1.3.2 Technical data

device category: II2H3+

 

 

 

 

 

 

DESCRIPTION

 

unit

BTI 85

BTI 100

 

 

 

 

DATA NATUREL GAS G20 - 20 mbar

 

 

 

Nominal capacity

 

kW

19.2

20.4

Nominal load (gross)

 

kW

25.1

26.7

Supply

pressure

 

mbar

20

20

Burner

pressure

 

mbar

12.0

7.9

Gas consumption *

 

m3/h

2.40

2.50

Diameter main orifice

 

mm

3.90

4.50

Diameter pilot orifice

 

mm

0.56 / 0.41

0.56 / 0.41

Heating time ΔT= 45K

 

min

46

58

DATA BUTANE G30 - 30 mbar

 

 

 

Nominal load (gross)

 

kW

24.5

26.0

Nominal capacity

 

kW

19.2

20.4

Supply

pressure

 

mbar

30

30

Gas consumption *

 

kg/h

1.8

1.9

Diameter main orifice

 

mm

2.30

2.35

Diameter pilot orifice

 

mm

0.23

0.23

DATA PROPANE G31 - 37 mbar

 

 

 

Nominal heat input (upper valvue)

kW

22.9

24.9

Output

 

 

kW

17.9

19.5

Inlet pressure

 

mbar

37

37

Gas consumption *

 

kg/h

1.6

1.8

Diameter main orifice

 

mm

2.30

2.35

Diameter pilot orifice

 

mm

0.23

0.23

GENERAL

 

 

 

 

Storage

capacity

 

litres

278

372

Water connections**

 

-

1-11.5 NPT

11/4-11.5 NPT

Gas connection

 

-

Rp1/

Rp1/

 

 

 

 

2

2

Drain valve

 

-

3/ "-14NPT

3/ "-14NPT

 

 

 

 

4

4

Anode

 

 

-

3/ "-14NPT

3/ "-14NPT

 

 

 

 

4

4

T&P plug

 

-

3/ "-14NPT

3/ "-14NPT

 

 

 

 

4

4

Maximum operating pressure

 

bar

8

8

Empty weight

 

kg

122

149

*Gas consumption at 1013,25 mbar and 15 °C

**For a leak proof sealed connection European coupling pieces can be used on the NPT connection nipples with a pipe thread of ISO 228/1

10

Image 10
Contents BTI 85 G BTI 100 GPage Contents General General Description of the appliancePage Gas control valve Technical safety equipmentControl panel Normal operation Combustion products discharge safety deviceOperation of the storage water heater Ignition failureTechnical information DimensionsDimensions BTIAOS Data Naturel GAS G20 20 mbar Technical dataUnit BTI Data Butane G30 30 mbarElectrical connection Ionisation currentFor domestic applications Installation instructionsInstallation For non-domestic applicationsWater circulation system Vented systems See figurUnvented system See figur Draught diverter Gas connectionFlue system Electrical connectionPutting into operation CommissioningFilling the water heater Shut downRemoving the cover see figure Setting the gas pressureRemoving and replacing the control panel front cover Replacing the cover see figureTemperature regulation Mounting the inner doorMagenesium anode MaintenanceConverting to another type of gas Unit BTIGas smell Inlet combinationCondensation Commisioning 3 UseFault overview Failure Possible Cause Corrective ActionConditions for installation and use Guarantee in generalGuarantee of the tank Range of guaranteeClaims Appendix 1 Connection diagram BTI models Page Page 0308 253 R0