Kenmore 625.38376 Drain ALL Water from Softener, Protect the Water Softener from Freezing

Page 31

PROTECT THE WATER SOFTENER FROM

FREEZING

If the softener is installed where it could freeze (sum- mer cabin, lake home, etc.), you must drain all water

from it to stop possible freeze damage. To drain the sof- tener:

1.Close the shut-off valve on the house main water pipe, near the water meter or pressure tank.

2.Open a faucet in the soft water pipes to vent pres- sure in the softener.

3.Move the stem in a single bypass valve to bypass. Close the inlet and outlet valve in a 3 valve bypass system, and open the bypass valve. If you want water in the house pipes again, reopen the shut-off valve on the main water pipe.

4.Unplug the transformer at the wall outlet. Remove the salt hole cover and the main cover. Take off both

drain hoses.

5.Carefully remove the large holding clips at the soften- er inlet and outlet. Separate the softener from the

plastic installation adaptors, or from the bypass valve.

6.Remove the brinewell cover and disconnect the brine valve tubing at the nozzle and venturi assembly. Lift the brine valve out of the brinewell. Tip the brine valve upside down to drain water.

7.Lay a piece of 2 inch thick board near the floor drain. Move the softener close to the drain. SLOWLY and CAREFULLY, tip it over until the rim rests on the wood block with the inlet and outlet over the drain. Do not allow the softener's weight to rest on the inlet and outlet fittings or they will break,

8.Tip the bottom of the softener up a few inches and hold until all water has drained. Leave the softener laying like this until you are ready to use it. Plug the inlet and outlet with rags to keep dirt, bugs, etc. out.

DRAIN ALL WATER FROM SOFTENER

Floor Drain

Wood Block

FIG. 56

Questions? Call The Kenmore Water Line 1-800-426-9345

31

Image 31
Contents Part No Rev. M 4/17/08 Save this ManualThree Year Limited Warranty on Electronic Parts Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Facts Figures To Keep Table of ContentsPage Small Parts Parts DescriptionsINSPECT Shipment Pipe Proper Order to Install Water Treating EquipmentShu -offII Where to Install the Water SoftenerFittings Draw Your PipesPipe or both OUTDrain port Before iNSTALLiNG Checks & TestsBypass Valve Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveInlet and Outlet Threaded Adaptors Bypass Valve Turned Downward INSTALLiNG Holding ClipsValve Bypass Connect the Softener Move Softener Into PlaceTypical Soldering Connections Position Softener Into PlaceConnect Salt Tank Overflow Tubing ConnectthevalvedrainhoseTo check for leaks, complete the following steps House Main Water Shutoff ValvesSingle Bypass Leak TestSoftener in and OUT Pipes InstallgroundingclampbetweenConnecting Transformer Electrical Power Outlet for Your SoftenerYour Plumbing Installation and Electrical InstallcoversHardness Number Presenttime SET Present TiME of DAYSET Water Hardness Number 2ppmironx5= Gpg hardness +10It draws the bleach Into and through Softener To sani Sanitize Your Water Softener AS FollowsTize it Water Softening Salt with Iron Removing Additives Unit plugged Into a continuously live outlet? CHECKLiST of STEP-BY-STEP Guides to INSTALLInstalled? Are the drain lines clamped and secured?Salt Monitor System ExtrarechargeRecharge NOW Recharge TonightMaximum Days Between Regen Erations Clean Feature Minutes 97% FeatureLO M Tank LightWater Flow Through the Softener COlProgram Memory Recharge Time Remaining and Valve Position IndicatorsError Code Kenmores Ultra Cleansing FeatureRegeneration Water Flow Through Softener in ServiceSoft Water Service and Regeneration Water Flow Through Softener in FillWater Flow Through Water Flow Through Softener Brining and Brine RinseSoftener in Backwash Water Flow Through Softener Fast Rinse Soft Water Service and Regeneration Automatic Bypass Electronics Salt Bridge Salt BridgeNozzle & Venturi Keeping the Water Softener CleanIron from Resin BED Protect the Water Softener from Freezing Drain ALL Water from SoftenerProblemcause Checklistto Helpyou Save MoneyCorrection Bypass Valves 37,900 @ 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Flow Rate GPM 30,000 @Eration Check Wiring SchematicFaceplate Always Make These Initial Checks FirstMost Likely Possible ProblemTimer PWA Replacement TroubleshootingOther Information MAX. Backwash Manual Advance Regeneration CheckCycle Flow Rates Gallons PER MIN Brine RinseTo Relieve Pressure RotaryvalveserviceDisassembly AssemblyFill Cycle Water Flow Through the Softener ValveBrining and Brine Rinse Cycle Backwash Cycle Water Flow Through the SoftenerValve Backwash Cycle Fast Rinse CycleQuestions? Call The Kenrnore Water Line 1=800=426=9345 Part Water SoftenerComplete Part NumberGrounding Clamps Inlet OutletBrine Valve Assembly Wear-Strip Seal Cross-Section View Number KeyElectronics Call anytime For Repair Service CenterRepair Carry-in Items Vacuums Lawn Equipment For