Maintenance and care

Replace light bulb

1.Unplug cleaner from electrical outlet.

2.Remove detachable canister and recline handle of vacuum.

3.Using a screwdriver, remove the one screw as shown and lift off the lens.

4.Remove the bulb from the socket by grasping bulb and pulling straight out. Install the new bulb by pushing it gently into the socket until the bulb snaps into place.

5.Reposition lens and secure with the one screw.

TurboBrush maintenance

The TurboBrush should be checked regularly for clogs or debris wrapping around the brush roll.

1. Unplug vacuum from electrical outlet.

2.If a clog is present or debris is visible, unscrew the two screws on the back of the TurboBrush to remove the faceplate and clear any obstructions.

3.To clean debris from the brush roll, remove the screw located on the belt cover. Lift the belt cover. Remove the brush roll from the drive belt and clean debris.

4.Reposition the drive belt on the brush roll. Place ends of brush roll in slots on sides as shown. Reposition belt cover and secure with shorter screw. Reposition faceplate and secure with two longer screws.

WARNING:

To reduce the risk of electric shock, turn Power Switch OFF and disconnect polarized plug from electrical outlet before performing maintenance or troubleshooting checks.

3.4.

2.

w w w . b i s s e l l . c a

1 - 8 0 0 - 2 6 3 - 2 5 3 5

13

Image 13 Contents
E R ’ S G U I D E WarrantyThank you for buying a Bissell Lift-OffMultiCyclonic vacuum Important Safety Instructions Product view Assembly How to use this guideAttach handle to vacuum Attach vacuum hose and toolsOperation Power switch/brush switchHandle position Pet TurboBrush snaps on to the holderSpecial tools Power height adjustmentPlace handle in upright position Shoulder Strap select models only Length of the strap may be adjusted as required for comfortTransporting Cleaner Power cord storageTurn vacuum cleaner off O Loop power cord around cord wraps on side of the canisterEmpty dirt container Maintenance and careReplace the Hepa media post-motor filter every six months Empty dirt into garbage containerUnplug the cleaner from electrical outlet Cleaning the pre-motor and post-motor filterUnplug the vacuum from electrical outlet Clean debris from the motor pulley and drive belt areas Unplug cleaner from electrical outletPulley Replace light bulb TurboBrush maintenanceReposition lens and secure with the one screw Unplug vacuum from electrical outletCleaning clogs Thermal protector Turn the cleaner OFF O and unplug from electrical outletRefer to the Clearing Clogs section Vacuum cleaner won’t run TroubleshootingVacuum cleaner is difficult to push Authorized service representative Visible dirt escaping from cleanerPossible causes Remedies M. 10 p.m. ET Bissell consumer serviceStyle SaturdayLimited Three Year Warranty WarrantyIf your Bissell product should require service