ITEM

DESCRIPTION

 

 

QTY

PART NUMBER

1

SUPPORT PLATE

 

 

1

N P 1 4 0 0 5 5 - B R S

 

 

 

 

 

 

 

2

DIAPHRAGM

 

 

 

1

N P 1 7 0 0 3 1 - T H Y

 

 

 

 

 

3

REAGENT HEAD PVDF

 

1

N P 1 6 0 0 7 7 - P V D

 

 

 

 

3

REAGENT HEAD PVC (obsolete)

1

N P 1 6 0 0 5 5 - P V C

 

 

 

 

 

3

REAGENT HEAD 316

 

1

N P 1 6 0 0 5 5 - 3 1 6

 

 

 

 

 

 

 

4

BOLT

 

 

 

4

N P 9 9 0 4 3 6 - 1 8 8

 

 

 

 

 

 

5

FLT WASHER

 

 

4

N P 9 9 1 0 1 8 - 1 8 8

 

 

 

 

 

7

VLV/CONN ISO 7-1 PVDF

DISCHARGE

1

N P 3 2 B V C 8 - P V D

 

 

 

 

 

7

VLV/CONN ISO 7-1 316

DISCHARGE

1

N P 3 2 B A A 8 - 3 1 6

 

 

 

 

 

7

VLV/CONN ISO 7-1 PVC

DISCHARGE (obs)

1

N P 3 2 B V C 8 - P V C

 

 

 

 

 

 

7

VLV/CONN NPT

PVDF

DISCHARGE

1

N P 3 2 P V D 8 - P V D

 

 

 

 

 

 

7

VLV/CONN NPT

316

DISCHARGE

1

N P 3 2 P A A 8 - 3 1 6

 

 

 

 

 

 

7

VLV/CONN NPT

PVC

DISCHARGE (obs)

1

N P 3 2 P V C 8 - P V C

 

 

 

 

 

8

VLV/CONN ISO 7-1 PVDF

SUCTION

1

N P 3 1 B V C 8 - P V D

 

 

 

 

 

8

VLV/CONN ISO 7-1 316

SUCTION

1

N P 3 1 B A A 8 - 3 1 6

 

 

 

 

 

8

VLV/CONN ISO 7-1 PVC

SUCTION (obs)

1

N P 3 1 B V C 8 - P V C

 

 

 

 

 

 

8

VLV/CONN NPT

PVDF

SUCTION

1

N P 3 1 P V D 8 - P V D

 

 

 

 

 

 

8

VLV/CONN NPT

316

SUCT

1

N P 3 1 P A A 8 - 3 1 6

 

 

 

 

 

 

8

VLV/CONN NPT

PVC

SUCT (obs)

1

N P 3 1 P V C 8 - P V C

 

 

 

 

 

 

9

RETURN SPRING

 

 

1

N P 4 3 0 0 3 4 - 0 0 0

 

 

 

 

 

 

10

BOTTOM COVER

 

 

1

N P 2 5 0 0 8 5 - 0 0 0

 

 

 

 

 

11

BOTTOM COVER SCREW

 

4

N P 9 9 2 2 1 6 - S T L

 

 

 

 

 

12

STRADLE ASSEMBLY

 

1

N P 4 1 0 0 6 7 - 0 0 0

 

 

 

 

 

 

 

13

BEARING

 

 

 

1

N P 4 0 0 0 3 8 - 0 0 0

 

 

 

 

 

 

 

14

ECCENTRIC

 

 

 

1

N P 0 7 0 0 2 3 - 0 0 0

 

 

 

 

 

 

 

15

BEARING

 

 

 

1

N P 4 0 0 0 4 2 - 0 0 0

 

 

 

 

 

16

DC4 SPOOL ADAPTOR

 

1

N P 1 4 0 0 6 8 - A L U

 

 

 

 

 

 

17

WORM

8:1

 

1

W 2 0 8 7 6 4 - 0 0 8

 

 

 

 

 

 

17

WORM

10:1

 

1

W 2 0 8 7 6 4 - 0 1 0

 

 

 

 

 

 

17

WORM

15:1

 

1

W 2 0 8 7 6 4 - 0 1 5

 

 

 

 

 

17

WORM

30:1 (obsolete)

1

W 2 0 8 7 6 4 - 0 3 0

 

 

 

 

 

 

 

18

SCREW

 

 

 

1

W 7 7 0 0 1 0 - 0 0 0

 

 

 

 

 

 

 

19

GASKET

 

 

 

1

N P 4 6 0 0 4 5 - 0 0 0

 

 

 

 

 

 

 

20

SIDE COVER

 

 

 

1

N P 2 5 0 0 6 0 - S T L

 

 

 

 

 

 

 

21

BOLT

 

 

 

4

N P 9 9 0 4 1 4 - 1 8 8

 

 

 

 

 

 

 

22

GEAR

8:1

 

 

1

W 2 0 8 7 6 5 - 0 0 8

 

 

 

 

 

 

 

22

GEAR

10:1

 

 

1

W 2 0 8 7 6 5 - 0 1 0

 

 

 

 

 

 

 

22

GEAR

15:1

 

 

1

W 2 0 8 7 6 5 - 0 1 5

 

