Table 10.1 General errors (Sheet 2 of 3)
is
Symptom | Cause | Solution | Remark | |
|
|
|
| |
Display is off | Appliance is turned off. |
| ||
|
|
|
|
|
| No electric power | 1. | Check whether the mains switch is ON. | See appendix ’A.2 Electrical diagram BFC’. |
| present | 2. | Check that there is power to the mains switch. | If the error cannot be rectified, contact your installer. |
|
|
| ||
|
| 3. | Check whether the ON/OFF switch of the ThermoControl is ON |
|
|
|
| (position I). |
|
|
| 4. | Check whether there is power to the electrical connection |
|
|
|
| block. |
|
|
| 5. | The voltage measured must be 230 VAC |
|
|
|
|
| |
| Defective fuse(s) | Replace fuse(s) | To replace the fuses you must contact your installer. | |
|
|
|
| |
Water leakage | Leakage from one of | Tighten the threaded connection. | If the leak persists, consult your installer. | |
| the water connections |
|
|
|
| (threaded). |
|
|
|
|
|
|
| |
| Condensation water | Check that the condensation water discharge is working properly. |
| |
| leakage | Rectify if necessary. |
| |
|
|
|
| |
| Leakage from another | Trace the leak. |
| |
| nearby water |
|
|
|
| appliance or pipe |
|
|
|
| segment. |
|
|
|
|
|
|
| |
| Leakage from the | Consult the supplier and/or manufacturer. |
| |
| appliance’s tank. |
|
|
|
|
|
|
|
|
Release R.1.3 UK | 71 |