Emerson operation manual E2 Building Controller BX

Page 18

Capabilities

RX-

RX-

RX-

100

300

400

 

 

 

 

 

ESR8 ESR Control

0

99

99

 

 

 

 

Flexible Combiner

64

128

128

 

 

 

 

Heat/Cool Control

0

16

16

 

 

 

 

Holiday Schedule

4

64

64

 

 

 

 

Impulse

0

48

64

 

 

 

 

Infrared Leak Detection

1

16

16

 

 

 

 

K5 Ref Scroll

0

31

31

 

 

 

 

Logging Group

8

32

32

 

 

 

 

Loop/Sequence Control

4

16

24

 

 

 

 

Modular Chiller Control

0

1

2

 

 

 

 

MultiFlex ESR

0

31

31

 

 

 

 

MRLDS

24

24

24

 

 

 

 

Performance Alert

0

63

63

 

 

 

 

Power Monitoring

1

16

16

 

 

 

 

Pulse Accumulator

0

16

16

 

 

 

 

RMS Asset

99

99

99

 

 

 

 

Standard Circuit

48

48

64

 

 

 

 

Suction Group

4

4

4

 

 

 

 

TD Condenser Fan Con-

4

64

64

trol

 

 

 

 

 

 

 

TD3 Controller

0

99

99

 

 

 

 

Time Schedule

4

64

64

 

 

 

 

Table 1-1- RX-100, RX-300, and RX-400 Comparison

1.2The E2 Building Controller (BX)

The counterpart to the E2 RX is the E2 BX, which con- trols HVAC systems for low-rise retail, industrial, and commercial buildings. The BX’s primary function is to provide energy-efficient control of air handling units

(AHUs), rooftop units (RTUs), and other systems related to environment control. In addition, the BX provides extensive sensor control, logging, and graphing features that allow the user to view accurate real-time information about system conditions. The BX is equipped with many power monitoring and demand control features that give you the information you need to keep your site’s energy consumption low.

The E2 BX is available in two models: the BX-300 and BX-400. The only significant difference between the E2 BX-300 and the E2 BX-400 is the total number of building control devices that may be operated by a single controller. Table 1-2shows the differences between capabilities for the BX-300 and BX-400.

Capabilities

BX-300

BX-400

 

 

 

Advanced Rooftop

32

32

Control

 

 

 

 

 

AHU

6

8

 

 

 

Analog Combiner

128

128

 

 

 

Analog Import Point

64

64

 

 

 

Analog Sensor Control

64

72

 

 

 

Anti-Sweat

16

48

 

 

 

Control Link ACC

16

48

 

 

 

Control Link Case Disp

99

99

 

 

 

Control Link RSC

99

99

 

 

 

Copeland CoreSense

31

31

Communications

 

 

 

 

 

CT Drive

16

16

 

 

 

Demand Control

2

2

 

 

 

Digital Combiner

128

128

 

 

 

Digital Sensor Control

64

72

 

 

 

E2 Alarm Panel

7

7

 

 

 

Energy Meter

30

30

 

 

 

Flexible Combiner

128

128

 

 

 

Heat/Cool Control

16

32

 

 

 

