Bradford-White Corp IGE-199R, IGE-199C Main or Bath Control For Residential Models Fig

Page 32

2.To set the desired temperature on the remote control, all hot water faucets must be closed. If there are Bath Controls installed, press the “Priority” button on the control you want to change the setting on and the yellow “Priority” indicator light will glow.

3.Press the “H” or “C” button until the required temperature is displayed on the digital monitor. The Bath Controls have a maximum temperature setting of 120°F, while the Main Control has a maximum setpoint of 160°F.

4.To operate the water heater, simply turn any hot water tap on. This will automatically light the burner and provide hot water at the preset temperature. If the optional remote controls have been installed, the green “IN USE” indicator light will glow on all remote controls.

Main or Bath Control For Residential Models (Fig 6)

NOTICE

The temperature can only be adjusted between 96°F and 110°F when the hot water tap is open and hot water is flowing. This is a safety feature to prevent scalding while hot water is in use.

Commercial Models (see Figure 7):

1.Commercial models are supplied in the water heater carton with a Remote Main Control, which will allow the outlet water temperature to be adjusted from 96-180°F. Commercial models can only have one remote control.

2.All hot water faucets must be off to get the full range of temperature adjustment. The control will only allow an adjustment range of 96-110°F while hot water is in use to prevent scalds.

3.Press the “H” or “C” buttons until the desired temperature is shown on the display.

4.The water heater will automatically start heating water whenever a hot water faucet is opened. The remote temperature control will indicate hot water use with the green “IN USE” indicator.

5.The Remote Main Control can also display diagnostic error codes, water flow rate through the unit (in gallons per minute) and the outlet water temperature.

32

Image 32
Contents IGE-199R and IGE-199C Model Series Section I Important Information Read CarefullyPage Do not Operate the Appliance Until the Leakage is Corrected Table of Contents Section II Specifications IGE-199R-10XEVERHOT→ IGE Model Series Dimensions Features Section III General InformationSection IV Installation Instructions Do not Operate the Appliance Until the Leakage is CorrectedUnpacking Water Heater LocationBuild Opening Clearances Fig Reference Description Minimum Distance Inches cmRemove Carton Mount Water Heater on the WallLime Condition Warning Signal Section V Water ConnectionsWater Quality Instructions for ConnectionsPage Recommended Piping for a Basic Installation Recommended Piping for Power Failure Freeze Protection Drain Solenoid Piping FigRecommended Piping for a Circulation System Page Pressure Relief Valve Never USE a Match or Open Flame for Testing Section VI GAS ConnectionsGAS Pressure Regulation Initial Operation and Testing Installer onlyGAS Meter Size -NATURALGAS only Page Section VII Electrical Connections Wiring Diagram Wiring Diagram Schematic Remote Temperature Controls Residential ModelsPage Commercial Models Control Wiring Connections Inside Water Heater Initial Operation and Testing of Controls Installer only Sequence of Operation Section Viii Operating Instructions To Fill the Water Heater Manual Gas Valve Fig Lighting Instructions For Your Safety Read Before OperatingTo Turn OFF GAS to the Appliance Turning OFF the Water Heater for AN Extended Period of Time Residential Models see FigureMain or Bath Control For Residential Models Fig Commercial Models see FigureMain Control for Commercial Models Fig Approximate TIME/TEMPERATURE Relationships in Scalds First AID for ScaldsError Messages on Remote Temperature Control Display Section IX Maintenance Burner Flame Appearance Fig Page Lime Scale Flushing Diagram Fig Schematic Diagram of Internal Parts Section X Parts List Exploded View Internal Components Exploded View Internal Components Exploded View Electrical Parts List Anti-Frost Heater Clip