm, Front Section III General Information FeaturesDo not Operate the Appliance Until the Leakage is Corrected Section IV Installation InstructionsWater Heater Location UnpackingMount Water Heater on the Wall Remove CartonSection V Water Connections Lime Condition Warning SignalWater Quality DescriptionPage Recommended Piping for a Basic Installation Fig Recommended Piping for a Circulation System Fig Drain Solenoid Piping Fig Recommended Piping for Power Failure Freeze ProtectionPage Pressure Relief Valve Section VI Venting Direct Vent Terminal Location VENT/AIR Intake Terminal LocationsExceptions for Installations Venting System Layout Horizontal Direct Vent Installations Venting System InstallationHorizontal Direct Vent using standard vent kit components Page Vertical Vent Installations Dip Switch Settings Fig Section VII GAS Connections Never USE a Match or Open Flame for TestingGAS Pressure Regulation Initial Operation and Testing Installer onlyGAS Meter Size -NATURAL GAS only Page Section Viii Electrical Connections Wiring Diagram Wiring Diagram Schematic Residential Models Temperature ControlsPage Main Control for Commercial Models Fig Commercial Models Remote Main Control Installation Optional Initial Operation and Testing of Controls Installer only Remote Control Wiring Connections Inside Water Heater FigSequence of Operation Section IX Operating InstructionsManual Gas Valve Fig Lighting Instructions For Your Safety Read Before OperatingTo Turn OFF GAS to the Appliance Turning OFF the Water Heater for AN Extended Period of Time Temperature Adjustment Commercial Models See figure Main or Bath Control for Residential Models FigMain Control for Commercial Models Fig Scalding Approximate TIME/TEMPERATURE Relationships in ScaldsFirst AID for Scalds Error Messages on Remote Temperature Control DisplaySection X Maintenance Burner Flame Appearance Fig Lime Scale Flushing Diagram Fig Page Schematic Diagram of Internal Parts Section XI Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Venting Components Number Description Quantity Number Description Quantity Description Quantity