Bradford-White Corp IGE-199R, IGE-199C Section V Water Connections, Water Quality

Page 12

SECTION V: WATER CONNECTIONS

WARNING

Failure to install and maintain a new, listed pressure relief valve will release the manufacturer from any claim, which might result from excessive temperature and pressures.

Keep clear of the pressure relief valve discharge line outlet. The discharge may be hot enough to cause scald injury. The water is under pressure and may splash.

WARNING

DO NOT reverse the inlet and outlet (cold and hot water) connections on the water heater. This may cause a hazardous operating condition or the water heater may be inoperable

WATER QUALITY

The EVERHOTwater heater must have the water quality within the following limits for long life and reliable operation (see Table 2). The water supply should be tested to make sure the quality is within the specified limits. If there is a problem with the water quality, contact your local water conditioning company for equipment to condition the water supply to this appliance.

NOTICE

Operating this water heater with water conditions outside the specified limits will void the warranty.

Table 2

 

 

TDS

Total

 

 

 

 

 

 

Description

pH

(Total

Aluminum

Chlorides

Copper

Iron

Manganese

Zinc

Dissolved

Hardness

 

 

 

 

 

 

 

 

 

 

Solids)

 

 

 

 

 

 

 

 

 

 

Up to

 

 

 

 

 

 

Levels

6.5 to

Up to 500

200 ppm

Up to 0.2

Up to

Up to

Up to

Up to 0.05

Up to

or 11.7

0.3

8.5

ppm

ppm

250 ppm

1.0 ppm

ppm

5 ppm

 

grains of

ppm

 

 

 

 

 

 

 

 

 

 

 

hardness

 

 

 

 

 

 

Lime Condition Warning Signal:

If the EVERHOT water heater is operated under hard water conditions without a water conditioner, the error code “LC” may flash on the remote temperature display. This code means the heat exchanger coil is beginning to accumulate scale deposits and MUST be flushed (see Section IX, “Flushing Procedure for Lime Scale Removal…”). Contact your installer for a qualified service technician to flush the heat exchanger. A water conditioner may be needed to prevent this condition from reoccurring.

NOTICE

Failure to flush the appliance when “LC” is flashing will cause damage to the heat exchanger. Damage caused by lime or scale build up is not covered by the water heater warranty.

INSTRUCTIONS FOR CONNECTIONS

1.BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while making the water connections to the water heater. The COLD water inlet and HOT water outlet are identified on the bottom casing of the water heater. Make the proper plumbing connections between the water heater and the plumbing system to the house. All soldering materials and piping must be compatible with potable water. Unions should be installed on both the hot and cold water lines for future servicing and disconnection of the water heater. Install a shut-off valve in the cold water supply line.

12

Image 12
Contents IGE-199R and IGE-199C Model Series Section I Important Information Read CarefullyPage Do not Operate the Appliance Until the Leakage is Corrected Table of Contents Section II Specifications IGE-199R-10XEVERHOT→ IGE Model Series Dimensions Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationBuild Opening Clearances Fig Reference Description Minimum Distance Inches cmRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality Instructions for ConnectionsPage Recommended Piping for a Basic Installation Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigRecommended Piping for a Circulation System Page Pressure Relief Valve Never USE a Match or Open Flame for Testing Section VI GAS ConnectionsInitial Operation and Testing Installer only GAS Meter Size -NATURALGAS onlyGAS Pressure Regulation Page Section VII Electrical Connections Wiring Diagram Wiring Diagram Schematic Remote Temperature Controls Residential ModelsPage Commercial Models Control Wiring Connections Inside Water Heater Initial Operation and Testing of Controls Installer onlySection Viii Operating Instructions To Fill the Water HeaterSequence of Operation Lighting Instructions For Your Safety Read Before Operating To Turn OFF GAS to the ApplianceManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Residential Models see FigureMain or Bath Control For Residential Models Fig Commercial Models see FigureMain Control for Commercial Models Fig Approximate TIME/TEMPERATURE Relationships in Scalds First AID for ScaldsError Messages on Remote Temperature Control Display Section IX Maintenance Burner Flame Appearance Fig Page Lime Scale Flushing Diagram Fig Schematic Diagram of Internal Parts Section X Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Parts List Anti-Frost Heater Clip

IGE-199R, IGE-199C specifications

Bradford-White Corp is renowned for its commitment to high-quality water heating and storage solutions, and its IGE-199C and IGE-199R models are prime examples of their innovation in the domain of gas-fired water heaters. These units are designed specifically for commercial applications, catering to restaurants, hotels, and other establishments that require efficient and reliable hot water supply systems.

One of the standout features of the IGE-199C and IGE-199R models is their energy efficiency. Both models utilize advanced technology to ensure minimized energy consumption while maximizing performance. They are equipped with a robust gas burner that delivers rapid heating capabilities, making them ideal for businesses with high demand for hot water. With an Energy Factor rating that meets or exceeds industry standards, users can expect lower operational costs, contributing to overall energy savings.

The IGE-199C is a compact, natural gas-powered unit, engineered for easy installation and integration. Its unique design features a built-in venting system that simplifies the setup process, making it suitable for retrofitting into existing systems. Meanwhile, the IGE-199R model offers similar performance with added versatility, as it can operate on either natural gas or propane, providing flexibility for various installation requirements. Both models are equipped with a powerful heat exchanger that enhances heat transfer efficiency, ensuring consistent delivery of hot water.

Safety and reliability are also central to the IGE-199C and IGE-199R designs. Each unit is fitted with multiple safety features, including high-temperature limit switches and an integrated drain valve, ensuring safe operation under all conditions. The durable construction of these water heaters, with heavy-duty commercial-grade materials, enhances longevity while reducing the likelihood of maintenance issues.

Another notable characteristic is their user-friendly control systems, enabling easy adjustments to temperature settings and monitoring of performance metrics. This ensures that operators can maintain optimal performance levels without extensive training or technical knowledge.

In summary, the Bradford-White IGE-199C and IGE-199R models are state-of-the-art gas-fired water heaters that combine efficiency, safety, and reliability. Their innovative features and technologies make them ideal for demanding commercial applications, providing businesses with an effective solution for their hot water needs. With their focus on durability and performance, these models exemplify Bradford-White's dedication to excellence in water heating technology.