A.O. Smith 100 Power Vent DV Series 120, 317443-000 Do not try to light the burner by hand

Page 35

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner.

Do NOT try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because

some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in the gas control buttons. Never use tools. If the control buttons will not push in, don’t try to repair them, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

OPERATING INSTRUCTIONS

 

 

UP

Operating Set Point

120

F

Status: Heating

 

 

OFF

 

 

GAS

O

 

 

N

 

Menu

Help

DN

 

ON/OFF SWITCH

1.STOP! Read the safety information above, on this label.

2.Set the ON/OFF switch on the control panel to the “ON” position.

3.Set the thermostat to the lowest setting.

4.Set the ON/OFF switch on the control box to the

“OFF” position.

5.This appliance is equipped with a device which automatically lights the burner.

DO NOT TRY TO LIGHT THE BURNER BY HAND.

6. Wait five (5) minutes to

clear out any

gas. If you smell gas,

STOP! Follow “B”

in the safety information above on this label. If you don’t smell gas.

7.Turn on all electrical power to the appliance.

8.Set the ON/OFF switch on the control box to the

“ON” position.

9.Set the thermostat to the desired setting.

CAUTION: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.

10.If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your technician or gas supplier.

WARNING: TURN OFF ALL ELECTRIC POWER BEFORE SERVICING

TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to the lowest setting.

2.Set the ON/OFF switch on the control panel to the

“OFF” position.

3.Turn off all electrical power to the appliance if service is to be performed.

35

Image 35
Contents 317443-000 Whenever maintenance adjustment or service is requiredPrinted Table of contents Approvals Safe installation, use and serviceGrounding Instructions General safety informationPrecautions Hydrogen Gas Flammable General safety information Fire or Explosion Hazard Qualifications Preparing For The InstallationIntroduction Abbreviations UsedReplacement Parts and Deliming Products Features and componentsRecovery capacity based on 96% thermal efficiency Installation considerationRough in Dimensions Rough-In-DimensionsLocating The Water Heater Property Damage HazardUnconfined Space Combustion AIR and VentilationInsulation Blankets Outdoor Air Through One Opening Confined SpaceFresh Air Openings For Confined Spaces Outdoor Air Through Two OpeningsAir From Other Indoor Spaces Outdoor Air Through Two Horizontal DuctsWater Piping Installing the new water heaterPower Supply Chemical Vapor CorrosionSpace heating and potable water system Mixing ValvesDishwashing Machines Valve and Pipe Insulation if supplied Closed Water SystemsThermal Expansion Valve Discharge Pipe Requirements Temperature-Pressure Relief ValveCondensate Piping Gas pipingFilling the Water Heater High Altitude Installations Sediment TrapsPlanning the Vent System VentingVent Pipe Termination Vent Terminal INSTALLATION, Sidewall Installation of Vent SystemSignage Installation Requirements Commonwealth of MassachusettsInstallation of Carbon Monoxide Detectors Approved Carbon Monoxide DetectorsPower Vent Termination Clearances Sidewall Power VentDirect Vent Termination Clearances Sidewall Direct VentVent Terminals Supplied with Heater Must be Used Installation SequenceSequence of INSTALLATIONS, a Vent Termination a Direct Vent terminal installationFlat Roof Installation Description Qty Concentric vent installationSafety Considerations KIT ComponentsConcentric Termination Flat Roof Clearance MULTI-CONCENTRIC Vent Terminations Direct vent diagram Vent Pipe Preparation Step G Step BStep E Step FON/OFF Switch Blower Prover SwitchBlocked Exhaust Switch Blocked Intake SwitchPower Vent Wiring Schematic Figure Do not TRY to Light the Burner by Hand Do not try to light the burner by handWhat to do if YOU Smell GAS HI Limit Switch ECO Temperature regulationControl System Navigation Control system operationOverview Status Icons Icon DescriptionControl System Menus Operating StatesTemperatures Operating Set Point And Differential Adjustment User Settings & Control System MenusBlower Low On , Blower High On displays whether TemperaturesHeater Status ECO Contact , Blocked Inlet PS , Blocked Outlet PS , BlowerHeater Information Display SettingsRestore Factory Defaults Current FaultFault History Fault OccurrenceService Contact Information Service Contact InformationOperational Conditions For your informationStart UP Conditions Anode ROD Inspection Periodic maintenanceTemperature-Pressure Relief Valve Operation Venting System InspectionTo Flush the Water Heater Storage Tank ServiceTo drain the water heater storage tank Temperature-Pressure Relief Valve Test MaintenanceLeakage checkpoints Installation Checklist TroubleshootingYES no Sequence Of Operation Flow ChartFault And Alert Conditions Operational ProblemsDiagnostic Checks Resetting Control System Lock OutsAC Reversed Fault And Alert MessagesBlower Prover Failure Page Page Page Fill in Warranty and Keep for Future Reference Limited Warranty

100 Power Vent DV Series 120, 317443-000 specifications

The A.O. Smith 317443-000,100 Power Vent DV Series 120 is an advanced water heating solution designed to enhance efficiency and performance for residential applications. As part of A.O. Smith's renowned lineup, this model embodies the company's commitment to innovation and energy conservation.

One of the main features of the DV Series 120 is its power venting capability. This technology allows for flexible installation options, as it can vent vertically or horizontally, accommodating various home configurations. It utilizes a fan-assisted venting system, which efficiently expels exhaust gases, ensuring safe operation even in tight spaces.

The unit's energy efficiency is another standout characteristic. Equipped with a high-efficiency gas burner, the DV Series 120 optimizes fuel consumption, resulting in lower utility bills while providing reliable hot water when needed. Its impressive Energy Factor (EF) ratings make it an environmentally friendly choice, aligning with modern standards for green building practices.

Durability is also a significant focus of the A.O. Smith 317443-000,100 Power Vent model. Constructed with a glass-lined tank and a robust anode rod, this water heater is designed to resist corrosion and extend its lifespan. This construction enhances performance reliability while minimizing maintenance needs, making it a smart investment for homeowners.

Smart technologies are integrated into the DV Series 120, featuring an intelligent control system that provides various operational insights. The built-in diagnostic features allow homeowners to monitor performance and identify potential issues early, reducing the likelihood of unexpected failures. This control system can also enable more precise temperature management, enhancing both comfort and efficiency.

Safety is paramount in the design of the A.O. Smith 317443-000,100. The unit comes equipped with safety features such as a built-in flame rollout sensor and an automatic shut-off system to protect against potential hazards. These features ensure peace of mind for users, allowing them to confidently rely on their hot water supply.

In summary, the A.O. Smith 317443-000,100 Power Vent DV Series 120 stands out as a high-efficiency water heating solution, combining innovative venting technologies, durability, smart features, and safety mechanisms. This model is an ideal choice for homeowners seeking a reliable and efficient hot water system that meets modern energy standards.