KitchenAid LI3Y9B/W10320584E Installation Instructions, Electrical Requirements, Prepare Location

Page 6

Example Vent System

90 elbow

 

 

 

 

 

 

Wall cap

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2ft

(0.6 m)

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

1

- 90° elbow

= 5.0 ft (1.5 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

Length of system

= 13.0 ft (3.9 m)

Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

It is recommended that the vent system be installed before hood is installed.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Check your ceiling height and the hood height maximum before you select your hood.

1.Disconnect power.

2.Determine which venting method to use: roof, wall, or non- vented.

3.Select a flat surface for assembling the range hood. Place covering over that surface.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to do so can result in back or other injury.

4.Using 2 or more people, lift range hood onto covered surface.

Range Hood Mounting Screws Installation

1.Determine and mark the centerline on the wall where the canopy hood will be installed.

2.Select a mounting height between a minimum of 24"

(61.0 cm) for an electric cooking surface, a minimum of 27" (68.6 cm) for a gas cooking surface, and a suggested maximum of 36" (91.4 cm) above the range to the bottom of the hood. Mark a reference line on the wall.

3.Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall.

A

DRILL2 (TW O)3/16"PILOTHOLESTHROUGH STUDSOR REAR W ALLSUPPORT

Vertical

 

Centerline

REAR W ALL

 

M OUNTING TEM PLATE

C

L

ALIGN BOTTOM EDGE

W ITH PENCILLINE

INDICATING BOTTOM

OFTHEHOOD

Installation Height

HorizontalLine

BC

A.Centerline

B.Fastener locations

C.Mounting height reference (hood bottom line)

6

Image 6
Contents WALL-MOUNT Canopy Range Hood Table of Contents Range Hood SafetyTable DES Matières Tools and Parts Installation Requirements For Vented Installations, You Will Also Need Tools NeededCabinet Dimensions For Mobile Home InstallationsProduct Dimensions Location RequirementsVenting Requirements Electrical Requirements Installation InstructionsRange Hood Mounting Screws Installation Prepare LocationFor vented installations only Install Range HoodVent Cover Bracket Installation Connect Vent SystemMake Electrical Connection Install Vent Covers Complete InstallationRange Hood USE Light TimerDisplay Fan SpeedCleaning Range Hood CareWiring Diagram Motor SpecificationsU.S.A Assistance or ServiceAccessories CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences D’INSTALLATION Exigences d’emplacementOutils et pièces Exigences concernant l’évacuation Dimensions du placardInstallations pour régions à climat froid Air d’appointDécharge par larrière Installation sans décharge à l’extérieur recyclageSpécifications électriques Exemple de système de déchargeInstallation des vis de montage de la hotte Instructions D’INSTALLATIONPréparation de l’emplacement Installation de la bride de cache-conduitInstallation de la hotte Raccordement du circuit d’évacuationRaccordement électrique Utilisation DE LA Hotte Installation des cache-conduitsAchever l’installation AffichageÉclairage MinuterieBoutons de vitesse du ventilateur Entretien DE LA Hotte NettoyageSchéma DE Câblage Caractéristiques du moteurAssistance OU Service AccessoiresAu Canada Garantie DU Système DE Ventilation Kitchenaid La présente garantie limitée ne couvre pasW10320584E