Table 1-2- BX-300 vs. BX-400 Comparison

1-2 E2 RX/BX/CX I&O Manual

026-1614 Rev 4 5-JAN-2013

Image 18
Contents BX HVAC, and CX Convenience Store Controllers Rev 4 5-JAN-2013Page E2 Firmware Version Page Table of Contents Insertion Temperature Probe Inside Temperature SensorOutside Temperature Sensor Product Temperature Probes Humidity Sensors and HumidistatsPlug-InFour-Channel Internal Repeater Board InstallationPlug-In Digital I/O Network Card P/N 1 I/O Board Names and Terminology MultiFlex-Plus + BoardConnecting Sensors to Input Boards Powering Echelon DevicesConfiguring Echelon Devices Power Connection Input Setup in E2Web Services Setting the Time and Date 10-9 10.9Changing Required User Access Levels Specifying Alarm Reporting TypesUsing the Help Key to get Property Help Priority SettingsUsing and Configuring a Setup Screen Clean and Door Switches 11-711.4.12 Wiring 11.4.9 Clean/Wash Mode11.4.11 Fail-Safe Mode Setting Up An Individual Case Controller11.7.7 Economization Enable 11.7.4 Temperature Control11.7.5 Zone Temperature 11.7.2 How Zones WorkConfiguration Setpoint ResetTemperature Differential TD Strategy AlarmsLearning Mode Service Modes11.21.12 Configuration Accessing the Alarm Advisory Log12.10.9 Facility Status Display FSD Alarms 12.10.5 Ack/Reset State12.10.8 Acknowledging, Resetting, and Clearing Log Entries 12.10.2 Viewing the Controller Advisory LogPage Introduction E2 Refrigeration Controller RXE2 Building Controller BX E2 Convenience Store Controller CX Networking Overview 1 E2 I/O NetworkE2 Echelon Lonworks Network Interconnection With Other E2sDocumentation Overview On-Line Help System Overview Software LicensingPage Hardware Overview E2 HardwarePIB LEDs Status 1 E2 Main Processor Board 3 E2 KeypadLEDs PIB LED’s StatusMain Board Status CPU LEDs I/O Network Boards and PeripheralsGateway Board Keyboard StatusMultiFlex Combination Input/ Output Boards MultiFlex BoardsMultiFlex 16 Input Board Gateway ModelModel Description Name MultiFlex Combination Input/Output Board Top ViewMultiFlex Rooftop Control Board RCB BX and CX Only MultiFlex CUBMultiFlex RTU BX and CX Only MultiFlex PAK BoardMultiFlex ESR Board Hand-held Terminal P/N8RO and 8ROSMT Relay Boards RJ-11 to male RJ-11 cable6 4AO Analog Output Board 15- 4AO Analog Output Board P/N16AIe Dis 8ROe DisEC-2s 5 TD3 Temperature Display Facility Status Display FSDStandard Mount MountingMounting the E2 Recessed MountRetrofit Mounting Standard Mount Inside Rear of EnclosureMounting I/O Boards Blank FaceSingle/Double Enclosures Boards Without Enclosures Snap Track 4AO BoardMultiFlex ESR Echelon DevicesCOM3 Internal Modem Plug-In Card P/N 3 TD3Mounting the Two-Channel Repeater Two-Channel and Four- Channel RepeatersMounting Repeaters Overview Mounting the Four-Channel RepeaterSensors Transducers Inside Temperature SensorOutside Temperature Sensor Pressure TransducersMounting Bullet and Pipe Mount Sensors Insertion Temperature ProbeSupply and Return Air Sensors Application Sensor TypeIndoor RH Sensor Product Temperature ProbesHumidity Sensors and Humidistats Outdoor RH SensorsDewpoint Probe Light Level SensorDuct-mounted Insertion RH Probe Liquid Level Sensors Refrigerant Leak DetectorsPage Main Processor Board E2 Hardware SetupSetting up the E2 EnclosurePowering the E2 Add-On E2 Peripherals3 COM3 Internal Modem Plug- In Card P/N Plug-In Digital I/O Network Card P/NLEDs E2 Installation Guide COM Ports Serial Device Software SetupOverview Pre-SetsE2COM# Associations Connector Page Page 1 I/O Board Names and Terminology RS485 Network and Hardware SetupI/O Network Or I/O NetI/O Network Structure Daisy Chains Wiring TypesMultiFlex-Plus + Board Board DesignationSetting the Baud Rate Network Noise MinimizationNetwork ID Numbers Board Numbers Setting the Terminating and Biasing Jumpers Powering the I/O BoardsWiring Types Control Techniques Drive Board InstallationIMC/Prodigy Rooftop