Section 5: Maintenance and Troubleshooting

Table 4: Routine Maintenance

Task

Check for oil leaks

Oil filter change (the oil filter used can be an automotive fuel filter with ¼" fittings)

Check for normal operation

The displayed drip rate is equal to the Normal (pump on) mode drip rate setting, within a -1, +2 digit tolerance

Frequency

Monthly

Every six months

Weekly

Table 5: Troubleshooting

Problem

 

Possible Cause

 

Solution

The display and LEDs are not lit.

 

The unit is not powered.

 

Check power in the connection

 

 

 

 

box.

An unusual result appears on the

 

Changing the mode toggle

 

Ignore.

display

 

switch (item 8 in Figure 6 on

 

 

 

 

page 13).

 

 

You want to quickly stabilize the

 

You just refilled the oil tank.

 

With the Mode toggle switch

Dripmaster for a new drip rate

 

 

 

(item 2 in Figure 6 on page 13)

 

 

 

 

in automatic (AUTO), hold

 

 

 

 

down the Close push button

 

 

 

 

momentarily to slow down the

 

 

 

 

drip rate.

 

 

You just increased the drip rate

 

With the Mode toggle switch in

 

 

setting in the Normal (pump on)

 

 

 

 

position AUTO, hold down the

 

 

mode.

 

 

 

 

Open push button momentarily

 

 

 

 

 

 

 

 

to speed up the drip rate.

A suspected fault has occurred in

 

Circuit failure

 

Set the Mode switch to MAN,

the system; the drip rate is much

 

 

 

and set the drip rate manually

higher or lower than expected.

 

 

 

using the Open and Close

 

 

 

 

push buttons. See Figure 6.

23

Image 23
Contents Patent No ,996,739 & other countries Dripmaster EDD-4CRevision Section Revision HistoryContents List of Tables List of FiguresOverview IntroductionEnd of section Well Site Requirements InstallationGeneral Installation requirements Mounting the Dripmaster Installation KitConnection box cable routing Wiring the Power and Control Cables24VAC/DC S.B. Pre-lube Connection box-power and control linesPump On/Off conditions Setting the Drip RateOperation Controls and IndicatorsOpen Name Control or Number Indicator Automatic Control Setting Normal pump on Mode Drip RatesManual Control Pre-lube pump off ModeDripmaster EDD-4C Needle Valve Assembly Resetting the DripmasterHourstime Elapsed Theory of OperationControl Circuitry Overflow/vent hose Search FeaturePush-Down and Push-up Features Frequency Maintenance and TroubleshootingRoutine Maintenance Task Troubleshooting Problem Possible Cause SolutionProblem Possible Cause Solution Dripmaster EDD-4C specifications SpecificationsDripmaster dimensions Overall DimensionsRepair procedure Dripmaster Service PolicyInstallation Return Instructions Product within the Warranty PeriodProduct Out-of-Warranty Period Shipping Terms & Conditions on reverse