A.O. Smith 317443-000, 100 Power Vent DV Series 120 instruction manual Table of contents

Page 2

table of contents

table of contents

2

Applicators

31

safe installation, use and service

3

Controls and Switches

33

APPROVALS

3

Blower Prover Switch

33

general safety information

4

Blocked Exhaust Switch

33

Precautions

4

Blocked Intake Switch

33

Grounding Instructions

4

On/Off Switch

33

Hydrogen Gas Flammable

4

Hot Surface Igniter

33

troubleshooting

6

temperature regulation

36

introduction

7

Hi Limit Switch (E.C.O.)

36

Abbreviations Used

7

control system operation

37

Qualifications

7

Overview

37

Qualified Installer or Service Agency

7

Commercial And Residential Models

37

iCOMM™ & BACnet Compatible

7

Control System Navigation

37

Preparing For The Installation

7

User Input Buttons

37

features and components

8

The Desktop Screen

37

installation consideration

9

Status Icons

38

Rough in Dimensions

9

Operating States

39

Locating The Water Heater

10

Control System Menus

39

Insulation Blankets

11

User Settings & Control System Menus

40

Combustion Air and Ventilation

11

Temperatures

40

Unconfined Space

11

Operating Set Point And Differential Adjustment

40

Unusually Tight Construction

12

Temperatures (cont)

41

Confined Space

12

Heater Status

41

Direct Vent Appliances

12

Display Settings

42

Exhaust Fans

12

Heater Information

42

Louvers and Grilles

12

Current Fault

43

Fresh Air Openings For Confined Spaces

12

Fault History

43

Outdoor Air Through Two Openings

12

Fault Occurrence

43

Outdoor Air Through One Opening

12

Restore Factory Defaults

43

Outdoor Air Through Two Horizontal Ducts

13

Service Contact Information

44

Air From Other Indoor Spaces

13

for your information

45

installing the new water heater

14

Start Up Conditions

45

Chemical Vapor Corrosion

14

Smoke/Odor

45

Water Piping

14

Thermal Expansion

45

Power Supply

14

Operational Conditions

45

Power Fluctuations and Electrical Noise

14

Smelly Water

45

Dedicated Power Wiring and Breakers

14

“Air” in Hot Water Faucet

45

Polarity Sensitive

14

periodic maintenance

46

Mixing Valves

15

Venting System Inspection

46

Dishwashing Machines

15

Anode Rod Inspection

46

Space Heating and Potable Water System

15

Temperature-Pressure Relief Valve Operation

46

Closed Water Systems

15

Draining and Flushing

46

Thermal Expansion

16

To Drain the Water Heater Storage Tank

47

Temperature-Pressure Relief Valve

17

To Flush the Water Heater Storage Tank

47

T&P Valve Discharge Pipe Requirements:

17

Service

47

Gas Piping

18

maintenance

48

Condensate Piping

18

Temperature-Pressure Relief Valve Test

48

High Altitude Installations

19

leakage checkpoints

49

Sediment Traps

19

troubleshooting

50

Filling the Water Heater

19

Installation Checklist

50

Venting

20

Water Heater Location

50

Vent Pipe Termination

20

Venting

50

Planning the Vent System

20

Gas Supply and Piping

50

Installation of Vent System

21

Condensate Drain

50

Vent Terminal Installation, Sidewall

21

Electrical Connections

50

Installation Requirements - Commonwealth of Massachusetts....

