1.2Technical safety equipment

1.2.1 Gas control valve

The water heater is equipped with a gas control wich regulates the flow of gas to the burner. The gas block is equipped with a safety valve, gas valve and burner control (on a standard natural gas setting). To ensure improved ignition the gas control valve opening mechanism is fitted with a delay (softlite).

The gas control block is suitable for gasses from the first, second and third gas family. The maximum inlet pressure is 60 mbar.

Figur 2 - Top view of the heater

A ) Hot water outlet

B) Cold water inlet

1)Electrical connection

2)ON/OFF switch

3)Ignition controller reset button

4)Control thermostat knob

5)Safety thermostat reset button

The automatic incandescent ignition (hot surface) ensures that the burner ignites as soon as there is a demand for heat.

1.2.2Control panel

Temperature control for the water heater is housed in the control panel (See figur 2). For safety purposes, heaters are always fitted with two thermostats: a control thermostat is adjustable between 40 °C and 80 °C and a safety thermostat 90 °C. The control panel is fitted with an ON/OFF switch (I/0). At setting ”I”, the gas control is activated on the basis of heat demand from the control thermostat. At setting ”0” the heater is switched off.

6

Image 6
Contents BTI 85 G BTI 100 GPage Contents General General Description of the appliancePage Technical safety equipment Gas control valveControl panel Normal operation Combustion products discharge safety deviceOperation of the storage water heater Ignition failureTechnical information DimensionsDimensions BTIAOS Data Naturel GAS G20 20 mbar Technical dataUnit BTI Data Butane G30 30 mbarElectrical connection Ionisation currentFor domestic applications Installation instructionsInstallation For non-domestic applicationsWater circulation system Vented systems See figurUnvented system See figur Draught diverter Gas connectionFlue system Electrical connectionPutting into operation CommissioningFilling the water heater Shut downRemoving the cover see figure Setting the gas pressureRemoving and replacing the control panel front cover Replacing the cover see figureTemperature regulation Mounting the inner doorMagenesium anode MaintenanceConverting to another type of gas Unit BTIInlet combination Gas smellCondensation Commisioning 3 UseFault overview Failure Possible Cause Corrective ActionConditions for installation and use Guarantee in generalGuarantee of the tank Range of guaranteeClaims Appendix 1 Connection diagram BTI models Page Page 0308 253 R0