Unit Controllers 14 AWGEnergy Meter 3 XR35CX, XR75CX, XEV22 Case ControllersIPro DAC 3.1 XR75CX-Case DisplayCopeland Discus with CoreSense Protection Supported System TypesAdvisory and Alarms Light Commercial ThermostatThermostat Inputs Comfort Alert Descriptions Cause E2 Advisory Refrigerant Leak Detection System Rlds High/Low Occ/Unocc Space Temperature AlarmsSupply Sensor Fail Alarm Conditions for Return to Normal RTN on Diag- nostic Codes12.1 XM670 Diagnostic AlarmsXM Series of Case Controllers 12.2 XM679BACnet Communication BACnetBACnet Overview Master Slave Token PassingDiscovery 3 MS/TP Network Connection To E2BACnet IP Internet Protocol Client-ServerRescan 13- Commissioning Screen16 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Multiflex Combination I/O Board Installation Guide 18 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 BACnet 20 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 16AI Installation Guide MultiFlex ESR Installation Guide BACnet 24 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Page Page Equipment Type Specifications Ethernet IP ConfigurationsHardware Specifications E2 Ethernet Peer CommunicationsEthernet Network Layouts Closed Network LayoutOpen Network Layout Open Network LayoutTroubleshooting Peer Network Tab Set Group NameEchelon Network Cable Specifications Echelon Network and Hardware SetupWiring Type Cable Type Emerson Retail Solutions Part NumberDevice Termination Maximum Number of Echelon DevicesPowering Echelon Devices Wire RestrictionsInstalling Echelon Devices Maximum Total Segment LengthRed Service Configuring Echelon DevicesEchelon Board Status Red D1 Reset LEDsTroubleshooting Connected/IO Setup Screen RX Unit ShownE2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 One pin when unterminating an E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Sensor Wiring Types Input and Output SetupWiring Input Type Dip SwitchesPower Connection Input Type Dip Switches for MultiFlex 16 and 16AI BoardsSensor Input Type Wiring Dip Switch DownWall-mounted Down Down LevelInput Setup in E2 Application Using the Input Definitions/ Status ScreenSetting Up Analog Inputs AssociationSensor Type Description Per Pulse onSetting Up Digital Inputs Digital Input ScreenWiring Form C Contacts 8RO, 8IO, and MultiFlex OutputsMultiFlex Relay Outputs Output Board Fail-Safe and Switch Settings Setting the Fail-Safe Dip SwitchRelay Output Test Mode Board Type VersionOutput LED Wiring Outputs to PointsOutput Setup in E2 Old 8ROsUsing the Output Definitions/ Status Screen Setting Up Digital OutputsSetting Up Analog Outputs 12- Digital Output Screen13- Analog Output Screen CC-100 Case Controllers InputsPower Module Wiring Valve Cable335-3263 Pulse Valve ESR8 Boards Dis CCB Case Controllers335-3260 to Valve Connection Information MultiFlex ESR BoardESR8 and MultiFlex ESR Valve Output Wiring Page Quick Start Cleaning Out the ControllerPerforming a Clean Out Logging OnSetting Number of Network Devices Boards on the I/O NetworkUnit Controllers Echelon Setting Number of Applications Customizing the Home ScreenFunction Keys Common Screen ElementsHeader Help LineStatus Screens Screen TypesMain Menu Key Function for RXActions Menu Item Description Setup ScreensActions Menu Actions Menu Options and DescriptionsSystem Configuration Menu System Configuration Menu OptionsMenu Option Description System Information Menu System Information Menu OptionsTime/Date Setup Setting the Time and DateSet Up Modem Set Up TCP/IP 17- TCP/IP AddressingSet Up Network Baud Rates 10.11.1 COM1 Serial RS232 Baud Rate10.11.2 I/O Network Baud Rate Set Up User Access User Access LevelsLevel Changing Required User Access Levels Creating a New User AccountDeleting a User Set Up I/O Network Specify Number of BoardsChecking Online Status Set Up Echelon Network Specifying Number DevicesCommissioning a Device Modbus Commissioning Service Button MethodHow