Hoffman Media EDD-4C manual Problem Possible Cause Solution

Page 24

Problem

 

Possible Cause

 

Solution

 

The OIL LED is on.

 

Oil tank is empty

 

Refill the oil tank

 

 

A shut-off valve at the outlet of

 

Open the shut-off valve

 

 

the oil tank might be closed

 

Change the oil filter, or clean out

 

 

Oil flow from the oil tank may be

 

 

 

 

any obstructions in the pipe

 

 

obstructed; the oil filter may be

 

between the oil tank and the

 

 

clogged

 

Dripmaster inlet

 

 

Oil blockage between the

 

Clean out any obstructions in

 

 

Dripmaster outlet pipe and the

 

the pipe between the

 

 

line-shaft—excessive oil briefly

 

Dripmaster outlet and the line-

 

 

flows from a built-in overflow

 

shaft.

 

 

hose

 

 

 

 

 

 

Note: Reset the system after fixing

 

 

 

 

 

 

 

 

 

 

the problem. See Resetting

 

 

 

 

 

the Dripmaster on page 18.

 

 

 

 

 

After restoration, the

 

 

 

 

 

counter displays 00, and the

 

 

 

 

 

drip search function causes

 

 

 

 

 

the motor to open the

 

 

 

 

 

needle valve until drops are

 

 

 

 

 

detected, after which normal

 

 

 

 

 

stabilization occurs.

 

24

Image 24
Contents Dripmaster EDD-4C Patent No ,996,739 & other countriesRevision History Revision SectionContents List of Figures List of TablesIntroduction OverviewEnd of section Installation GeneralWell Site Requirements Installation requirements Installation Kit Mounting the DripmasterWiring the Power and Control Cables Connection box cable routingConnection box-power and control lines 24VAC/DC S.B. Pre-lubeSetting the Drip Rate Pump On/Off conditionsControls and Indicators OperationOpen Name Control or Number Indicator Setting Normal pump on Mode Drip Rates Automatic ControlPre-lube pump off Mode Manual ControlResetting the Dripmaster Dripmaster EDD-4C Needle Valve AssemblyTheory of Operation Hourstime ElapsedControl Circuitry Search Feature Overflow/vent hosePush-Down and Push-up Features Maintenance and Troubleshooting Routine Maintenance TaskTroubleshooting Problem Possible Cause Solution FrequencyProblem Possible Cause Solution Specifications Dripmaster EDD-4C specificationsOverall Dimensions Dripmaster dimensionsDripmaster Service Policy InstallationRepair procedure Product within the Warranty Period Product Out-of-Warranty PeriodReturn Instructions Terms & Conditions on reverse Shipping