A.O. Smith 317443-000 General safety information, Precautions Hydrogen Gas Flammable

Page 4

general safety information

Precautions

 

Hydrogen Gas Flammable

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service agency to inspect the appliance and to make a determination on what steps should be taken next.

If the unit is exposed to the following, do not operate heater until all corrective steps have been made by a qualified service agency.

1.External fire.

2.Damage.

3.Firing without water.

Explosion Hazard

Flammable hydrogen gases may be present.

Keep all ignition sources away from faucet when turning on hot water.

GROUNDING INSTRUCTIONS

This water heater must be grounded in accordance with the National Electrical Code and/or local codes. These must be followed in all cases. Failure to ground this water heater properly may also cause erratic control system operation.

This water heater must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the water heater.

Hydrogen gas can be produced in a hot water system served by this appliance that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that a hot water faucet served by this appliance be opened for several minutes before using any electrical appliance connected to the hot water system. If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open.

Verify the power to the water heater is turned off before performing any service procedures.

Read and understand this instruction manual and the safety messages herein before installing, operating or servicing this water heater.

Failure to follow these instructions and safety messages could result in death or serious injury.

This manual must remain with the water heater.

Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death.

Children, the elderly and the physically or mentally disabled are at highest risk for scald injury.

Feel water before bathing or showering.

Temperature limiting devices such as mixing valves must be installed when required by codes and to ensure safe temperatures at fixtures.

Explosion Hazard

Overheated water can cause water tank explosion.

Properly sized temperature and pressure relief valve must be installed in the opening provided.

CAUTION

Improper installation, use and service may result

in property damage.

Do not operate water heater if flood damaged.

Inspect and anode rods regularly, replace if damaged.

Install in location with drainage.

Fill tank with water before operation.

Properly sized thermal expansion tanks are required on all closed water systems.

Refer to this manual for installation and service.

4

Image 4
Contents Printed Whenever maintenance adjustment or service is required317443-000 Table of contents Safe installation, use and service ApprovalsPrecautions Hydrogen Gas Flammable General safety informationGrounding Instructions General safety information Fire or Explosion Hazard Preparing For The Installation IntroductionAbbreviations Used QualificationsFeatures and components Replacement Parts and Deliming ProductsInstallation consideration Rough in DimensionsRough-In-Dimensions Recovery capacity based on 96% thermal efficiencyProperty Damage Hazard Locating The Water HeaterInsulation Blankets Combustion AIR and VentilationUnconfined Space Confined Space Fresh Air Openings For Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through One OpeningOutdoor Air Through Two Horizontal Ducts Air From Other Indoor SpacesInstalling the new water heater Power SupplyChemical Vapor Corrosion Water PipingDishwashing Machines Mixing ValvesSpace heating and potable water system Thermal Expansion Closed Water SystemsValve and Pipe Insulation if supplied Temperature-Pressure Relief Valve Valve Discharge Pipe RequirementsGas piping Condensate PipingHigh Altitude Installations Sediment Traps Filling the Water HeaterVent Pipe Termination VentingPlanning the Vent System Installation of Vent System Vent Terminal INSTALLATION, SidewallInstallation Requirements Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsApproved Carbon Monoxide Detectors SignageTermination Clearances Sidewall Power Vent Power VentTermination Clearances Sidewall Direct Vent Direct VentInstallation Sequence Sequence of INSTALLATIONS, aVent Termination a Direct Vent terminal installation Vent Terminals Supplied with Heater Must be UsedFlat Roof Installation Concentric vent installation Safety ConsiderationsKIT Components Description QtyConcentric Termination Flat Roof Clearance MULTI-CONCENTRIC Vent Terminations Direct vent diagram Vent Pipe Preparation Step B Step EStep F Step GBlower Prover Switch Blocked Exhaust SwitchBlocked Intake Switch ON/OFF SwitchPower Vent Wiring Schematic Figure What to do if YOU Smell GAS Do not try to light the burner by handDo not TRY to Light the Burner by Hand Temperature regulation HI Limit Switch ECOOverview Control system operationControl System Navigation Icon Description Status IconsOperating States Control System MenusUser Settings & Control System Menus Temperatures Operating Set Point And Differential AdjustmentTemperatures Heater StatusECO Contact , Blocked Inlet PS , Blocked Outlet PS , Blower Blower Low On , Blower High On displays whetherDisplay Settings Heater InformationCurrent Fault Fault HistoryFault Occurrence Restore Factory DefaultsService Contact Information Service Contact InformationStart UP Conditions For your informationOperational Conditions Periodic maintenance Temperature-Pressure Relief Valve OperationVenting System Inspection Anode ROD InspectionTo drain the water heater storage tank ServiceTo Flush the Water Heater Storage Tank Maintenance Temperature-Pressure Relief Valve TestLeakage checkpoints Troubleshooting Installation ChecklistSequence Of Operation Flow Chart YES noOperational Problems Fault And Alert ConditionsResetting Control System Lock Outs Diagnostic ChecksFault And Alert Messages AC ReversedBlower Prover Failure Page Page Page Limited Warranty Fill in Warranty and Keep for Future Reference

100 Power Vent DV Series 120, 317443-000 specifications

The A.O. Smith 317443-000,100 Power Vent DV Series 120 is an advanced water heating solution designed to enhance efficiency and performance for residential applications. As part of A.O. Smith's renowned lineup, this model embodies the company's commitment to innovation and energy conservation.

One of the main features of the DV Series 120 is its power venting capability. This technology allows for flexible installation options, as it can vent vertically or horizontally, accommodating various home configurations. It utilizes a fan-assisted venting system, which efficiently expels exhaust gases, ensuring safe operation even in tight spaces.

The unit's energy efficiency is another standout characteristic. Equipped with a high-efficiency gas burner, the DV Series 120 optimizes fuel consumption, resulting in lower utility bills while providing reliable hot water when needed. Its impressive Energy Factor (EF) ratings make it an environmentally friendly choice, aligning with modern standards for green building practices.

Durability is also a significant focus of the A.O. Smith 317443-000,100 Power Vent model. Constructed with a glass-lined tank and a robust anode rod, this water heater is designed to resist corrosion and extend its lifespan. This construction enhances performance reliability while minimizing maintenance needs, making it a smart investment for homeowners.

Smart technologies are integrated into the DV Series 120, featuring an intelligent control system that provides various operational insights. The built-in diagnostic features allow homeowners to monitor performance and identify potential issues early, reducing the likelihood of unexpected failures. This control system can also enable more precise temperature management, enhancing both comfort and efficiency.

Safety is paramount in the design of the A.O. Smith 317443-000,100. The unit comes equipped with safety features such as a built-in flame rollout sensor and an automatic shut-off system to protect against potential hazards. These features ensure peace of mind for users, allowing them to confidently rely on their hot water supply.

In summary, the A.O. Smith 317443-000,100 Power Vent DV Series 120 stands out as a high-efficiency water heating solution, combining innovative venting technologies, durability, smart features, and safety mechanisms. This model is an ideal choice for homeowners seeking a reliable and efficient hot water system that meets modern energy standards.