Hoffman Media EDD-4C manual Push-Down and Push-up Features

Page 22

lower limit and the OIL LED lights continuously. The LL relay outlet contact closes, transmitting a total lack of oil condition. At this stage, there is no vertical line-shaft lubrication which means that either the oil tank is empty or there is an oil flow blockage between the oil tank outlet and the Dripmaster inlet.

In the case of oil flow blockage in the Dripmaster outlet pipe, excess oil briefly flows from a built-in overflow hose (see Figure 10 above). Also, the OIL LED turns on, and oil flow is cut off by the closure of the needle valve. After taking corrective measures, you must reset the system. See "Resetting the Dripmaster" on page 18.

The internal solenoid provides instantaneous on/off control of oil flow. Whenever the system power (115 VAC, 220 VAC, or 24 V AC/DC) is on, the energized solenoid allows oil flow. Oil flow stops when the system power ceases. The oil flow can be manually opened or closed via the manual oil flow switch (Figure 10).

Push-Down and Push-up Features

In order to enhance the response time of the system whenever the drip rate exceeds 80 dpm, an automatic push-down mechanism is engaged. This is achieved by continuously closing the valve for a number of seconds. Excessive drip rates may occur when filling an empty oil tank, or when the Dripmaster has finished scanning.

Similarly, an automatic push-up mechanism accelerates the stabilization of the system whenever the Dripmaster is transferred from the Pre-lube (pump off) mode to the Normal (pump on) mode. This mode change occurs when the 24 V AC/DC is removed from the S.B. terminals in the connection box.

22

Image 22
Contents Dripmaster EDD-4C Patent No ,996,739 & other countriesRevision History Revision SectionContents List of Figures List of TablesIntroduction OverviewEnd of section General InstallationWell Site Requirements Installation requirements Installation Kit Mounting the DripmasterWiring the Power and Control Cables Connection box cable routingConnection box-power and control lines 24VAC/DC S.B. Pre-lubeSetting the Drip Rate Pump On/Off conditionsControls and Indicators OperationOpen Name Control or Number Indicator Setting Normal pump on Mode Drip Rates Automatic ControlPre-lube pump off Mode Manual ControlResetting the Dripmaster Dripmaster EDD-4C Needle Valve AssemblyTheory of Operation Hourstime ElapsedControl Circuitry Search Feature Overflow/vent hosePush-Down and Push-up Features Troubleshooting Problem Possible Cause Solution Maintenance and TroubleshootingRoutine Maintenance Task FrequencyProblem Possible Cause Solution Specifications Dripmaster EDD-4C specificationsOverall Dimensions Dripmaster dimensionsInstallation Dripmaster Service PolicyRepair procedure Product Out-of-Warranty Period Product within the Warranty PeriodReturn Instructions Terms & Conditions on reverse Shipping