 

 

 

 

 

22

GEAR

30:1 (obsolete)

 

1

W 2 0 8 7 6 5 - 0 3 0

 

 

 

 

 

23

THRUST WASHER

 

1

N P 4 7 0 0 3 0 - 0 0 0

 

 

 

 

 

24

ECCENTRIC SHAFT

 

1

N P 4 1 0 0 5 5 - 0 0 0

 

 

 

 

 

 

 

25

BEARING

 

 

 

2

N P 4 0 0 0 4 0 - 0 0 0

 

 

 

 

 

26

STRK ADJ ASSEMBLY

 

1

N P 2 6 0 0 1 3 - 0 0 0

 

 

 

 

 

 

 

27

KNOB

 

 

 

1

N P 2 6 0 0 0 1 - G P C

 

 

 

 

 

 

28

KNOB COVER

 

 

1

N P 2 5 0 0 6 1 - 0 0 0

 

 

 

 

 

 

 

29

SCREW

 

 

 

1

W 7 7 1 0 0 1 - 0 1 0

 

 

 

 

 

 

 

35

Image 39
Contents Models DC2, 3, 4, 5, Installation, Operation Maintenance InstructionSafety Considerations Pulsafeeder Factory Service PolicyTable of Contents 14.1 Principles Of Operation IntroductionReagent Head Assembly Control AssemblyGear Ratio Assembly Location InstallationEquipment Inspection StoragePiping System Discharge Pressure Requirements Suction Pressure RequirementsOutput Adjustment Equipment StartupFastener Inspection Process flow Priming the Reagent HeadSample flow calibration curve CalibrationLubrication MaintenanceWet end components Wet End Removal, Inspection, & ReinstallationDiaphragm Removal & Reinstallation General Description Check ValvesCheck valves, DC3 and DC Check Valve Removal & Reinstallation, Cartridge type DC5 and 6 check valves, metal construction Gearset Removal Motor Removal & ReinstallationGearset components Gearset Replacement Replacement Parts KOPkit ProgramOrdering KOPkits or Parts Pump Model Wetted Material Connection Type KOPkit number KOPkit numbers by modelNPT Model Number IdentificationPvdf Wet End Materials ReferenceDifficulty Probable Cause Remedy Pump does not start TroubleshootingDifficulty Probable Cause Remedy Noisy gearing Pressure Relief Valves Piping AccessoriesLetters reference dimensional table on next Dimensional DrawingDC5 PP/PVDF Parts diagram, DC2 Parts Diagrams and Parts ListsDescription QTY Part Number Bill of Materials, DC2Name TAG Bill of Materials, DC3 4 7 0 0 4 1 S T L This page intentionally left Blank Parts Diagram, DC4, 5, Bill of Materials, DC4 DC4/5 Gearbox Bill of Materials, DC5 Tiebar Bill of Materials, DC6 DC4/5/6 Gearbox Page Standard Pump Operations

DC5, DC6, DC3, DC4, DC2 specifications

Honeywell has long been a leader in the development of advanced technological solutions across various industries, and its line of DC models—DC2, DC3, DC4, DC5, and DC6—showcases that commitment to innovation. These devices are designed to enhance efficiency, safety, and connectivity across diverse applications, primarily in the realms of industrial automation, aerospace, and building management systems.

The Honeywell DC2 unit stands out with its compact design, making it ideal for environments where space is limited. It features a rugged build quality that can withstand harsh conditions, and it is equipped with advanced sensing technologies. This model is often preferred for its ease of integration with existing systems, allowing users to leverage advanced analytics capabilities without significant infrastructure changes.

The DC3 takes connectivity a step further, providing enhanced networking capabilities that facilitate real-time data monitoring and control. Its user-friendly interface allows operators to interact effortlessly with the system, ensuring that critical information is easily accessible. This model is particularly valued in manufacturing environments for its support of IoT technologies, enabling smart factory transformations.

Building upon these features, the DC4 model introduces machine learning algorithms that predict maintenance needs, thereby minimizing downtime and maximizing productivity. This proactive approach to maintenance is essential in today’s fast-paced industrial landscape. The DC4 is ideally suited for logistics and supply chain applications, where every second counts, and operational efficiency is paramount.

The DC5 model features advanced cybersecurity measures to protect sensitive data against evolving threats. With end-to-end encryption and secure access protocols, users can be assured that their operations remain safe from cyberattacks. This is particularly vital for industries that handle critical infrastructure, where breaches could lead to catastrophic consequences.

Lastly, the DC6 model epitomizes versatility with its multi-functionality. It supports various applications, from environmental monitoring in smart buildings to advanced control systems in aerospace. Its ability to seamlessly adapt to different environments and use cases positions it as a go-to solution for enterprises aiming for digital transformation.

In summary, Honeywell’s DC series models—DC2, DC3, DC4, DC5, and DC6—each brings unique features and cutting-edge technologies. They offer powerful tools for enhancing operational efficiency, safety, and connectivity across a multitude of industries. Whether through compact design, enhanced connectivity, predictive maintenance capabilities, robust cybersecurity measures, or versatile applications, these models underscore Honeywell's commitment to driving innovation and excellence in industrial solutions.