Bradford-White Corp IGI-180C, IGI-180R Main Control for Commercial Models Fig

Page 37

Note: If the cable cannot be run inside the wall cavity, then the plastic knockout should be removed from the top or bottom of the control to allow flush mounting with the wall.

7.Disconnect the power from the water heater and remove the front cover.

8.Remove the plastic cover from the PCB and electrical connections.

9.Thread the cable through the access hole at the base of the water heater and connect the wires to the control terminals on the right hand side of the PCB. Refer to the control wiring illustration at the end of this section.

10.Secure the control cable using the clamp provided in the control compartment.

11.Replace the plastic cover over the PCB terminals and then replace the front control panel of the water heater.

WARNING

Do not attempt to connect the remote controls with the power on to the water heater. There is 120 volt terminals and wiring next to the remote control connections inside the unit. All servicing and wiring must be performed by a qualified installer.

Commercial Models:

The Main Control is integrally mounted to project through the front panel and has a temperature adjustment range of 96-180°F. In addition, the control will display fault codes in the event the water heater needs service. Only one control may be used on commercial models. If a remotely located control is desired in an area where most of the hot water is used, then a Main Control for commercial models (239-44510-00) must be purchased and the integral Main Control on the water heater must be disconnected.

Main Control for Commercial Models (Fig. 10)

37

Image 37
Contents IGI-180R and IGI-180C Model Series Read Carefully Section I Important InformationPage Page Table of Contents Max. Flow Rate @ Degree Temperature Rise Section II SpecificationsMin IGI-180C-5X First Hour 462 306 228 186 156 132 SupplyEVERHOT→ IGI Model Series Dimensions Cm, Front Section III General Information FeaturesDo not Operate the Appliance Until the Leakage is Corrected Section IV Installation InstructionsWater Heater Location UnpackingMount Water Heater on the Wall Remove CartonSection V Water Connections Lime Condition Warning SignalWater Quality DescriptionPage Recommended Piping for a Basic Installation Fig Recommended Piping for a Circulation System Fig Drain Solenoid Piping Fig Recommended Piping for Power Failure Freeze ProtectionPage Pressure Relief Valve Section VI Venting Direct Vent Terminal Location VENT/AIR Intake Terminal LocationsExceptions for Installations Venting System Layout Horizontal Direct Vent Installations Venting System InstallationHorizontal Direct Vent using standard vent kit components Page Vertical Vent Installations Dip Switch Settings Fig Section VII GAS Connections Never USE a Match or Open Flame for TestingGAS Meter Size -NATURAL GAS only Initial Operation and Testing Installer onlyGAS Pressure Regulation Page Section Viii Electrical Connections Wiring Diagram Wiring Diagram Schematic Residential Models Temperature ControlsPage Main Control for Commercial Models Fig Commercial ModelsRemote Main Control Installation Optional Initial Operation and Testing of Controls Installer only Remote Control Wiring Connections Inside Water Heater FigSequence of Operation Section IX Operating InstructionsTo Turn OFF GAS to the Appliance Lighting Instructions For Your Safety Read Before OperatingManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Temperature Adjustment Commercial Models See figure Main or Bath Control for Residential Models FigMain Control for Commercial Models Fig Scalding Approximate TIME/TEMPERATURE Relationships in ScaldsFirst AID for Scalds Error Messages on Remote Temperature Control DisplaySection X Maintenance Burner Flame Appearance Fig Lime Scale Flushing Diagram Fig Page Schematic Diagram of Internal Parts Section XI Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Venting Components Number Description Quantity Number Description Quantity Description Quantity