Wiring the Power and Control Cables
Power and control cables are routed through the bottom of the connection box through two strain relief bushings.
Green ground wire connects here
Power cable entry | Control cable entry |
Figure 4: Connection box – cable routing
Wire the connection box according to Figure 5. Connections are described in detail in Table 1 on page 11.
I24VAC/DC S.B. -
JLL - Total lack of oil
Voltage selector switch SW1:
115 VAC / 24 V AC/DC
J
J
PULSE - Drip indication
O.K. - Sufficient lubrication
Power cable 115 VAC or
24 VAC/VDC
Control cable
Note: The pump can be optionally wired to shut down when the O.K. relay contacts open.
Figure 5: Connection box – electrical terminals: 115 VAC unit shown
1.Set the power switch SW1 located just below the transformer, for line power (115 VAC or 220 VAC) or 24 V AC/DC according to your requirements. See Figure 5.