Bradford-White Corp IGE-199R Lighting Instructions For Your Safety Read Before Operating

Page 30
A. This appliance does not have a pilot. It is equipped with a direct ignition device, which automatically lights the burner. Do not try to light the burner by hand.
B. BEFORE OPERATING: Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

C. Use only your hand to operate the remote control keypad. Never use tools. If the remote keypad doesn’t work, do not try to repair it, call a qualified service technician. Forced or improper repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OPERATING INSTRUCTIONS

1.

STOP! Read the safety information

6.

Wait (5) minutes to clear out any gas. If you

 

above before proceeding.

 

then smell gas, STOP! Follow “B” in the safety

 

 

 

information above on this label. If you don’t smell

 

 

 

gas, go to next step.

 

2.

Set the thermostat to the lowest

7.

Turn the manual valve located at the gas inlet of

 

setting.

 

appliance counterclockwise

to “ON” (see

 

 

 

Figure 9).

 

3.

Turn off all power to the electrical

8.

Turn on all electric power to the appliance.

 

appliance.

 

 

 

4.

This appliance does not have a pilot.

9.

Set the thermostat to desired setting.

 

It is equipped with a direct ignition

 

 

 

 

device, which automatically lights

10.

If the appliance will not operate, Follow the

 

the burner. Do not try to light the

 

instructions “To Turn Off Gas To Appliance” and

 

burner by hand.

 

call your service technician or gas supplier.

5.Turn the manual valve located at the gas inlet of the appliance clockwise to “OFF” (see Figure 9).

TO TURN OFF GAS TO THE APPLIANCE

1. Set the thermostat to the lowest

3. Turn the manual valve at gas inlet of appliance

setting.

clockwise

to “OFF” (see Figure 9).

2.Turn off all electric power to the appliance if service is to be performed.

Manual Gas Valve (Fig 9)

30

Image 30
Contents IGE-199R and IGE-199C Model Series Section I Important Information Read CarefullyPage Do not Operate the Appliance Until the Leakage is Corrected Table of Contents Section II Specifications IGE-199R-10XEVERHOT→ IGE Model Series Dimensions Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationRemove Carton Build Opening Clearances FigReference Description Minimum Distance Inches cm Mount Water Heater on the WallWater Quality Lime Condition Warning SignalSection V Water Connections Instructions for ConnectionsPage Recommended Piping for a Basic Installation Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigRecommended Piping for a Circulation System Page Pressure Relief Valve Never USE a Match or Open Flame for Testing Section VI GAS ConnectionsInitial Operation and Testing Installer only GAS Meter Size -NATURALGAS onlyGAS Pressure Regulation Page Section VII Electrical Connections Wiring Diagram Wiring Diagram Schematic Remote Temperature Controls Residential ModelsPage Commercial Models Control Wiring Connections Inside Water Heater Initial Operation and Testing of Controls Installer onlySection Viii Operating Instructions To Fill the Water HeaterSequence of Operation Lighting Instructions For Your Safety Read Before Operating To Turn OFF GAS to the ApplianceManual Gas Valve Fig Turning OFF the Water Heater for AN Extended Period of Time Residential Models see FigureMain or Bath Control For Residential Models Fig Commercial Models see FigureMain Control for Commercial Models Fig Approximate TIME/TEMPERATURE Relationships in Scalds First AID for ScaldsError Messages on Remote Temperature Control Display Section IX Maintenance Burner Flame Appearance Fig Page Lime Scale Flushing Diagram Fig Schematic Diagram of Internal Parts Section X Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Parts List Anti-Frost Heater Clip

IGE-199R, IGE-199C specifications

Bradford-White Corp is renowned for its commitment to high-quality water heating and storage solutions, and its IGE-199C and IGE-199R models are prime examples of their innovation in the domain of gas-fired water heaters. These units are designed specifically for commercial applications, catering to restaurants, hotels, and other establishments that require efficient and reliable hot water supply systems.

One of the standout features of the IGE-199C and IGE-199R models is their energy efficiency. Both models utilize advanced technology to ensure minimized energy consumption while maximizing performance. They are equipped with a robust gas burner that delivers rapid heating capabilities, making them ideal for businesses with high demand for hot water. With an Energy Factor rating that meets or exceeds industry standards, users can expect lower operational costs, contributing to overall energy savings.

The IGE-199C is a compact, natural gas-powered unit, engineered for easy installation and integration. Its unique design features a built-in venting system that simplifies the setup process, making it suitable for retrofitting into existing systems. Meanwhile, the IGE-199R model offers similar performance with added versatility, as it can operate on either natural gas or propane, providing flexibility for various installation requirements. Both models are equipped with a powerful heat exchanger that enhances heat transfer efficiency, ensuring consistent delivery of hot water.

Safety and reliability are also central to the IGE-199C and IGE-199R designs. Each unit is fitted with multiple safety features, including high-temperature limit switches and an integrated drain valve, ensuring safe operation under all conditions. The durable construction of these water heaters, with heavy-duty commercial-grade materials, enhances longevity while reducing the likelihood of maintenance issues.

Another notable characteristic is their user-friendly control systems, enabling easy adjustments to temperature settings and monitoring of performance metrics. This ensures that operators can maintain optimal performance levels without extensive training or technical knowledge.

In summary, the Bradford-White IGE-199C and IGE-199R models are state-of-the-art gas-fired water heaters that combine efficiency, safety, and reliability. Their innovative features and technologies make them ideal for demanding commercial applications, providing businesses with an effective solution for their hot water needs. With their focus on durability and performance, these models exemplify Bradford-White's dedication to excellence in water heating technology.