Echelon Commissioning Works Network CommissioningESR8’s Service Button CC-100’s Service ButtonTD3’s Service Button Manual ID Entry MethodLicense Management 31- Commissioning MenuSet Up Alarming Web ServicesEchelon Network Alarm Annunciator Specifying Alarm Reporting TypesAlarm Output Display LineSetting up an E2 to be an Alarm Annunciator Alarm Dial-OutSet Alarm Annunc field to Yes Set Up Global Data Introduction Alarm ReportingPriority Settings 10-24 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013Set Up Applications Example Setting Up an Outdoor Temperature Sen- sorAdd an Application Using and Configuring a Setup Screen10.18.1 Add/Delete an Application Delete an ApplicationNavigating the Setup Screen Edit MenuEntering Setpoints Index Tabs Function Keys For SetupFunction Keys for Setup Screens Help LineUsing the Help Key to get Property Help Page Introduction Software OverviewSuction Groups Standard Suction Group ApplicationCircuit Load Analysis Learning ModeHardware Overview Control/Cycles ParameterCondenser Control Temperature Differential StrategyInput Sensor Type Wiring Instructions Air Cooled CondensersEvaporative Condensers Condenser Split ModeFast Recovery Fan ControlStandard Circuits Evaporative CondenserRefrigeration Control Defrost ControlDefrost Termination Clean and Door SwitchesClean Switches Emergency DefrostDoor Switches TD3 Temperature DisplayWiring Control Link CD Case DisplayTypical Case in a Standard Circuit Case Control Circuits OverviewValve Control EEVs Liquid Pulse and Liquid StepperEEPRs Suction Stepper Thermostatic Expansion Valves TXVsOff Cycle Timed Demand Defrost Temperature TerminationAnti-Sweat Control Wait StateLight Control Clean/Wash ModeDual Temp Control Dewpoint Input SourcesFail-Safe Mode Recoverable Sensor FailuresWalk-In Freezer Control Setting Up An Individual Case Controller Logging GroupsBase Log Group Possible Data ErrorsData Compression ClippingSetting Up Logging Logging Setup MenuLogging Group Report Logging Group Status ScreenLog Reports Application Log ReportAlternate Setpoints Temperature ControlAir Handling Units System Log ReportSingle-Speed Fans Two-Speed FansVariable-Speed Fans Analog Economizer Control Economizer ControlDigital Economizer Control Dehumidification ControlCurtailment Optimum Start/Stop OSSIntelligent Pre-Starts and Pre-Stops Separate Setpoints AHU Zone ControlHow Zones Work Output Device Wire 8RO contacts Set Fail-safe Dip Switch toZone Control 11- Suction Group OutputsMultiFlex RCB Board Applications That May Be Connected To ZonesMultiFlex RTU Board MultiFlex RCB-P BoardZone Temperature Economization EnableAHUs Effect of Enabling Economization Zone Humidity Input Effect of Enabling DehumidificationMultiFlex RTUs and RCBs 17- Diagram of Pre-Start and Pre-Stop Operation Stand-Alone MultiFlex RTUs MultiFlex CUB BoardLosing Contact With Zone Applications MultiFlex RTU/ARTC and AHU Zone AssociationMultiFlex PAK Board Lighting SchedulesStandard Control Functions of the Lighting Schedule ApplicationControl Method Select Light Level Interface CellAlternate Control Schedule Interface CellMulti-Logic Combiner Proof Cell Basic Schedule CellMin ON/OFF Cell Offset Solar ControlIntroduction to Demand Limit Control Demand ControlOutput Light Dimming Demand MonitoringPriority Levels Load SheddingShedding Levels DefinitionRotational Shed Last ShedOther Notes About Priority Levels Mode 1 KW Input Is Greater Than Setpoint Mode 3 Integral Error Approaching ZeroHow Demand Control Uses Load Shedding Sensor Control Power Monitoring InputSettings Analog Sensor ControlDigital Sensor Control Logical CombinationControl Cells Output Cells DiagramLoop/Sequence Control Cell Descriptions Select CellOutput Cell Descriptions PWM Cell Time Scheduling and HolidaysHow Schedules Work EventsTemporary Schedule Events Power MonitoringHoliday Schedules OverlappingDaily LoggingHourly MonthlyAnti-Sweat