1.3.2 Technical data | device category: II2H3+ |
| |||
|
|
|
|
| |
DESCRIPTION |
| unit | BTI 85 | BTI 100 | |
|
|
|
| ||
DATA NATUREL GAS G20 - 20 mbar |
|
|
| ||
Nominal capacity |
| kW | 19.2 | 20.4 | |
Nominal load (gross) |
| kW | 25.1 | 26.7 | |
Supply | pressure |
| mbar | 20 | 20 |
Burner | pressure |
| mbar | 12.0 | 7.9 |
Gas consumption * |
| m3/h | 2.40 | 2.50 | |
Diameter main orifice |
| mm | 3.90 | 4.50 | |
Diameter pilot orifice |
| mm | 0.56 / 0.41 | 0.56 / 0.41 | |
Heating time ΔT= 45K |
| min | 46 | 58 | |
DATA BUTANE G30 - 30 mbar |
|
|
| ||
Nominal load (gross) |
| kW | 24.5 | 26.0 | |
Nominal capacity |
| kW | 19.2 | 20.4 | |
Supply | pressure |
| mbar | 30 | 30 |
Gas consumption * |
| kg/h | 1.8 | 1.9 | |
Diameter main orifice |
| mm | 2.30 | 2.35 | |
Diameter pilot orifice |
| mm | 0.23 | 0.23 | |
DATA PROPANE G31 - 37 mbar |
|
|
| ||
Nominal heat input (upper valvue) | kW | 22.9 | 24.9 | ||
Output |
|
| kW | 17.9 | 19.5 |
Inlet pressure |
| mbar | 37 | 37 | |
Gas consumption * |
| kg/h | 1.6 | 1.8 | |
Diameter main orifice |
| mm | 2.30 | 2.35 | |
Diameter pilot orifice |
| mm | 0.23 | 0.23 | |
GENERAL |
|
|
|
| |
Storage | capacity |
| litres | 278 | 372 |
Water connections** |
| - | |||
Gas connection |
| - | Rp1/ | Rp1/ | |
|
|
|
| 2 | 2 |
Drain valve |
| - | 3/ | 3/ | |
|
|
|
| 4 | 4 |
Anode |
|
| - | 3/ | 3/ |
|
|
|
| 4 | 4 |
T&P plug |
| - | 3/ | 3/ | |
|
|
|
| 4 | 4 |
Maximum operating pressure |
| bar | 8 | 8 | |
Empty weight |
| kg | 122 | 149 |
*Gas consumption at 1013,25 mbar and 15 °C
**For a leak proof sealed connection European coupling pieces can be used on the NPT connection nipples with a pipe thread of ISO 228/1