ELECTRICAL WARNING
eTo reduce the risk of electrical shock, this equipment has a grounding type Plug that has a third (grounding) Pin. This Plug will only fit into a grounding type outlet. If the Plug does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do Not change the Plug in any way.The door Opener must be properly grounded to prevent personal injury and damage to the components.
The electrical power to the door Opener Must Be removed when the Motor Cover is removed. Electrical power must remain off while making electrical connections.
ACheck building codes:
•If building code requires Opener be permanently wired to building, have a licensed electrician perform step B.
•If you are not installing permanent wiring, go to step C.
Instructions for licensed electrician - connecting power with permanent wiring (Figure 33):
•Remove power from circuit.
•Remove Motor Cover.
•Remove and discard Power Cord.
-Cut off Power Cord inside Power Head as near Strain Relief as possible.
-Remove
-Dispose of Plug, Strain Relief, and Power Cord.
•Install required entrance bushing.
•Connect permanent wiring to Power Head Wires.
-White supply line to Opener White Wire.
-Black supply line to Opener Black Wire.
-Ground to Opener Green Wire.
-Replace Motor Cover.
NOTE
eUse only Underwriters Laboratories, Inc. (U.L.) recognized wire nuts.
The Circuit Boards are light sensitive. Ensure the Motor Cover is installed before energizing
the Opener.
-Restore Power to circuit.
CConnecting Power with Plug:
•Plug Opener into a grounded outlet as stated in previous electrical warning.
DPerform
•Check if
•If Red LED is blinking twice, adjust Sensor Brackets as needed to make Red LED glow continuously. (Refer to page 26.)
Knockout
Cut
Wires
here
Two
tabs slide out
I
Four screws hold
Motor Cover