Setup Heat/Cool ControlHow Anti-Sweat Works Setpoint Reset Unoccupied HysteresisAnalog and Digital Combiners Lead/LagTD Control Temperature Differential TD StrategyConfiguration TD Control Fail-SafesAlarms Pulse AccumulationOutputs High Trip Accumulator Reset TypesIrrigation Control Zones and CyclesCycle Scheduling Zone InhibitZone Bypass Inputs Service Modes Flow Sensor-Related TestsTwo Speed Fan Control Flexible Combiner Modular Chiller Control MCCLearning Mode Compressor ControlDigital Scroll Compressor BoilerBypass Valve Control Variable Frequency Drive CompressorLog Information RMS AssetRMS Scale Device ConstraintsLogged Changes Unlogged ChangesPage Page BX Home Screen Operator’s Guide to Using the E2E2 Home Screen RX Home ScreenLogging On and Access Levels CX Home ScreenNavigation System Configuration MenuToggling Full Options MenusPress System Configuration Press System Information System Information MenuSummary Screens Screen TypesActions Menu Status ScreensSetup Screens Index TabsHeader Icons Tab Key E2 KeypadCursor Enter KeyUp/Page Down Keys Log In/Out KeyFour Directional Arrow Keys Ctrl Page Up/Ctrl Page Down KeysManual Defrost and Clean Mode Customizing the Home ScreenList menu and choose End Manual Mode OverridesChecking Boards Online Checking Status Screens Viewing the Controller Advisory Log AlarmsAccessing the Alarm Advi Sory Log Date and TimeArea Ctrl Application Property 12.10.5 Ack/Reset StateAlarm States Advisory MessageResetting ClearingLocating Logged Inputs Outputs Facility Status Display FSD AlarmsViewing Logs and Graphs Home/Status ScreensSetup Screens Setting Up Input and Output PointersLog View Graph View Zooming In and OutMultiple Languages Appendix a Case Type Defaults High Alarm, Low Alarm, and DelayDefrost Type Hdbx Eclipse Transducers Voltage Pressure PSI Table B-1- Temp Sensor Temperature/Resistance ChartTable B-2- Eclipse Voltage to Pressure Chart 100 lb 200 lb 500 lb XducerPage Appendix C Alarm Advisory Messages Alarm Name Default Definition PriorityE2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Appendix C Alarm Advisory Messages C-3 Alarm Name Default Definition Priority Appendix C Alarm Advisory Messages C-5 Alarm Name Default Definition Priority Appendix C Alarm Advisory Messages C-7 Alarm Name Default Definition Priority Appendix C Alarm Advisory Messages C-9 10 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Appendix C Alarm Advisory Messages C-11 12 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 RAM 14 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Copeland CoreSense E2 Alarms ISD 2.0/2.1 CoreSense DiagnosticsNo 3PHASE PWR Performance Alert CoreSense Diagnostics CoreSense DeviceOther Advisories Discus P470 CoreSense Protection K5 Ref Scroll P510 Copeland Scroll CoreSense CommP47 CoreSense Comm Proportional P Mode Appendix D PID ControlThrottling Range Proportional Constant Kp Integral ModeWhy I Mode is Necessary Throttling Range on page D-1Derivative Mode I Mode CalculationSaturation Output at Setpoint D Mode CalculationHow Condenser Control Hvac PID Differs From Others Output at Setpoint for Non-CondenserOutput at Minimum / Output at Maximum Other PID FeaturesChanging the Output at Setpoint Output at Setpoint for Condenser/HVAC PID ControlMinimum Accumulated Error FilteringPage Page Medium Resolution Reuccf Page Page Appendix F Troubleshooting Refer to .1.9, PoweringEchelon Network Appendix F Troubleshooting F-3 Symptom Possible Problem Solution Number of Fans field? TripSymptom Possible Problem Solution Appendix F Troubleshooting F-7 Figured as an analog input Page Page Appendix G Revision Log Page Index NumericsBlue R. See Cold Reset Wash mode. See Clean Mode Demand Defrost. See Defrost, demand Hot Gas Defrost. See Defrost, hot gas Tion Probe LonWorks Network. See Echelon Network Pmac Hansen probe. See Sensors, liquid level 10 E2 RX/BX/CX I&O Manual Rev 4 5-JAN-2013 Valves