Hoffman Media EDD-4C manual Setting the Drip Rate, Pump On/Off conditions

Page 12

Table 2: Pump On/Off conditions

Status

OK LED on

OK LED off

Pump on

Drip rate greater than 15 dpm

Drip rate less than 15 dpm

 

O.K. relay contacts are closed

Total lack of oil (OIL LED on)

 

 

O.K. relay contacts are open

 

 

 

Pump off

Drip rate is equal to or greater than 2 dpm

Total lack of oil (OIL LED on)

 

O.K. relay contacts are closed

O.K. relay contacts are open

 

 

 

6.Connect an external time-delay relay of approximately four minutes to the O.K. output. This is necessary to extend the time needed for an OK indication during the transition from the pump- off state to the pump-on state.

7.Connect the oil filter (supplied) to the oil tank (Figure 2).

Important: The oil filter is essential as it prevents blockage in the needle valve.

8.Connect the Dripmaster oil outlet (Figure 7 on page 18, and Figure 2) to the well shaft inlet by means of flexible ¼-inch copper tubing.

Setting the Drip Rate

1.Set the dip switch settings for the Normal (pump on) mode using the drip rate setting toggle switches. (see Setting Normal (pump on) Mode on page 16).

Note: There are 50 drops per 1 cc, and there are 3785.4 cc per gallon.

2. Replace both covers and tighten the eight cover screws so that the unit is watertight.

12

Image 12
Contents Dripmaster EDD-4C Patent No ,996,739 & other countriesRevision History Revision SectionContents List of Figures List of TablesIntroduction OverviewEnd of section Installation GeneralWell Site Requirements Installation requirements Installation Kit Mounting the DripmasterWiring the Power and Control Cables Connection box cable routingConnection box-power and control lines 24VAC/DC S.B. Pre-lubeSetting the Drip Rate Pump On/Off conditionsControls and Indicators OperationOpen Name Control or Number Indicator Setting Normal pump on Mode Drip Rates Automatic ControlPre-lube pump off Mode Manual ControlResetting the Dripmaster Dripmaster EDD-4C Needle Valve AssemblyTheory of Operation Hourstime ElapsedControl Circuitry Search Feature Overflow/vent hosePush-Down and Push-up Features Maintenance and Troubleshooting Routine Maintenance TaskTroubleshooting Problem Possible Cause Solution FrequencyProblem Possible Cause Solution Specifications Dripmaster EDD-4C specificationsOverall Dimensions Dripmaster dimensionsDripmaster Service Policy InstallationRepair procedure Product within the Warranty Period Product Out-of-Warranty PeriodReturn Instructions Terms & Conditions on reverse Shipping