Set the High Temperature Limit Stop (optional)
Lift the handle (1).
Use a 4 mm Allen wrench to push the screw cover into the handle (2).
Use the 4mm Allen wrench to loosen the handle screw 4 complete revolutions (3).
Remove the handle (4). Retrieve the screw cover. Remove the nut cover.
Turn the stem
Remove the handle screw (1).
Remove the high temperature limit stop (2).
Replace the high temperature limit stop so that the pin on the cartridge is in the desired slot on the limit stop.
Note: the temperatures given in the diagram as- sume a water heater temperature of 140° F, a cold water temperature of 50°F and a water pressure of 45 PSI.
Replace the nut cover (1).
Replace the handle screw. Use the Allen wrench to turn the screw 4 revolutions (2).
Replace the handle (1). Tighten the handle screw (2). Install the screw cover (3).