A.O. Smith 100 Power Vent DV Series 120 Service, To drain the water heater storage tank

Page 47

Burn harzard.

Hot water discharge.

Keep hands clear of drain valve discharge.

To drain the water heater storage tank:

1.Turn off the electrical supply to the water heater.

2.Turn off the gas supply at the Main Gas Shutoff Valve if the water heater is going to be shut down for an extended period.

3.Ensure the cold water inlet valve is open.

4.Open a nearby hot water faucet and let the water run until the water is no longer hot.

5.Close the cold water inlet valve to the water heater.

6.Connect a hose to the water heater drain valve and terminate it to an adequate drain.

7.Open the water heater drain valve and allow all the water to drain from the storage tank.

8.Close the water heater drain valve when all water in the storage tank has drained.

9.Close the hot water faucet opened in Step 4.

10.If the water heater is going to be shut down for an extended period, the drain valve should be left open.

To Flush the Water Heater Storage Tank:

11. Turn off the electrical supply to the water heater.

12.Ensure the cold water inlet valve is open.

13.Open a nearby hot water faucet and let the water run until the water is no longer hot. Then close the hot water faucet.

14.Connect a hose to the drain valve and terminate it to an adequate drain.

15.Ensure the drain hose is secured before and during the entire flushing procedure. Flushing is performed with system water pressure applied to the water heater.

16.Open the water heater drain valve to flush the storage tank.

17.Flush the water heater storage tank to remove sediment and allow the water to flow until it runs clean.

18.Close the water heater drain valve when flushing is completed.

19.Remove the drain hose.

20.Fill the water heater - see Filling The Water Heater in this manual.

21.Turn on the electrical supply to place the water heater back in operation.

22.Allow the water heater to complete several heating cycles to ensure it is operating properly.

Service

If a condition persists or you are uncertain about the operation of the water heater contact a qualified service agency.

Use this guide to check a “Leaking” water heater. Many suspected “Leakers” are not leaking tanks. Often the source of the water can be found and corrected.

If you are not thoroughly familiar with gas codes, your water heater, and safety practices, contact your gas supplier or qualified installer to check the water heater.

Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.

47

Image 47
Contents 317443-000 Whenever maintenance adjustment or service is requiredPrinted Table of contents Approvals Safe installation, use and serviceGrounding Instructions General safety informationPrecautions Hydrogen Gas Flammable General safety information Fire or Explosion Hazard Qualifications Preparing For The InstallationIntroduction Abbreviations UsedReplacement Parts and Deliming Products Features and componentsRecovery capacity based on 96% thermal efficiency Installation considerationRough in Dimensions Rough-In-DimensionsLocating The Water Heater Property Damage HazardUnconfined Space Combustion AIR and VentilationInsulation Blankets Outdoor Air Through One Opening Confined SpaceFresh Air Openings For Confined Spaces Outdoor Air Through Two OpeningsAir From Other Indoor Spaces Outdoor Air Through Two Horizontal DuctsWater Piping Installing the new water heaterPower Supply Chemical Vapor CorrosionSpace heating and potable water system Mixing ValvesDishwashing Machines Valve and Pipe Insulation if supplied Closed Water SystemsThermal Expansion Valve Discharge Pipe Requirements Temperature-Pressure Relief ValveCondensate Piping Gas pipingFilling the Water Heater High Altitude Installations Sediment TrapsPlanning the Vent System VentingVent Pipe Termination Vent Terminal INSTALLATION, Sidewall Installation of Vent SystemSignage Installation Requirements Commonwealth of MassachusettsInstallation of Carbon Monoxide Detectors Approved Carbon Monoxide DetectorsPower Vent Termination Clearances Sidewall Power VentDirect Vent Termination Clearances Sidewall Direct VentVent Terminals Supplied with Heater Must be Used Installation SequenceSequence of INSTALLATIONS, a Vent Termination a Direct Vent terminal installationFlat Roof Installation Description Qty Concentric vent installationSafety Considerations KIT ComponentsConcentric Termination Flat Roof Clearance MULTI-CONCENTRIC Vent Terminations Direct vent diagram Vent Pipe Preparation Step G Step BStep E Step FON/OFF Switch Blower Prover SwitchBlocked Exhaust Switch Blocked Intake SwitchPower Vent Wiring Schematic Figure Do not TRY to Light the Burner by Hand Do not try to light the burner by handWhat to do if YOU Smell GAS HI Limit Switch ECO Temperature regulationControl System Navigation Control system operationOverview Status Icons Icon DescriptionControl System Menus Operating StatesTemperatures Operating Set Point And Differential Adjustment User Settings & Control System MenusBlower Low On , Blower High On displays whether TemperaturesHeater Status ECO Contact , Blocked Inlet PS , Blocked Outlet PS , BlowerHeater Information Display SettingsRestore Factory Defaults Current FaultFault History Fault OccurrenceService Contact Information Service Contact InformationOperational Conditions For your informationStart UP Conditions Anode ROD Inspection Periodic maintenanceTemperature-Pressure Relief Valve Operation Venting System InspectionTo Flush the Water Heater Storage Tank ServiceTo drain the water heater storage tank Temperature-Pressure Relief Valve Test MaintenanceLeakage checkpoints Installation Checklist TroubleshootingYES no Sequence Of Operation Flow ChartFault And Alert Conditions Operational ProblemsDiagnostic Checks Resetting Control System Lock OutsAC Reversed Fault And Alert MessagesBlower Prover Failure Page Page Page Fill in Warranty and Keep for Future Reference Limited Warranty

100 Power Vent DV Series 120, 317443-000 specifications

The A.O. Smith 317443-000,100 Power Vent DV Series 120 is an advanced water heating solution designed to enhance efficiency and performance for residential applications. As part of A.O. Smith's renowned lineup, this model embodies the company's commitment to innovation and energy conservation.

One of the main features of the DV Series 120 is its power venting capability. This technology allows for flexible installation options, as it can vent vertically or horizontally, accommodating various home configurations. It utilizes a fan-assisted venting system, which efficiently expels exhaust gases, ensuring safe operation even in tight spaces.

The unit's energy efficiency is another standout characteristic. Equipped with a high-efficiency gas burner, the DV Series 120 optimizes fuel consumption, resulting in lower utility bills while providing reliable hot water when needed. Its impressive Energy Factor (EF) ratings make it an environmentally friendly choice, aligning with modern standards for green building practices.

Durability is also a significant focus of the A.O. Smith 317443-000,100 Power Vent model. Constructed with a glass-lined tank and a robust anode rod, this water heater is designed to resist corrosion and extend its lifespan. This construction enhances performance reliability while minimizing maintenance needs, making it a smart investment for homeowners.

Smart technologies are integrated into the DV Series 120, featuring an intelligent control system that provides various operational insights. The built-in diagnostic features allow homeowners to monitor performance and identify potential issues early, reducing the likelihood of unexpected failures. This control system can also enable more precise temperature management, enhancing both comfort and efficiency.

Safety is paramount in the design of the A.O. Smith 317443-000,100. The unit comes equipped with safety features such as a built-in flame rollout sensor and an automatic shut-off system to protect against potential hazards. These features ensure peace of mind for users, allowing them to confidently rely on their hot water supply.

In summary, the A.O. Smith 317443-000,100 Power Vent DV Series 120 stands out as a high-efficiency water heating solution, combining innovative venting technologies, durability, smart features, and safety mechanisms. This model is an ideal choice for homeowners seeking a reliable and efficient hot water system that meets modern energy standards.