Electrolux E40PV100FS installation instructions Safety

Page 7

Safety 7

CAUTION

To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

Take care when using cleaning agents or detergents.

Avoid using food products that produce flames under the Range Hood.

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors

To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.

For best capture of cooking impurities, the bottom of the hood should be a minimum of 24” and a maximum of 30” above the cooking surface. See “Installing the Support System” section for mounting restrictions.

Two installers are recommended because of the large size and weight of this hood.

This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.

Please read specification label on product for further information and requirements.

Use with approved cord-connection kit only.

Image 7
Contents Use & Care Guide Installation Instructions 877- 4ELECTROLUX Finding InformationRead and Save These Instructions QUESTIONS?Table of Contents Important Safety Instructions SafetySafety Precautions Safety Safety Operating Your Hood Getting StartedAuto-Start Heat Sensing System Halogen Bulbs OperationBulb may be hot Use of a fuse greater than 4 amps may damage the transformer Fuse ReplacementGrease Filters Care and CleaningCleaning the Filters and Hood Hood CleaningInstallation Planning InstallationVerify Package Contents To reduce the risk of fire, use only metal ductwork Installing the DuctworkInstalling the Support System Installation15Requires optional 10-foot flue extension model EXPV100S Installing the Duct Collar Connecting the Decorative FlueMounting the Hood to Support Frame Installing the ElectricalReplacing the Bottom Trim Connecting the DuctworkPrior to use, remove protective film from the filter frame Installing the FiltersIf Service is Required TroubleshootingProblem Possible Cause Remedy Troubleshooting GuideEnergy Saving Tips Saving EnergyPage Hood Warranty Your hood is protected by this warranty Warranty