A.O. Smith 100 Power Vent DV Series 120 Installation consideration, Rough in Dimensions

Page 9

installation consideration

ROUGH IN DIMENSIONS

FIGURE 1A.

Rough-In-Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units

 

 

A

 

B

 

C

 

 

D

 

 

E

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inches

 

66.75

 

49.25

 

22.00

 

15.75

 

3.00

 

8.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cm

 

169.5

 

125.09

 

55.88

 

40.00

 

7.62

 

20.32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top/Side Inlet and Outlet: 3/4” NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Inlet: 1/2” NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity, Gas and Electrical Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approximate Capacity

 

 

Manifold Pressure

 

Electrical Characteristics

 

 

 

 

 

 

 

 

 

U.S. Gals.

 

Liters

 

Gas Type

 

“WC

 

kPA

 

Volts/Hz

Amperes

 

 

 

 

 

 

 

 

 

50

 

 

 

189

 

 

 

Nat./LP

 

 

0”

 

 

0”

 

120/60

 

 

 

<5

 

 

 

 

 

 

 

 

 

Maximum Supply Pressure: 14 inches W.C. (3.48kPa)

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure for Natural Gas: 3.50” (.87kPa)

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure for Propane Gas: 8.00” (1.99kPa)

 

 

 

 

 

 

 

 

 

 

 

 

Minimum pressure must be maintained under both load and no load (dynamic and static) conditions.

 

 

 

Recovery Capacities - U.S. Gallons/Hr. and Liters/Hr. at Temperature Rise Indicated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery Capacities

 

 

 

 

 

 

Rating

 

Rating

 

Temp.

F

 

30

 

 

40

 

50

 

 

60

 

70

 

80

 

90

100

110

120

130

140

(Btu/hr)

 

(kW)

 

Rise

 

C

 

17

 

 

22

 

28

 

 

33

 

39

 

44

 

50

56

61

67

72

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100,000

 

29.3

 

 

 

GPH

 

 

387

 

 

291

 

233

 

 

194

 

166

145

 

129

116

106

97

90

83

 

 

 

 

LPH

 

 

1465

 

1102

 

882

 

 

734

 

628

549

 

488

439

401

367

341

314

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery capacity based on 96% thermal efficiency

9

Image 9
Contents Whenever maintenance adjustment or service is required Printed317443-000 Table of contents Approvals Safe installation, use and serviceGeneral safety information Precautions Hydrogen Gas FlammableGrounding Instructions General safety information Fire or Explosion Hazard Introduction Preparing For The InstallationAbbreviations Used QualificationsReplacement Parts and Deliming Products Features and componentsRough in Dimensions Installation considerationRough-In-Dimensions Recovery capacity based on 96% thermal efficiencyLocating The Water Heater Property Damage HazardCombustion AIR and Ventilation Insulation BlanketsUnconfined Space Fresh Air Openings For Confined Spaces Confined SpaceOutdoor Air Through Two Openings Outdoor Air Through One OpeningAir From Other Indoor Spaces Outdoor Air Through Two Horizontal DuctsPower Supply Installing the new water heaterChemical Vapor Corrosion Water PipingMixing Valves Dishwashing MachinesSpace heating and potable water system Closed Water Systems Thermal ExpansionValve and Pipe Insulation if supplied Valve Discharge Pipe Requirements Temperature-Pressure Relief ValveCondensate Piping Gas pipingFilling the Water Heater High Altitude Installations Sediment TrapsVenting Vent Pipe TerminationPlanning the Vent System Vent Terminal INSTALLATION, Sidewall Installation of Vent SystemInstallation of Carbon Monoxide Detectors Installation Requirements Commonwealth of MassachusettsApproved Carbon Monoxide Detectors SignagePower Vent Termination Clearances Sidewall Power VentDirect Vent Termination Clearances Sidewall Direct VentSequence of INSTALLATIONS, a Installation SequenceVent Termination a Direct Vent terminal installation Vent Terminals Supplied with Heater Must be UsedFlat Roof Installation Safety Considerations Concentric vent installationKIT Components Description QtyConcentric Termination Flat Roof Clearance MULTI-CONCENTRIC Vent Terminations Direct vent diagram Vent Pipe Preparation Step E Step BStep F Step GBlocked Exhaust Switch Blower Prover SwitchBlocked Intake Switch ON/OFF SwitchPower Vent Wiring Schematic Figure Do not try to light the burner by hand What to do if YOU Smell GASDo not TRY to Light the Burner by Hand HI Limit Switch ECO Temperature regulationControl system operation OverviewControl System Navigation Status Icons Icon DescriptionControl System Menus Operating StatesTemperatures Operating Set Point And Differential Adjustment User Settings & Control System MenusHeater Status TemperaturesECO Contact , Blocked Inlet PS , Blocked Outlet PS , Blower Blower Low On , Blower High On displays whetherHeater Information Display SettingsFault History Current FaultFault Occurrence Restore Factory DefaultsService Contact Information Service Contact InformationFor your information Start UP ConditionsOperational Conditions Temperature-Pressure Relief Valve Operation Periodic maintenanceVenting System Inspection Anode ROD InspectionService To drain the water heater storage tankTo Flush the Water Heater Storage Tank Temperature-Pressure Relief Valve Test MaintenanceLeakage checkpoints Installation Checklist TroubleshootingYES no Sequence Of Operation Flow ChartFault And Alert Conditions Operational ProblemsDiagnostic Checks Resetting Control System Lock OutsAC Reversed Fault And Alert MessagesBlower Prover Failure Page Page Page Fill in Warranty and Keep for Future Reference Limited Warranty

100 Power Vent DV Series 120, 317443-000 specifications

The A.O. Smith 317443-000,100 Power Vent DV Series 120 is an advanced water heating solution designed to enhance efficiency and performance for residential applications. As part of A.O. Smith's renowned lineup, this model embodies the company's commitment to innovation and energy conservation.

One of the main features of the DV Series 120 is its power venting capability. This technology allows for flexible installation options, as it can vent vertically or horizontally, accommodating various home configurations. It utilizes a fan-assisted venting system, which efficiently expels exhaust gases, ensuring safe operation even in tight spaces.

The unit's energy efficiency is another standout characteristic. Equipped with a high-efficiency gas burner, the DV Series 120 optimizes fuel consumption, resulting in lower utility bills while providing reliable hot water when needed. Its impressive Energy Factor (EF) ratings make it an environmentally friendly choice, aligning with modern standards for green building practices.

Durability is also a significant focus of the A.O. Smith 317443-000,100 Power Vent model. Constructed with a glass-lined tank and a robust anode rod, this water heater is designed to resist corrosion and extend its lifespan. This construction enhances performance reliability while minimizing maintenance needs, making it a smart investment for homeowners.

Smart technologies are integrated into the DV Series 120, featuring an intelligent control system that provides various operational insights. The built-in diagnostic features allow homeowners to monitor performance and identify potential issues early, reducing the likelihood of unexpected failures. This control system can also enable more precise temperature management, enhancing both comfort and efficiency.

Safety is paramount in the design of the A.O. Smith 317443-000,100. The unit comes equipped with safety features such as a built-in flame rollout sensor and an automatic shut-off system to protect against potential hazards. These features ensure peace of mind for users, allowing them to confidently rely on their hot water supply.

In summary, the A.O. Smith 317443-000,100 Power Vent DV Series 120 stands out as a high-efficiency water heating solution, combining innovative venting technologies, durability, smart features, and safety mechanisms. This model is an ideal choice for homeowners seeking a reliable and efficient hot water system that meets modern energy standards.