22

Sequence Of Operation Flow Chart

51

Termination Clearances Sidewall Power Vent

23

Operational Problems

52

Termination Clearances Sidewall Direct Vent

24

Rough Starting, Rough Operation

52

Sequence of Installations, Figure 18A

25

Momentary Ignition

52

Direct Vent Terminal Installation

25

Not Enough Or No Hot Water

52

Installation Sequence

25

Water Is Too Hot

52

Vent Terminals Supplied with Heater Must be Used

25

Noisy Operation

52

Vertical Vent Terminal Installation

26

Replacement Parts

52

Concentric Vent Installation

27

Fault and Alert Conditions

52

Kit Components

27

Fault Conditions

52

Safety Considerations

27

Alert Conditions

52

Installation Procedure 1 Roof Termination, see Figure C

27

Resetting Control System Lock Outs

53

direct vent diagram

30

Diagnostic Checks

53

Vent Pipe Preparation

31

Fault and Alert Messages

54

Primer

31

notes

56

Primer and Cement

31

Limited Warranty

59

2

Image 2
Contents 317443-000 Whenever maintenance adjustment or service is requiredPrinted Table of contents Safe installation, use and service ApprovalsGrounding Instructions General safety informationPrecautions Hydrogen Gas Flammable General safety information Fire or Explosion Hazard Abbreviations Used Preparing For The InstallationIntroduction QualificationsFeatures and components Replacement Parts and Deliming ProductsRough-In-Dimensions Installation considerationRough in Dimensions Recovery capacity based on 96% thermal efficiencyProperty Damage Hazard Locating The Water HeaterUnconfined Space Combustion AIR and VentilationInsulation Blankets Outdoor Air Through Two Openings Confined SpaceFresh Air Openings For Confined Spaces Outdoor Air Through One OpeningOutdoor Air Through Two Horizontal Ducts Air From Other Indoor SpacesChemical Vapor Corrosion Installing the new water heaterPower Supply Water PipingSpace heating and potable water system Mixing ValvesDishwashing Machines Valve and Pipe Insulation if supplied Closed Water SystemsThermal Expansion Temperature-Pressure Relief Valve Valve Discharge Pipe RequirementsGas piping Condensate PipingHigh Altitude Installations Sediment Traps Filling the Water HeaterPlanning the Vent System VentingVent Pipe Termination Installation of Vent System Vent Terminal INSTALLATION, SidewallApproved Carbon Monoxide Detectors Installation Requirements Commonwealth of MassachusettsInstallation of Carbon Monoxide Detectors SignageTermination Clearances Sidewall Power Vent Power VentTermination Clearances Sidewall Direct Vent Direct VentVent Termination a Direct Vent terminal installation Installation SequenceSequence of INSTALLATIONS, a Vent Terminals Supplied with Heater Must be UsedFlat Roof Installation KIT Components Concentric vent installationSafety Considerations Description QtyConcentric Termination Flat Roof Clearance MULTI-CONCENTRIC Vent Terminations Direct vent diagram Vent Pipe Preparation Step F Step BStep E Step GBlocked Intake Switch Blower Prover SwitchBlocked Exhaust Switch ON/OFF SwitchPower Vent Wiring Schematic Figure Do not TRY to Light the Burner by Hand Do not try to light the burner by handWhat to do if YOU Smell GAS Temperature regulation HI Limit Switch ECOControl System Navigation Control system operationOverview Icon Description Status IconsOperating States Control System MenusUser Settings & Control System Menus Temperatures Operating Set Point And Differential AdjustmentECO Contact , Blocked Inlet PS , Blocked Outlet PS , Blower TemperaturesHeater Status Blower Low On , Blower High On displays whetherDisplay Settings Heater InformationFault Occurrence Current FaultFault History Restore Factory DefaultsService Contact Information Service Contact InformationOperational Conditions For your informationStart UP Conditions Venting System Inspection Periodic maintenanceTemperature-Pressure Relief Valve Operation Anode ROD InspectionTo Flush the Water Heater Storage Tank ServiceTo drain the water heater storage tank Maintenance Temperature-Pressure Relief Valve TestLeakage checkpoints Troubleshooting Installation ChecklistSequence Of Operation Flow Chart YES noOperational Problems Fault And Alert ConditionsResetting Control System Lock Outs Diagnostic ChecksFault And Alert Messages AC ReversedBlower Prover Failure Page Page Page Limited Warranty Fill in Warranty and Keep for Future Reference

100 Power Vent DV Series 120, 317443-000 specifications

The A.O. Smith 317443-000,100 Power Vent DV Series 120 is an advanced water heating solution designed to enhance efficiency and performance for residential applications. As part of A.O. Smith's renowned lineup, this model embodies the company's commitment to innovation and energy conservation.

One of the main features of the DV Series 120 is its power venting capability. This technology allows for flexible installation options, as it can vent vertically or horizontally, accommodating various home configurations. It utilizes a fan-assisted venting system, which efficiently expels exhaust gases, ensuring safe operation even in tight spaces.

The unit's energy efficiency is another standout characteristic. Equipped with a high-efficiency gas burner, the DV Series 120 optimizes fuel consumption, resulting in lower utility bills while providing reliable hot water when needed. Its impressive Energy Factor (EF) ratings make it an environmentally friendly choice, aligning with modern standards for green building practices.

Durability is also a significant focus of the A.O. Smith 317443-000,100 Power Vent model. Constructed with a glass-lined tank and a robust anode rod, this water heater is designed to resist corrosion and extend its lifespan. This construction enhances performance reliability while minimizing maintenance needs, making it a smart investment for homeowners.

Smart technologies are integrated into the DV Series 120, featuring an intelligent control system that provides various operational insights. The built-in diagnostic features allow homeowners to monitor performance and identify potential issues early, reducing the likelihood of unexpected failures. This control system can also enable more precise temperature management, enhancing both comfort and efficiency.

Safety is paramount in the design of the A.O. Smith 317443-000,100. The unit comes equipped with safety features such as a built-in flame rollout sensor and an automatic shut-off system to protect against potential hazards. These features ensure peace of mind for users, allowing them to confidently rely on their hot water supply.

In summary, the A.O. Smith 317443-000,100 Power Vent DV Series 120 stands out as a high-efficiency water heating solution, combining innovative venting technologies, durability, smart features, and safety mechanisms. This model is an ideal choice for homeowners seeking a reliable and efficient hot water system that meets modern energy standards.