GE GNULQ, GXULQ Parts List, Install Compression Fittings, Final Check, Install the Batteries

Page 4

Installation Instructions

7 INSTALL COMPRESSION FITTINGS

ATake the remaining section of tubing, slide the compression hex nut and 3/8ferrule (tapered end away from the compression nut) onto the tubing, and put in the tube insert.

Shut-Off Valve Tubing Insert Ferrule

Hex Nut

Tubing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BFasten the assembly onto the cold water supply valve. Do not overtighten.

Shut-Off Valve Tubing Insert Ferrule Hex Nut

Tubing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Overtightening will cause the tubing to separate from the fitting.

NOTE: For shut-off valves with 1/2or 7/16compression fittings, please use appropriate adapters provided in the kit.

CConnect the other end to the inlet side as indicated by the arrow on the filter head/bracket.

9 FINAL CHECK

AInsert the filter into the filter head/bracket. Turn the filter 1/4 turn to the right until it stops. The top surface of the filter will become flush with the bottom of the filter head/bracket when it is fully installed.

BSlowly turn on the water supply.

CCheck the entire system for leaks. If there are leaks, refer back to the Cut the Tubing section to reinsert the tubing.

DIf leaking from fittings, shut off water pressure and tighten or reseal fittings. If leaking from the filter, tighten the filter.

EAfter installation, let water run for approximately 5 minutes to flush the filter and to remove air.

NOTE: It is normal for there to be air in the system causing bubbles in the water.

PARTS LIST

003

002

8

INSTALL THE BATTERIES

A

B

Insert coin or screwdriver in the slot between the timer cap and base.

Gently pry open and separate the timer base from the cap. Install or change 2 new AAA batteries. After having the batteries in place, line up the base and cap and snap them back together.

Blue Reset Button

Timer

Cap

2 AAA

Batteries

Timer

Base

NOTE: Timer

appearance may vary.

001

004

Ref. No.

Part No.

Part Description

 

001

GXULQR

Replacement Filter Cartridge

1

002

WS19X10024

Filter Head/Bracket

1

003

GXULQ-KIT

Kit

1

004

GXULQ-TIMER

Timer and Batteries

1

To obtain replacement parts, call toll-free 800.626.2002 (U.S.),

C

D

After new batteries are installed or filter is changed, push and hold the timer blue reset button for approximately 5 seconds. Release the reset button after the light flashes 5 times. The light will flash again in 180 days to remind you that it is time to change the filter.

Attach timer to remote location for easy viewing.

800.663.6060 (Canada–English), 800.361.3869 (Canada–French).

GE Consumer & Industrial

Appliances

General Electric Company

Louisville, KY 40225

LIMITED ONE YEAR WARRANTY

What does this warranty cover?

 

How do I make a warranty claim?

— Any defect in materials or workmanship in the manufactured product.

 

 

— Return to the retailer from which it was purchased, along with a copy of the “Proof

What does this warranty not cover?

 

 

of Purchase.” A new or reconditioned unit will be provided. This warranty excludes

 

 

the cost of shipping the product to your home.

— Filter cartridge and batteries after 30 days from date of purchase.

 

 

 

 

 

 

— Service trips to your home to teach you how to use the product.

 

 

 

 

 

 

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is

 

— Improper installation, delivery or maintenance.

 

 

 

 

 

product exchange as provided in this Limited Warranty. Any implied warranties,

 

— Failure of the product if it is abused, misused, altered, used commercially or used

 

 

 

 

 

including the implied warranties of merchantability or fitness for a particular

 

for other than the intended purpose.

 

 

 

 

 

purpose, are limited to one year or the shortest period allowed by law.

 

— Use of this product where water is microbiologically unsafe or of unknown quality,

 

 

 

 

 

 

 

without adequate disinfection before or after the system. Systems certified for cyst

 

 

 

 

 

This warranty is extended to the original purchaser and any succeeding owner for

reduction may be used on disinfected water that may contain filterable cysts.

 

— Damage to the product caused by accident, fire, floods or acts of God.

 

products purchased for home or office use within the USA. In Alaska, the warranty

Incidental or consequential damage caused by possible defects with this

 

excludes the cost of shipping or service to your home or office.

 

Some states do not allow the exclusion or limitation of incidental or consequential

appliance, its installation or repair.

 

 

damages. This warranty gives you specific legal rights, and you may also have other

For how long after the original purchase?

 

 

rights, which vary from state to state. To know what your legal rights are, consult

— One (1) year.

 

your local or state consumer affairs office or your state’s Attorney General.

 

4 Contact us at ge.com, or call toll-free at 800.952.5039 in the U.S., or 866.777.7627 in Canada.

Image 4
Contents Safety Precautions Proper InstallationParts Included Tools YOU will NeedInstallation Instructions Installing the SystemInstall Faucet Adapter Install the HEAD/BRACKETInstall Tubing Cutting the TubingParts List Install Compression FittingsInstall the Batteries Attach timer to remote location for easy viewingInstallation Instructions Instructions D’INSTALLATION Avertissement Éliminez enMesures DE Sécurité Pièces FournisInstructions d’Installation Installation DU SystèmeCoupez L’ALIMENTATION EN EAU Installation DE L’ADAPTATEUR DE RobinetDécoupe DU Tuyau Installation DU Tuyau Installation DES PilesListe DES Pièces Dernière VérificationPage Precauciones DE Seguridad Partes IncluidosHerramientas Necesarias Instalación CorrectaInstrucciones de instalación Instalación DEL SistemaEspecificaciones DEL Cartucho Instrucciones DE Instalación Paso a PasoInstalación DEL Adaptador Para Grifo Desconexión DEL Suministro DE Agua FríaCorte DE LA Tubería Instalación DE LAS Uniones DE Compresión Instalación DE LA TuberíaInstalación DE Pilas Lista DE Partes Control Final