A.O. Smith BTI 85 G, BTI 100 G manual Mounting the inner door, Temperature regulation

Page 18

2.5Mounting the inner door

Mode of operation: (see figur 8).

1.Place the clips in the position on the inner door so the door can fullty stick into the opening.

2.Lift the door up and rotate it over the burner into position.

3.Pull the inner door against the inside of the skirt ring.

4.Rotate the clips into postion with a tool.

Figur 8 Removing and replacing the inner door.

1)Burner bracket

2)Inner door

3)Clip

4)Mainburner

2.6Temperature regulation

The appliance is under water supply pressure (maximum 8 bar). The amount of cold water that is added is equal to the amount of hot water used. The gas control block automatically regulates the gas supply. The main burner will ignite as soon as a reduction in water temperature is sended by the thermostat. The main burner will shut down as soon as the preset temperature is achieved.

At high water temperatures there is more scale buildup in the appliance. It is for this reason that it is recommended to place the temperature control knob in position of

60 °C as the accumulation of scale will be reduced.

5)Skirt ring

6)Outer casting

7)Base tray

18

Image 18
Contents BTI 85 G BTI 100 GPage Contents General General Description of the appliancePage Technical safety equipment Gas control valveControl panel Normal operation Combustion products discharge safety deviceOperation of the storage water heater Ignition failureTechnical information DimensionsDimensions BTIAOS Data Naturel GAS G20 20 mbar Technical dataUnit BTI Data Butane G30 30 mbarElectrical connection Ionisation currentFor domestic applications Installation instructionsInstallation For non-domestic applicationsWater circulation system Vented systems See figurUnvented system See figur Draught diverter Gas connectionFlue system Electrical connectionPutting into operation CommissioningFilling the water heater Shut downRemoving the cover see figure Setting the gas pressureRemoving and replacing the control panel front cover Replacing the cover see figureTemperature regulation Mounting the inner doorMagenesium anode MaintenanceConverting to another type of gas Unit BTIInlet combination Gas smellCondensation Commisioning 3 UseFault overview Failure Possible Cause Corrective ActionConditions for installation and use Guarantee in generalGuarantee of the tank Range of guaranteeClaims Appendix 1 Connection diagram BTI models Page Page 0308 253 R0