KitchenAid Slide-out Vent Hood installation instructions Before you start, Metal snips

Page 2

Before you start...

Your safety and the safety of

others is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill

or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:

DANGER

You can be killed or seriously injured if you don’t immediately follow instructions.

WARNING

You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

Important: Observe all governing codes and ordinances.

Proper installation is your responsibility.

Have a qualified technician install the range hood.

Comply with installation clearances specified on the model/serial rating plate.

Model/serial rating plate is located behind the left filter on rear wall of the vent hood.

Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult your cooktop/range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See “Electrical requirements.”

This vent hood is factory set for venting through the roof or wall. For non-vented (recirculating) installations, non-vented (recirculating) kit, Part No. 883140 is available from your dealer or authorized parts distributor.

WARNING — TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable Codes and Standards, including Fire Rated Construction. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

WARNING — To reduce the risk of fire, use only metal ductwork.

This unit must be grounded.

Tools needed:

leveldrill

1-1/4" drill bit

3/8" (8mm) nut driver or ratchet

pliers

pencil

wire stripper or utility knife

gloves

measuring tape

Parts supplied for installation:

2 screws

damper

plastic cover (used for customized front panel)

Parts needed for installation:

wood filler strips for cabinets with recessed bottoms (step 5, page 5)

2, 1" x 1" x 5" (25.4 x 25.4 x 127 mm) wood pieces – optional (step 10, page 6)

2, 1/2" (12.7 mm) U.L.- or C.S.A.-listed conduit connectors

1 wall cap for interior-mounted motor

metal vent system

4, 1-1/4" (31.8 mm) wood screws

power supply cable

caulking gun and weatherproof caulking compound

saber or keyhole saw

duct tape

flat-blade

screwdriver

metal snips

Phillips screwdriver

safety glasses

2

Image 2 Contents
Installation Instructions Use and Care Guide Before you start Metal snipsElectrical requirements Product dimensionsVent Hood Must be Connected with Copper Wire only 30 76.2 cm model 8 20.3 cm 36 91.4 cm model 11 27.9 cm4 x 10 8.3 cm x 25 cm Vent system Wall ventingRoof venting Maximum length = 26 ftNon-vented recirculating Kit, Part No must be used To wire through top wiring Mounting bracket Screw Adjustment screwsFor the Kwvu and Ykwvu model series FilterUse and Care Information For GZ or YGZ model seriesAccessories Vent System Warranty ONE-YEAR Full WarrantyOur consultants provide assistance with Requesting Assistance or Service in U.S.ARequesting Assistance or Service in Canada Panneau avant personnalisé Étapes de l’installationPages Information dutilisationPince à dénuder Vis Volet de réglageNiveau PhillipsDimensions du produit Alimentation électriqueDécharge dans la pièce recyclage à travers le soffite Décharge à travers le toitConduit de 8,3 x 25 cm 4 x 10 po 10 3/4 po Axe central Cales de bois27,3 cm Ouverture àBride de Opercules arrachables pour passage du câblageCouvercle de la boîte De connexion Fond du Montage Placard HottePanneau avant personnalisé Pour modèles des séries Kwvu et YkwvuPour modèles des séries GZ et YGZ 37,3 mm 15/32 po Tableau de Commande couvercle de plastiqueInformation d’utilisation et entretien Surface frontale du panneauAccessoires Garantie du système de ventilation Garantie Complète DE UN AN’exception de l’indicatif régional Demande d’assistance ou de service au CanadaSuccursales de service direct Et l’indicatif régional 807 en Ontario