A.O. Smith BTI 100 G, BTI 85 G manual Removing and replacing the control panel front cover

Page 17

2.3Removing and replacing the control panel front cover

Removing the cover (see figure 7)

1.Remove the screw at the top centre of the control panel.

2.Push the cover upwards until the hooks at the lower end clear the burner access opening and base tray.

3.Pull the lower end of the cover slightly forward.

4.Pull the cover down until the top edge is clear of the control panel and then remove.

Replacing the cover (see figure 7)

1.Place the top of the cover inside the rim of the control panel and push it up as far as possible.

2.Position the bottom hooks inside the burner access opening and over the rim of the base tray.

3.Push the cover downwards until the lower hooks engage and the top screw holes align.

4.Replace the screw in the top centre of the cover.

2.4Setting the gas pressure

The gas pressure has been set to the correct values at the factory.

Important: The following proce- dure must be followed when checking or setting the gas pressure:

1.Shut down the heater by switching off the mains current (switch off main switch);

2.Connect a manometer to the pressure test nipple to measure the burner pressure on the gas control.

3.Activate the heater and allow the burner to ignite;

4.Check the burner pressure. If necessary, reset it by means of the burner pressure adjusting screw. Turning it anti-clockwise reduces burner pressure. Turning it clockwise increases burner pressure;

5.Shut down the heater, remove the manometer and close the pressure nipple;

6.Restart the heater (test for soundness).

AOS 1130

Figur 7 taking off and mounting the control panel

17

Image 17
Contents BTI 100 G BTI 85 GPage Contents General Description of the appliance GeneralPage Control panel Technical safety equipmentGas control valve Operation of the storage water heater Combustion products discharge safety deviceNormal operation Ignition failureDimensions DimensionsTechnical information BTIAOS Unit BTI Technical dataData Naturel GAS G20 20 mbar Data Butane G30 30 mbarIonisation current Electrical connectionInstallation Installation instructionsFor domestic applications For non-domestic applicationsVented systems See figur Water circulation systemUnvented system See figur Flue system Gas connectionDraught diverter Electrical connectionFilling the water heater CommissioningPutting into operation Shut downRemoving and replacing the control panel front cover Setting the gas pressureRemoving the cover see figure Replacing the cover see figureMounting the inner door Temperature regulationConverting to another type of gas MaintenanceMagenesium anode Unit BTICondensation Inlet combinationGas smell 3 Use CommisioningFailure Possible Cause Corrective Action Fault overviewGuarantee of the tank Guarantee in generalConditions for installation and use Range of guaranteeClaims Appendix 1 Connection diagram BTI models Page Page 0308 253 R0