IX. NV-RC1 REMOTE CONTROL

All NUVO products come with the wireless remote. This remote will control all functions of the NV-EKP keypad. To control the E Series, move the “Device Selector” switch on the upper right side of the RC1 to “Multi-room.” Now the numeric buttons will select the source (#1-#6), and the five buttons in the “Multi-room” section will correspond exactly to the EKP keypad.

The RC1 can also be used to teach any learning remote control all of its internal commands (Fig. 13).

Fig. 13: NV-RC1 Remote

Source

 

Source

 

Source

 

 

 

4

1

TUNER TUNER

TUNER

7

 

4

 

1

2 3

1

Source

5

Source

2

Source

 

 

 

8

 

5

 

2

 

 

 

Source 9

6

Source 6

3

Source 3

MULTI-ROOM

TUNER

NV-RC1 Remote

Learning Remote

Refer to the owner’s manual for your learning remote control to place that device in learn mode. Once you have chosen a page for storing the E Series’ internal functions, i.e., source selection, volume, etc., you can then easily teach these functions to your learning remote and have complete wireless control of your NUVO system.

X. Using the “Mute” and “Unit On” Pins

The “Mute” input can be used to mute the system by providing a dry closure to these pins (Fig. 14). In other

words, any short-circuit across this input will temporarily

mute the system. This can be useful for providing a mute

Fig. 15: “Mute In” and “Unit On” Pins

DIAGNOSTIC CONTROL

REFER TO MANUAL

MUTE UNIT ON

when the phone, or doorbell ring. Most home automation devices can provide this type of output.

0 1 2 3

N.O. G +12V G

-INPUT- -OUTPUT-

The “Unit On” pins will provide a +12Vdc at 100mA output

when any zone is “ON.” This can be used via a signal-

sensing power strip to switch on other equipment when

the E Series system is being used.

The “Mute ” is an external mute switch. This can be as simple as a 2-conductor wire from a relay closure on a home automation system or phone system to the E6M unit. This will short-circuit the input, and mute the system when the doorbell or phone is rung.

Page 12

Image 14
Contents Series NV-E6MS/NV-E6XS Nuvo Technologies Inc NV-E6MS Main Audio Distribution System Description NV-E6XS Expander Audio Distribution System DescriptionSeries Amplifier Front Series Amplifier Back Panel 3 4 5Series Keypad Nuvo RC1 Remote Control IR EmitterInstalling and Terminating Cables Pin #Cat-5 cables from keypads II. Installing the E-Z Port HubIII. Connecting the E6M to the E-Z Port Connecting the IR Emitters IV. Attaching Source Equipment to the E6ME6M Amplifier VI. Connecting the E6M to the E6XVII. Installing the NV-EKP Keypads NV-DI3 Datalink Cable NV-AI2 Audiolink CableVIII. Setting the NV-EKP DIP Switches DIP switches ZoneSwitches 5 & 6, Zone EQ Presets +4dB Boost At 100Hz At 10kHz +4dB Boost At 100Hz and 10kHz Flat ResponseUsing the Mute and Unit On Pins NV-RC1 Remote Learning RemoteXI. MPU Diagnostic LEDs MI1 is not supplied with the E6M or the E6X packages XII. Changing the Buttons on the NV-EKPXIII. NV-MI1 Mute Interface Troubleshooting Symptom Probable CauseNuvo NV-E6M Specifications WarrantyDelhi Pike, Cincinnati, OH USA