Nuvo NV-E6XS, NV-E6MS II. Installing the E-Z Port Hub, III. Connecting the E6M to the E-Z Port

Page 9

II. Installing the E-Z Port Hub

The location of the E-Z Port is mostly determined by where Fig. 2: E-Z Port Backside you locate the E6M amplifier. All Cat-5 cables should be

terminated and routed to this location. Once this is done,

installation of the E-Z Port is easy.

Plug each of the keypad cables into one of fifteen available jacks on the back of the E-Z Port (Fig. 2). The jacks are numbered 1-15, although order is not important to the system’s operation.

Once all the Cat-5 cables are plugged into the E-Z Port, it can then be easily mounted into any commercially available dual-gang J-box or mud ring.

Cat-5 cables from keypads.

III. Connecting the E6M to the E-Z Port

Once you have installed the E-Z Port, connect it to the E6M using the supplied 10 ft. Cat-5 cable supplied with the package (Fig. 3).

Both RJ45 connectors are wired identically with the 568A wiring scheme, so either end is connected to the E-Z Port, with the opposite end connecting to the “Network Input” on the back of

Fig. 3: Network Input

AUDIO OUTPUT

IR EMITTER OUTPUTS

 

NETWORK

 

CONNECT TO NV-E6X

+12V OUTPUT PULSE

CONNECT TO

ODD NUMBERED OUTPUTS ARE IDENTICAL (TIED TOGETHER)

 

NV-EZP

 

 

 

 

 

EVEN NUMBERED OUTPUTS ARE IDENTICAL (TIED TOGETHER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 SUM

DIGITAL OUTPUT

CONNECT TO

NV-E6X

the E6M.

If the supplied network cable is too short or too long, you can make your own using the 568A wiring scheme outlined in Fig. 1, page 6.

NV-NC1 Network Cable attaches

the E-Z Port to the E6M

E-Z Port Face Plate

Page 7

Image 9
Contents Series NV-E6MS/NV-E6XS Nuvo Technologies Inc NV-E6XS Expander Audio Distribution System Description NV-E6MS Main Audio Distribution System DescriptionSeries Amplifier Front 3 4 5 Series Amplifier Back PanelSeries Keypad IR Emitter Nuvo RC1 Remote ControlPin # Installing and Terminating CablesII. Installing the E-Z Port Hub III. Connecting the E6M to the E-Z PortCat-5 cables from keypads IV. Attaching Source Equipment to the E6M Connecting the IR EmittersVII. Installing the NV-EKP Keypads VI. Connecting the E6M to the E6XE6M Amplifier NV-DI3 Datalink Cable NV-AI2 Audiolink CableDIP switches Zone VIII. Setting the NV-EKP DIP Switches+4dB Boost At 100Hz and 10kHz Flat Response Switches 5 & 6, Zone EQ Presets +4dB Boost At 100Hz At 10kHzNV-RC1 Remote Learning Remote Using the Mute and Unit On PinsXI. MPU Diagnostic LEDs XII. Changing the Buttons on the NV-EKP XIII. NV-MI1 Mute InterfaceMI1 is not supplied with the E6M or the E6X packages Symptom Probable Cause TroubleshootingWarranty Nuvo NV-E6M SpecificationsDelhi Pike, Cincinnati, OH USA