Kenmore 625.38376 Installgroundingclampbetween, Connecting Transformer, Softener in and OUT Pipes

Page 16

INSTALLGROUNDINGCLAMPBETWEEN

THE SOFTENER IN AND OUT PIPES

The house cold water pipe (iron or copper) is often used to ground all electrical outlets in the home. Outlets are grounded to protect you from shock when you touch any electric appliance plugged into the out- let. If you installed the single bypass valve, the cold water pipe ground is broken. See Fig. 20 and 21.

IMPORTANT." Be sure the cold water pipe has direct metal to metal contact all the way to the ground. Plastic, rubber or other electrically insulat- ing parts such as hoses, fittings, washers or gas- kets can break the direct metal to metal contact. Also check the water meter (city water) or the well pump. Install #4 copper jumper wires, clamped tightly on both ends, across insulated parts. See Fig. 21.

To restore the ground, take the ground clamp kit that is in the parts bag. Install across the inlet and outlet cop- per tubes. See Fig. 20. Be sure good contact is made between the pipe and the clamps.

ELECTRICAL POWER OUTLET FOR YOUR SOFTENER

The softener works on 24 volt, 60 Hz electric power. The included transformer changes standard 120 volt AC house power to 24 volts. You must plug the trans- former into a grounded, 120 volt outlet only. Be sure the outlet is always "live" so someone cannot turn it off by mistake. See Fig. 22.

NOTE: The included transformer is made for inside

use only. Be sure the electrical outlet you plug the

transformer into is inside, to protect from weather.

PLUG IN THE TRANSFORMER

Plug the transformer into the electrical outlet.

COLD WATER PiPE GROUNDING

TO

Valve Inlet

Ground

Clamp (2%

Screw with lock "_ washer and nut

FROM

Valve Outlet

FIG. 20

WATER METER JUMPER WiRE

Water Meter

#4 Groundwire

FiG. 21

CONNECTING TRANSFORMER

Transformer

120V-6OHz

Electrical

Outlet

_ From Face Plate-Timer

FiG. 22

Questions? Call The Kenmore Water Line 1-800-426-9345

16

Image 16
Contents Save this Manual Part No Rev. M 4/17/08Three Year Limited Warranty on Electronic Parts Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Table of Contents Facts Figures To KeepPage Small Parts Parts DescriptionsINSPECT Shipment Proper Order to Install Water Treating Equipment PipeWhere to Install the Water Softener Shu -offIIDraw Your Pipes FittingsOUT Pipe or bothBefore iNSTALLiNG Checks & Tests Drain portBypass Valve Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveInlet and Outlet Threaded Adaptors Bypass Valve Turned Downward INSTALLiNG Holding ClipsValve Bypass Move Softener Into Place Typical Soldering Connections Position Softener Into Place Connect the SoftenerConnectthevalvedrainhose Connect Salt Tank Overflow TubingHouse Main Water Shutoff Valves Single BypassLeak Test To check for leaks, complete the following stepsInstallgroundingclampbetween Connecting TransformerElectrical Power Outlet for Your Softener Softener in and OUT PipesInstallcovers Your Plumbing Installation and ElectricalSET Present TiME of DAY SET Water Hardness Number2ppmironx5= Gpg hardness +10 Hardness Number PresenttimeIt draws the bleach Into and through Softener To sani Sanitize Your Water Softener AS FollowsTize it Water Softening Salt with Iron Removing Additives CHECKLiST of STEP-BY-STEP Guides to INSTALL Installed?Are the drain lines clamped and secured? Unit plugged Into a continuously live outlet?Extrarecharge Recharge NOWRecharge Tonight Salt Monitor SystemClean Feature Minutes 97% Feature Maximum Days Between Regen ErationsTank Light Water Flow Through the SoftenerCOl LO MRecharge Time Remaining and Valve Position Indicators Error CodeKenmores Ultra Cleansing Feature Program MemoryWater Flow Through Softener in Service Soft Water Service and RegenerationWater Flow Through Softener in Fill RegenerationWater Flow Through Water Flow Through Softener Brining and Brine RinseSoftener in Backwash Water Flow Through Softener Fast Rinse Soft Water Service and Regeneration Automatic BypassElectronics Salt Bridge Salt BridgeNozzle & Venturi Keeping the Water Softener CleanIron from Resin BED Drain ALL Water from Softener Protect the Water Softener from FreezingProblemcause Checklistto Helpyou Save MoneyCorrection Bypass Valves 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Flow Rate GPM30,000 @ 37,900 @Wiring Schematic FaceplateAlways Make These Initial Checks First Eration CheckPossible Problem Most LikelyTimer PWA Replacement TroubleshootingOther Information Manual Advance Regeneration Check Cycle Flow Rates Gallons PER MINBrine Rinse MAX. BackwashRotaryvalveservice DisassemblyAssembly To Relieve PressureFill Cycle Water Flow Through the Softener ValveBrining and Brine Rinse Cycle Water Flow Through the Softener Valve Backwash CycleFast Rinse Cycle Backwash CycleQuestions? Call The Kenrnore Water Line 1=800=426=9345 Water Softener CompletePart Number PartInlet Outlet Grounding ClampsBrine Valve Assembly Wear-Strip Seal Cross-Section View Key NumberRepair Service Center Repair Carry-in ItemsVacuums Lawn Equipment For Electronics Call anytime For