Hans Grohe 2810BXX1, 28110XX1 Replacement Parts, Check Valve Maintenance Backflow preven

Page 7
Replacement Parts 28108001

Replacement Parts 28108001

1

check valve

94074000

 

2

screw

97598000

 

Check Valve Maintenance: Backflow preven-

1

tion is provided by a check valve, which is integral

to the wall outlet adapter. The check valve should be

2

removed and cleaned yearly.

 



Image 7
Contents Wall Outlet Adapter with Hose Connection Raindance AllrounderInstallation Instructions / Warranty Determining the mounting height Technical DataRaindance Allrounder 28110XX1If you are not using the 28108XX1 wall outlet adapter, go to page Roughing inDo not overtighten, or damage will result InstallationFailure to seal the wall can lead to possible water damage Seal the wall around the anchors with waterproof sealantInstall the handshower Check Valve Maintenance Backflow preven Replacement PartsCorner Mount Kit Do not drill through the mounting plate Install the 28110XX1 AllrounderSeal the wall around the anchors with waterproof sealant Pull or push the Allrounder to the desired position Using the AllrounderTo adjust the handshower height Guide the hose over the hose hookLimescale Removal Raindance E 150 Air 3-Jet HandshowerChange the spray modes Replacement parts Cleaning Instructions for Faucets and Showers Cleaning Recommendation for Hansgrohe ProductsLimited Lifetime Consumer Warranty Cleaning Materials for Faucets and ShowersTHIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR Hansgrohe, Inc. 1490 Bluegrass Lakes Parkway Alpharetta, GA US - Installation Instructions Part No. 90661501 Revised 01/2008Tel. 770-360-9880 Fax