2.To set the desired temperature on the remote control, all hot water faucets must be closed. If there are Bath Controls installed, press the “Priority” button on the control you want to change the setting on and the yellow “Priority” indicator light will glow.
3.Press the “H” or “C” button until the required temperature is displayed on the digital monitor. The Bath Controls have a maximum temperature setting of 120°F, while the Main Control has a maximum setpoint of 160°F.
4.To operate the water heater, simply turn any hot water tap on. This will automatically light the burner and provide hot water at the preset temperature. If the optional remote controls have been installed, the green “IN USE” indicator light will glow on all remote controls.
Main or Bath Control For Residential Models (Fig 6)
NOTICE
The temperature can only be adjusted between 96°F and 110°F when the hot water tap is open and hot water is flowing. This is a safety feature to prevent scalding while hot water is in use.
Commercial Models (see Figure 7):
1.Commercial models are supplied in the water heater carton with a Remote Main Control, which will allow the outlet water temperature to be adjusted from
2.All hot water faucets must be off to get the full range of temperature adjustment. The control will only allow an adjustment range of
3.Press the “H” or “C” buttons until the desired temperature is shown on the display.
4.The water heater will automatically start heating water whenever a hot water faucet is opened. The remote temperature control will indicate hot water use with the green “IN USE” indicator.
5.The Remote Main Control can also display diagnostic error codes, water flow rate through the unit (in gallons per minute) and the outlet water temperature.