Viking 15" W installation instructions Water Connection, Water Supply

Page 10

WATER CONNECTION

 

REAROFUNIT

 

GARDENHOSE

 

FITTING

5/8" (.63 cm) I.D. DRAIN

 

TUBINGBARB

 

MAKE CERTAIN ALL HOSE

5 1/2" (14.0 cm)

CLAMPS ARE SECURE

 

 

2 1/8" (5.4 cm)

COMPRESSIONFITTING

1/4" (.64 cm) TUBING FROM COLD WATER LINE

Water Supply

•This ice machine must be connected to a potable, active cold water supply line delivering water pressure at a minimum pressure of 20 psi and maximum of 120 psi.

•Water connection is made through a 1/4” (.64 cm) compression right angle garden hose fitting. Do not use any thread sealers. NOTE: The water line fitting supplied with your ice machine is to be used on a 1/4” (.64 cm) copper water supply line only. Do not attach a plastic supply line to your unit using this fitting.

Fitting valve

Rubber washer

 

Adapter

 

 

 

1/4” (.64 cm) copper water supply line (supplied by customer)

Compression fitting

From water supply to ice machine

Compression nut

•A water filter is recommended for this unit. A quality filter can remove particles as well as remove taste and odors from water. •Do not use a reverse osmosis water filtration system with the ice machine.

•Softened water is not recommended. This will produce mushy, cloudy ice cubes that will stick together. •De-ionized water is not recommended. This water will not form solid ice cubes.

•A water specialist can recommend proper water treatment.

•After installation of water line, turn on water and check for any leaks. Additional tightening may be needed. Do not use any type of thread sealer.

•Allow extra water line for easy removal of unit and to help prevent the water line from kinking.

10

Image 10
Contents Important Please Read and Follow For Your SafetyProper Disposal of Your OLD Refrigeration Product Unpack General InformationUndercounter Cabinet Cutout Area RequirementsProfessional Models Vuim SPECIFICATIONS/DIMENSIONSFront View Side ViewDfim SPECIFICATIONS/DIMENSIONS Designer ModelDuim 37 9/16 95.4 cm 22 55.9 cm 24 5/8 62.6 cm 25 5/8 65.1 cmFull Overlay Panel Installation Bottom View of Door with Left Hand SwingSelecting and Preparing the Overlay Panel Dfim Models 14 3/4 37.5 cm 15/16 22.7 cm TYP 13/16 14.8 cmHinge Hardware Installation Details Attaching the Overlay Panel to the DoorLEG Leveler Installation Read Before Installing LEG Levelers Wiring Diagram Undercounter 15 W. ICE Machine Electrical ConnectionWater Connection Water SupplyDrain Pump Drain PlumbingGravity Drain Gravity Drain Location Model Number VUIM-DPIce Machine Safety and Operation Tips ICE Machine FeaturesHOW the ICE Machine Works Cleaning and Maintenance Using Your ICE MachineOutdoor Use Cleaning the ICE Machine System Troubleshooting Guide Preparing the ICE Machine for StorageOr Clean position Ice machine selector switch isSelector switch is in the OFF Room and/or water temperatureLess than 1/2 thick Room temperature is too warmIce cubes are too small Low ice consumption Not enough water in reservoirAdjusting Grid cutter is not cutting Selector switch is notRoom temperature is too cold Low ice production. Unit Low water level in reservoirService Information Final PreparationUNDERCOUNTER/FREESTANDING ICE Machine Warranty Units certified for Indoor UseUnits certified for Outdoor Use